Compatible with 24-230V on/off and OpenTherm® appliances such as gas boilers, combi-boilers and heat pump. Also works with zone valve applications but not with electric heating (240V).
Turn OFF the power and remove the old thermostat
To ensure your safety, always make sure mains power is switched OFF before accessing wiring.
Before removing the old thermostat take a picture of the old thermostat’s wiring as reference then proceed to installation.
The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 – 1.5 meters from the floor.
Maximum cable length between Receiver box and thermostat:15m for 0.5mm² cable or 20m for 1.0mm² cable.
Must be installed by a competent person!Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.
Prepare Receiver Box for installation
Before installation of the Receiver Box
Find a suitable location near to the boiler.
Loosen the front screw to remove cover or tighten it when the cover is back in place.
Needed during installation:
Cable with 2 wires from the Receiver Box (R4H810A) to thermostat.
Cable with 2 wires from the boiler to Receiver Box.
The Receiver Box requires 230V power
Install the Receiver Box
Please refer to the wiring diagrams over the page
Wall box or Rear WiringHinge open the terminal block flap to access the cables and wall box screw holes.
Surface wiringUse the cable clamps to secure the surface wiring.
Replace the coverLocate the hinges at the top of the cover and wall plate, close the cover and secure with the screw.
Install the T6 thermostat
Remember to use the same wires that you connected to the Receiver Box when connecting to the thermostat.
Using a screwdriver open wallplate terminal cover to connect wires
Connect 2 thermostat wires to the T and T terminals and close cover.
Attach the thermostat to the wallplate when finished.
Complete installation
Turn ON mains power to the Heating Appliance and Receiver Box.
After power up, SETUP is displayed on the thermostat’s screen.
Set Up and configuration
Touch to begin setting up the thermostat.
Select your language
Set the clock format, time and date.
Touch to finalise setup. ( to setup using the App is currently unsupported)
Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds.
In the advanced menu the following settings can be adjusted:
Menu Item
Default
Options
LANGUAGE
English
0 = English, 1 = Français, 2 = Español 3 = Deutsch, 4 = Nederlands, 5 = Italiano
OPENTHERM
–
OpenTherm boiler data when available
CYCLE RATE
6
3, 6, 9 or 12
MINIMUM ON TIME
1 minute
1, 2, 3, 4 or 5 minutes
HEAT RANGE
Min = 5.0ºCMax = 35.0ºC
Min: 5ºC to 21ºC, Max: 21ºC to 35ºC
SCHEDULE OPTIONS
Daily
1 = Daily schedule, 2 = 5+2 days schedule
EXTERNAL SENSOR
No sensor
0 = No sensor, 1 = Room sensor
OPTIMISE
Opt. start OFFOpt. stop OFF
Opt. start: 0 = OFF, 1 = ON, 2 = Delayed startOpt. stop: 0 = OFF, 1 = ON
CLOCK
Format: 24hTime: –:–Date: 01/09/16
Clock format: 1 = 12h, 2 = 24hSetup time and date
LOW LOAD CONTROL
ON
0 = OFF, 1 = ON
TEMPERATURE OFFSET
0.0ºC
-1.5 ºC to 1.5ºC
RESET
–
Factory, schedule, WiFi and HomeKit reset
FAILSAFE
OFF
0 = OFF, 1 = ON
Wiring Diagrams
Basic 230V boiler
Combi boiler
OpenTherm boilerFor other wiring diagrams visit:
Two-port zone valve or S-plan
Customer Support
Need help? For assistance please visit: getconnected.honeywellhome.comResideo, 200 Berkshire Place, Winnersh Triangle, Berkshire RG41 5RPhone: 0300 130 1299
ApprovalsHereby, Pittway Sarl declares that the radio equipment type T6 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://hwllhome.co/DoC
Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHzErP: Class V (+3%), (EU) 811/2013
WEEE Directive 2012/19/ECWaste Electrical and Electronic Equipment directive At the end of the product life dispose of the packaging and product in acorresponding recycling centre. Do not dispose of the unit with theusual domestic refuse. Do not burn the product.