Honeywell Home T6R Smart Thermostat Wall Mount User Guide

T6R Smart ThermostatWall Mount

Compatible with 24-230V on/off and OpenTherm® appliances such as gas boilers, combi-boilers and heat pump. Also compatible with Sundial Y- and S-plan stored hot water systems with zone valves.

Need help? For assistance please visit: getconnected.honeywellhome.comResideo, 200 Berkshire Place, Winnersh Triangle, Berkshire RG41 5RPhone: 0300 130 1299ApprovalsHereby, Pittway Sarl declares that the radio equipment type T6H700RW is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is  available at the following internet address: https://hwllhome.co/DoCRF (868MHz): Receiver Category 2, Max RF Power 25mW, 868–868.6MHz (868.3MHz)Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHzERP: Class V (+3%), (EU) 811/2013

Must be installed by a competent person!Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.

Turn OFF the power and remove the old thermostat

To ensure your safety, always make sure mains power is switched OFF before accessing wiring.In case of removing the old thermostat be aware that the existing wiring will no longer be used.

The T6R thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 – 1.5 meters from the floor.

WEEE Directive 2012/19/ECWaste Electrical and Electronic Equipment directiveAt the end of the product, life disposes of the packaging and product in a corresponding recycling center. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.

Prepare Receiver Box for installation

Before installation of the Receiver Box.Find a suitable location near to the boiler. Leave at least 30cm distance from any metal objects including wall boxes and boiler housing.Loosen the front screw to remove the cover or tighten it when the cover is back in place.Needed during installation:

  • Cable with 2 wires from the boiler to Receiver Box.
  • The Receiver Box requires 230V power.

Install the Receiver Box

Please refer to the wiring diagrams over the page

A) Wall box or Rear WiringHinge open the terminal block flap to access the cables and wall box screw holes.

B) Surface wiringUse the cable clamps to secure the surface wiring.

C) Replace the coverLocate the hinges at the top of the cover and wall plate, close the cover and secure with the screw.

Install the T6 thermostat

The wall-mounted power supply requires 230V power. The minimum wall box depth is 40mm.

A) Connect the 230V power wires to the power supply.

B) Using a screwdriver open wallplate terminal cover to connect wiresC) Connect thermostat wires to the terminals: Red to + and Black to – and close cover.

D) Attach the thermostat to the wallplate when finished.

Complete installation

Turn ON mains power to the Heating Appliance and Receiver Box.No binding is needed, Receiver Box and Thermostat are pre-bound.

To rebind the units, reset the Receiver box, then press the button for 3 seconds. The LED on the receiver box will blink yellow to indicate the box is in binding mode. On the thermostat press for 5 seconds to enter the advanced menu. Navigate to Binding, clear the current binding then bind the device again.

Set Up and configuration

Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds. In the advanced menu the following settings can be adjusted:

Menu Item Default Options
LANGUAGE English 0 = English, 1 = Français, 2 = Español3 = Deutsch, 4 = Nederlands, 5 = Italiano
SYSTEM TYPE Heat only Heating only or Heating + Hot Water
OPENTHERM OpenTherm boiler data when available
CYCLE RATE 6 3, 6, 9 or 12
MINIMUM ON TIME 1 minute 1, 2, 3, 4 or 5 minutes
HEAT RANGE Min = 5.0ºCMax = 35.0ºC Min: 5ºC to 21ºC, Max: 21ºC to 35ºC
SCHEDULE OPTIONS Daily 1 = Daily schedule, 2 = 5+2 days schedule
OPTIMISE Opt. start OFF}Opt. stop OFF Opt. start: 0 = off, 1 = on, 2 = Delayed startOpt. stop: 0 = off, 1 = on
CLOCK Format: 24h

Time: –:-Date:

01/09/16

Clock format: 1 = 12h, 2 = 24h

Setup time and date

LOW LOAD CONTROL ON 0 = off, 1 = on
TEMPERATURE OFFSET 0.0ºC -1.5 ºC to 1.5ºC
BINDING Bind, check RF, and clear bind.
RESET Factory, schedule, WiFi, and HomeKit reset
FAILSAFE OFF 0 = off, 1 = on