Honeywell 50076346 Basic Board Mount Pressure Sensors Installation Guide

50076346 Basic Board Mount Pressure Sensors

INSTALLATION INSTRUCTIONS FOR THEBASIC BOARD MOUNT PRESSURE SENSORS

50076346Issue H

TBP Series: Compensated/Unamplified 60 mbar to 10 bar | 6 kPa to 1 MPa |1 psi to 150 psi, Millivolt Analog Output

NBP Series: Uncompensated/Unamplified 60 mbar to 10 bar | 1 psi to 150 psi, Millivolt Analog Output

GENERAL INFORMATIONHoneywell’s Basic Board Mount Pressure Sensors, TBP Series and NBP Series, are designed for food grade and non-food grade potential medical and industrial applications. These unamplified, piezoresistive silicon pressure sensors provide a ratiometric output and are either temperature compensated (TBP Series) or uncompensated (NBP Series).CAUTIONMISUSE OF GEL COATING OPTION· No gel coating in media path: The input port is limited to non-corrosive, non-ionic media such as dry air and gases and should not be exposed to condensation. The gases are limited to media which are compatible with the following wetted materials of construction: high temperature polyamide, silicone, alumina ceramic, silicon, gold, and glass.· Silicone gel coating in media path: The gel coated sensors use the same materials in the wetted media path but are protected from condensation by a silicone-based gel coating. The gel coating option allows use in applications where condensation can occur.Failure to comply with these instructions may result in product damage.

SOLDERING See soldering times and temperatures in Table 1.

CAUTIONIMPROPER CLEANING· Ensure cleaning fluids, such as appropriate alcohols or fluorinated solvents, are used based on the type of contaminants to be removed.· Do not immerse the sensor.Failure to comply with these instructions may result in product damage.

TABLE 2. ABSOLUTE MAXIMUM RATINGS1

CHARACTERISTIC Supply voltage (Vsupply)2 Storage temperature

MIN.

MAX.

-12.0

12.0

-40 [-40] 125 [257]

UNIT Vdc°C [°F]

Soldering time and temperature:lead solder temperature (DIP)peak reflow temperature (SMT, Leadless SMT)

4 s max. at 250°C [482°F] 15 s max. at 250°C [482°F]

1Absolute maximum ratings are the extreme limits the device will withstand without damage. 2Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.

TABLE 1. OPERATING SPECIFICATIONS

CHARACTERISTIC

MIN.

TYP.

MAX.

UNIT

TBP SERIES

Supply voltage (Vsupply)1, 2 Supply current (at 5.0 Vdc supply) Operating temperature range3 Compensated temperature range4 Output resistance

1.5 — -40 [-40] 0 [32] —

5.0

12.0

Vdc

0.6

1

mA

125 [257]

°C [°F]

85 [185]

°C [°F]

2.5

kOhm

NBP SERIES

Supply voltage (Vsupply)1, 2 Supply current (at 5.0 Vdc supply)

1.8

5.0

12.0

Vdc

1.5

2.5

mA

Specified temperature range5

-40 [-40]

125 [257]

°C [°F]

Accuracy6

±0.25

%FSS BFSL7

Input resistance

2.4

3.0

5.5

kOhm

Thermal effect on resistance (TER)8

1200

3200

ppm/°C

1Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage. 2Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 3Operating temperature range: The temperature range over which the sensor produces an output proportional to pressure. 4Compensated temperature range: The temperature range over which the sensor produces an output proportional to pressure within the specified performance limits. 5Specified temperature range: The temperature range over which the sensor will produce an output proportional to pressure within the specified performance limits. 6Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C [77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 7Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum and minimum limits of the pressure range. (See Figure 2 for pressure ranges.) 8TER (Thermal Effect on Resistance): The deviation in input resistance due to change in temperature over the specified temperature range, relative to input resistance measured at 25°C [77°F].

Honeywell

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

TABLE 2. PRESSURE REFERENCE TYPES

PRESSURE TYPE Absolute Differential Gage

DESCRIPTIONOutput is proportional to the difference between applied pressure and a built-in reference to vacuum. Reference pressure is absolute zero pressure (full vacuum).Output is proportional to the difference between the pressures applied to each port (Port 1 – Port 2).Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure. Reference pressure is atmospheric pressure.

TABLE 3. ENVIRONMENTAL SPECIFICATIONS

CHARACTERISTICHumidity: all external surfaces internal surfaces of silicone gel coating option internal surfaces of no gel coating optionVibration

PARAMETER0 %RH to 95 %RH, non-condensing 0 %RH to 100 %RH, condensing 0 %RH to 95 %RH, non-condensing MIL-STD-202G, Method 204D, Condition B (15 g, 10 Hz to 2 kHz)

Shock

MIL-STD-202G, Method 213B, Condition C (100 g, 6 ms duration)

Life1

1 million pressure cycles min.

