Honeywell Home TH4110U2005 T4 Pro Programmable Thermostat User Guide

T4 Pro Programmable Thermostat TH4110U2005, TH4210U2002 User Guide

Package Includes:

  • T4 Pro Thermostat
  •  UWP™ Mounting System
  • Decorative Cover Plate
  • Screws and Anchors
  • 2 AA Batteries
  •  Thermostat Literature

Read before installing Thermostat controls

The screen will wake up by pressing any of the five buttons. If powered by the C wire, the screen stays lit for 45 seconds after you complete changes. If powered by battery only, the screen stays lit for 8 seconds. Depending on how your thermostat was installed, the screen light may always be on.

Customer assistanceFor assistance with this product, please visit Honeywellhome.com/support

System operation settings

  1. Press the Mode button to cycle to the next available System mode.
  2. Cycle through the modes until the required System mode is displayed and leave it to activate.NOTE: Available System modes vary by model and system settings.System modes:‒ Auto‒ Heat‒ Cool‒ Off‒ Em. Heat (TH4210U only)

Fan operation settings

  1. Press the Fan button to cycle to the next available Fan mode.
  2. Cycle through the modes until the required Fan mode is displayed and leave it to activate.NOTE: Available Fan modes vary with system settings.Fan modes:‒ Auto: Fan runs only when the heating or cooling system is on.‒ On Fan is always on.

Set the time and date

Time

  1. Press Menu, and then press + to go to TIME. Press Select.
  2. Press + or – to choose between 12 or 24-hour press Select.
  3. Use + or adjust the hour. Press Select.
  4. Use+ or – adjust the minutes. Press Select to exit the Time menu.

Date

  1. If previously setting time, continue to Step2. If at the Home screen, press Menu on your thermostat.
  2. Press + or – to go to DATE. Press Select.
  3. Use + or – adjust the year. Press Select.
  4. Use the + or – to adjust the month. Press Select.
  5. Use the + or – to adjust the Date. Press Select to save and exit the Date menu.

Program Schedule

You can program four time periods each day, with different settings for weekdays and weekends. We recommend the pre-sets (shown in the table below), since they can reduce your heating/cooling expenses.

Wake – Set to the time you wake up and the temperature you want during the morning, until you leave for the day.Away – Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level).Home – Set to the time you return home and the temperature you want during the evening, until bedtime.Sleep – Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).

NOTE: To temporarily or permanently override any of the above program schedules, see page 4.

To adjust program schedules

  1. Press Menu on your thermostat.
  2. PROG is displayed. Press Select. Then ON is displayed. (If you do not want to use a schedule, press + or – to display OFF. Press Select.) Press Select.
  3. Press + or – to select day or set of days to edit. Press Select.
  4. Press + or – to select a schedule period to edit (Wake, Away, Home, and Sleep). Press Select.
  5. ON is displayed. Press Select to keep the schedule period on. Or press + and then Selectto turn off the schedule period.
  6. Time starts blinking. Press or adjust the schedule period start time. Press Select.
  7. The temperature starts blinking. Press + or – to adjust the “Heat” setpoint temperature. Press Select. Press or to adjust the “Cool” temperature setpoint. Press Select.
  8. Repeat steps 4 through 7 for the remaining schedule periods.
  9. Press Home when you’re finished to save and return to the home screen.
  10. Schedule can be adjusted and turned ON or OFF by returning to Menu and following the steps provided above.

Program schedule override (temporary)

  1. Press + or – to adjust the temperature.
  2. Once at the desired setpoint temperature, no further action is needed. The new setpoint temperature will be held until the next scheduled time period begins. For more information on schedule time periods, see “Program Schedule” on page 3.
  3. To cancel the Temporary Hold, Press + or – and then press Cancel.

Program schedule override (permanent)

  1. Press + or – to adjust the temperature.
  2. TEMPORARY HOLD is displayed and the setpoint temperature flashes. While it’s flashing, press the Hold (Mode) button to change to Permanent Hold.
  3. To cancel the Permanent Hold, press + or – and then press Cancel.

Setting degrees Fahrenheit (F) or Celcius (C)

  1. Press Menu.
  2. Press + or – to go to F/C. Press Select.
  3. Press + or – for F or C. Then press Select.
  4. Press Select to save and exit the F/C menu.

