This manual covers the following models:TH2110DV: For 1 Heat/1 Cool systemsTH2210DV: For 2 Heat/1 Cool heat pump systems only (Pull thermostat from wallplate and turn over to find model number.)
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
Need Help?For assistance with this product please visit Honeywellhome.com/supportRead and save these instructions.
This thermostat is ready to go!Your new thermostat is preprogrammed and ready to go. See page 9 to check settings.
About your new thermostat
Your new Honeywell thermostat has been designed to give you many years of reliable service and easy-to-use, push-button climate control.
Features
Backlit display is easy to read
Displays ambient (measured) temperature at all times
One-touch access to setpoint temperature
Preset program settings
Temporary and permanent override of schedule
Early start ensures the right temperature at the right time
Built-in compressor protection
This thermostat is ready to go!Your new thermostat is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed:
Set time and day (required for proper operation) ……………. See page 6
Select system setting: Preset to Off…………………….. To change, see page 7
Select fan setting: Preset to Auto………………………… To change, see page 8
Program schedules: Preset to energy-saving levelswhile you’re at work or asleep ………………………… To change, see pages 9-11
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 12-13).
Quick reference to controls
Quick reference to display screen
Set the time and day
Press the SET button, then press to set the clock time.
Press the SET button, then press to select the day of the week.
Press RUN to save & exit.Note: If the clock flashes, the thermostat will follow your settings for the Monday “Wake” time period until you reset the time and day.
Select the system setting
The SYSTEM switch can be set to control your heating or cooling system, depending on the season.
Cool: Cooling system control.
Off: All systems are off.
Heat: Heating system control.
Em Heat: Emergency & Auxiliary Heat control. Compressor is locked out. (Select models only.)
CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
Select the fan setting
Set the FAN switch to Auto or On.In “Auto” mode (the most commonly used setting), the fan runs only when the heating or cooling system is on.If set to “On,” the fan runs continuously.
Save money by setting program schedules
It’s easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays and weekends.
Set to the time you awaken and the temperature you wantduring the morning, until you leave for the day.
Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level).
Set to the time you return home and the temperature you want during the evening, until bedtime.
Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).
Energy saving settings for maximum cost savings
This thermostat is pre-set to use energy saving program settings. We recommend these settings, since they can reduce your heating/cooling expenses. (See next page to adjust times and temperatures of each time period.)
To adjust program schedules
Press SET until Set Schedule is displayed.
Press to set your weekdayWake time (Mo-Fr), then press SET.
Press to set the temperature for this time period, then press SET.
Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
Press SET to set weekend time periods (Sa & Su), then press RUN to save & exit.Note: Make sure the thermostat is set to the system you want to program (Heat or Cool).
Program schedule override (temporary)
Press to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period.“Temporary” will appear on the display and the current program period will flash.The new temperature will be maintained only until the next programmed time period begins (see page 9).To cancel the temporary setting at any time, press RUN.Note: Make sure the thermostat is set to the system you want to control (heat or cool).
Program schedule override (permanent)
Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods.The “Hold” feature turns off the program schedule and allows you to adjust the thermostat manually, as needed.Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press RUN to cancel “Hold” and resume the program schedule.Note: Make sure the thermostat is set to the system you want to control (heat or cool).
Built-in compressor protection
This feature helps prevent damage to the compressor in your air conditioning or heat pump system.Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait 5 minutes before restarting.During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump model). When the safe wait time has elapsed, the message stops flashing and the compressor turns on.
Early Start
Early Start: This feature allows the heating or cooling to turn on before the program start time, so the temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The next time period is displayed when the system is activated before a scheduled time period.
Battery replacement
Install two fresh AAA batteries when Lo Batt flashes on the screen. Lo Batt appears for 60 days before the batteries are depleted.Replace batteries once a year, or when you will be away for more than a month.Most settings are stored in non-volatile (permanent) memory. Only the clock and the day must be set after you replace the batteries.
CAUTION: ELECTRONIC WASTE NOTICE. The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health.