Adjusting keypad lockout

  1. Press Menu on the thermostat.
  2. Press +or – to go to LOCK. Press Select.
  3. Press + or – to go to OFF, PART, or ON, and then press Select.OFF: Unlocked, and full access allowed.PART: Partial lockout, allowing only the temperature to be changed.ON: No access allowed.
  4. To unlock the keypad, press the CENTER button and then enter the password“1234”. To enter the password, press + or – change the first digit of the number. Then press Select. Repeat this process to enter the second through fourth digits of the number. Once all four numbers have been entered, press Select again.
  5. This will unlock the keypad.
  6. If the code is incorrect, the screen will flash the lines “–“.
  7. Press Back to go back a step to enter the correct number and press Select.NOTE: On some models, the keypad lockout setting is only available in the installer menu and not available in the user menu.

Adjusting idle backlight display brightness

  1. Press Menu on the thermostat.
  2. Press + or – go to LITE. Press Select.
  3. The current brightness setting is displayed (1-5).
  4. Press + or – adjust backlight brightness.
  5. Press Select to save and exit the LITE menu.NOTE: Backlight is only displayed if the C (common) wire is connected.

Adaptive Intelligent Recovery

Over time, the T4 Pro Thermostat “learns” how long it takes your system to reach the temperature you want. It turns on the heating or cooling system earlier to make sure you’re comfortable at the time you expect.

Built-in compressor protection

Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait for a few minutes before restarting.

During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on.

Battery replacement

When the low battery warning appears, press gently to loosen the thermostat and then carefully pull it from the wall mount.

Batteries are optional (to provide backup power) if your thermostat was wired to run on AC power when installed. If your thermostat was not wired to run on AC power, then batteries are required.Install fresh batteries immediately when the low battery icon appears. The icon appears about two months before the batteries are depleted.Even if the low battery icon does not appear, you should replace batteries once a year, or before leaving home for more than a month.If batteries are inserted within two minutes, the time and day will not have to be reset. All other settings are permanently stored in memory and do not require battery power.NOTE: When replacing batteries, alkaline batteries are recommended.

Alerts

If there is an alert or reminder, the alert icon appears on the Home screen.

Low Battery Warning

  1. The batteries need to be replaced when BATT, the alert icon , and the battery icon are displayed on the Home screen.
  2. When the battery power is very low, the thermostat’s backlight is disabled to save battery power.
  3. When battery power is critically low, only BATT, the alert icon , and the battery icon are displayed.

Air Filter Reminder

  1. The alert icon appears on the Home screen.
  2. Press Menu, and then press + until display shows ALRT.
  3. Press Select to display which alert(s) are present.
  4. The message REPL (REPLACE AIR FILTER) appears.
  5. The reminder can be snoozed or cleared.Resideo recommends changing the air filter before clearing the reminder.
  6. To snooze, press Select. The word SNZE (SNOOZE) appears.
  7. Press Select again to snooze the reminder for days.
  8. To clear, press Select, and then press + to go to CLER (Clear).
  9. Press Select to clear the air filter reminder.

Snoozing and Clearing Alerts or Reminders*

  1. Press Menu, and then press + until display shows ALRT.
  2. Press Select to display which alert(s) are present.
  3. The word SNZE (SNOOZE) appears.
  4. Press Select again to snooze the reminder for 7 days.
  5. To clear the alert, press + Select and then press to go to CLER (Clear).
  6. Press Select to clear the reminder.* Some alerts cannot be snoozed or cleared. Please call your local heating and cooling professional if this occurs. The heating and cooling system may require service.

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

Display is blank • Check circuit breaker and reset if necessary.• Make sure power switch for heating & cooling system is on.• Make sure furnace door is closed securely.• Make sure fresh AA alkaline batteries are correctly installed (see page 6).
Heating or cooling system does not respond • Press Mode button to set system Heat (see page 2).Make sure the desired temperature is set higher than the inside temperature.• Press Mode button to set system Cool (see page 2).Make sure the desired temperature is set lower than the inside temperature.• Check the circuit breaker and reset if necessary.• Make sure the power switch for the heating & cooling system is on.• Make sure furnace door is closed securely.• Wait 5 minutes for the system to respond.
Temperature settings do not change • If the display says “unlock”; see page 5. If not, verify you are in the correct mode (heat, cool, em heat, or auto); see page 2.• If you are in the correct mode, but you cannot set the heat from 40 °F to 90 °F (4.5 °C to 32 °C), or set the cool from 50 °F to 99 °F (10 °C to 37 °C), you may have range-stops restricting your setting. Check with the installer to see if they set range stops.
“Cool On” or “Heat On” is flashing • Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor (see page 5).

Electrical Ratings

Terminal Voltage (50 Hz/60 Hz)  Running Current
W Heating 20 Vac – 30 Vac 0.02 A – 1.0 A
W2 (Aux) Heating (TH4210U only) 20 Vac – 30 Vac 0.02 A – 1.0 A
E Emergency Heat (TH4210U only) 20 Vac – 30 Vac 0.02 A – 0.5 A
Y Compressor Stage 1 20 Vac – 30 Vac 0.02 A – 1.0 A
G Fan 20 Vac – 30 Vac 0.02 A – 0.5 A
O/B Changeover 20 Vac – 30 Vac 0.02 A – 0.5 A
L/A Input 20 Vac – 30 Vac 0.02 A – 0.5 A

FAQs

How do I set the clock?

Press and hold the Set button for 3 seconds to enter the Clock Set mode. Use the Up and Down buttons to set the hours and minutes. Press the Set button to confirm and exit.

How do I set the time of day?

Press and hold the Set button for 3 seconds to enter the Time of Day mode. Use the Up and Down buttons to set the time of day, AM or PM, and date. Press the Set button to confirm and exit.

How do I change System settings?

Press and hold the Mode button for 3 seconds to enter System Setup mode. Use the Up and Down buttons to select a System setting, then press the Mode button to select it. Use the Up and Down buttons to change settings, then press the Mode button to save them. Press any other button to exit System Setup mode.

How do I change Fan settings?

Press and hold the Fan button for 3 seconds to enter Fan Setup mode. Use the Up and Down buttons to select a Fan setting, then press the Fan button to select it. Use the Up and Down buttons to change settings, then press the Fan button to save them. Press any other button to exit Fan Setup mode.

is this a 2 wire or 3 wire

Depending on how old the wiring in your house is, our house was built in 1982.I had 2 wires, a red and a white, on the thermostat, these are labelled R and W. It is easy to install and works great.

Can you connect this thermostat to a smart phone and control it that way?

What you are looking for is a “Wi-Fi” thermostat.. This is not one of them.

How to unlock the Thermostat ?

The password is 1234. Press the center button under unlock. The number 5 shows on the display. Press the minus button until it reads the number 1 and press select. A small number 1 will appear above and a large number 5 will be displayed again. Do the same thing again to enter the number 2, then 3, then 4. Once you have 1234 displayed above press select once more and the thermostat will return to the home screen and will be unlocked.

How many degrees of ac temp swing/differential can be adjusted

The auto mode will keep the house the same temp year round without touching the controls by adjusting between heat and a/c based on the desired need that day. I hope this answers the question.

Does it make a clicking sound when it kicks in?

Patrick, I had no issues with it. No clicking sound. I recently had a new HVAC unit installed and had to replace it because it was not compatible. Hope this helps.

Can model (T4) display the temperature outside when connected to WiFi?

No, it is not Wi-Fi connected.

If i use a c wire and do not use a battery for backup, if the power goes out do the settings get erased?

Yes

Is this for 1H/1C systems with electric heat or gas heat only? Electric heat requires air handler to start same time as heat strips.

Gas only

Can i use this if i have heat only and no a/c?

Yes. And it can be programmed to always be set for heat only mode, but you should still call Honeywell support and they will confirm.

Is the 6.2” across or up and down?

Mine is more like 4” across. It’s not 6.2” anywhere but I am also not using the ‘decorative’ backing that can be used for extra coverage.

Does this thermostat have a circulate function in the fan controls?

This thermostat has a circulate setting on the fan choices.

Video

5-year limited warrantyFor warranty information go to Honeywellhome.com/support

CAUTION: ELECTRICAL HAZARDCan cause electrical shock or equipment damage. Disconnect power before beginning installation.

CAUTION: EQUIPMENT DAMAGE HAZARDCompressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

CAUTION: MERCURY NOTICEIf this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

CAUTION: ELECTRONIC WASTE NOTICEThe product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers.The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health.

FCC statement at:https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx

www.resideo.com

Resideo Technologies Inc.1985 Douglas Drive North, Golden Valley, MN 55422https://www.honeywellhome.com/support33-00188EFS—09 M.S. Rev. 08-20 | Printed in the United States

© 2020 Resideo Technologies, Inc. All rights reserved.  The Honeywell Home trademark is used under licensefrom Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

References

[xyz-ips snippet=”download-snippet”]