ESD

MIL-STD-883 Method 3015.7

Solder reflow

J-STD-020E, MSL 1, unlimited storage life

Certification (silicone gel coating option: Port 1 only) NSF- 169, BPA Free, LFGB 1Life may vary depending on specific application in which the sensor is utilized.

TABLE 4. WETTED MATERIALS1

COMPONENT

PRESSURE PORT 1 (P1)

NO GEL COATING IN MEDIA PATH

SILICONE GEL COATING IN MEDIA PATH (FOOD GRADE)

Ports and covers

high temperature polyamide

Substrate

alumina ceramic

Adhesives

epoxy, silicone

epoxy, silicone gel

Electronic components silicon, gold, glass, solder, aluminum 1Contact Honeywell Customer Service for detailed material information.

304SST

PPRESSURE PORT 2 (P2)alumina ceramic epoxy, silicone silicon

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 2

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

Pressure Range Order Code (see Figure 1) Pmin. Pmax. Unit Port 1 Port 2 Port 1 Port 2Common Mode Pressure3 Pressure Accuracy (%FSS)4Offset (mV/V)5 Long-Term Stability 1000 hrat 25°C (%FSS) Thermal Hysteresis No Gel Option (%FSS)9 Thermal Hysteresis Silicone Gel Option (%FSS)9

TABLE 5. TBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 60 MBAR TO 10 BAR

Pressure Range

OverPressure1

Burst Pressure2

Full Scale Span (mV/V)6

Thermal Ef- Thermal Effect

fect on Offset on Span

(%FSS)7

(%FSS)8

10ºC 0ºC 10ºC 0ºC

Min. Nom. Max. to

to

to

to

50ºC 85ºC 50ºC 85ºC

GAGE

060MG 0 60 mbar 872 — 1370 — — ±0.20 ±0.075 1.23 1.30 1.40 ±1.15 ±2.35 ±1.00 ±2.00 ±0.45 ±0.40 ±0.60

100MG 0 100 mbar 872 — 1370 — — ±0.20 ±0.075 2.06 2.20 2.33 ±0.70 ±1.40 ±1.00 ±2.00 ±0.30 ±0.25 ±0.35

160MG 0 160 mbar 2000 — 4000 — — ±0.15 ±0.12 2.18 2.30 2.46 ±1.65 ±3.30 ±0.75 ±2.00 ±0.55 ±0.35 ±0.55

250MG 0 250 mbar 2000 — 4000 — — ±0.15 ±0.12 3.41 3.65 3.85 ±1.05 ±2.10 ±0.75 ±2.00 ±0.35 ±0.20 ±0.35

400MG 0 400 mbar 2000 — 4000 — — ±0.15 ±0.12 5.45 5.80 6.15 ±0.65 ±1.30 ±0.75 ±2.00 ±0.20 ±0.15 ±0.20

600MG 0 600 mbar 4000 — 8000 — — ±0.15 ±0.075 2.94 3.05 3.18 ±0.85 ±1.65 ±0.50 ±1.25 ±0.40 ±0.15 ±0.35

001BG 0 1 bar 4 — 8 — — ±0.15 ±0.075 4.90 5.10 5.30 ±0.50 ±1.00 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20

1.6BG

0 1.6 bar 4 — 8 —

— ±0.15 ±0.075 7.84 8.15 8.48 ±0.30 ±0.65 ±0.50 ±1.25 ±0.15 ±0.10 ±0.15

2.5BG

0 2.5 bar 8 — 17 —

— ±0.15 ±0.075 6.10 6.35 6.59 ±0.40 ±0.80 ±0.50 ±1.50 ±0.20 ±0.10 ±0.15

004BG 0 4 bar 10 — 17 — — ±0.15 ±0.075 5.57 5.80 6.04 ±0.50 ±1.00 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20

006BG 0 6 bar 17 — 21 — — ±0.15 ±0.075 5.08 5.30 5.54 ±0.65 ±1.00 ±0.50 ±1.00 ±0.25 ±0.15 ±0.25

010BG 0 10 bar 17 — 21 — — ±0.15 ±0.075 8.47 8.85 9.22 ±0.40 ±0.60 ±0.50 ±1.00 ±0.15 ±0.10 ±0.15

DIFFERENTIAL

060MD -60 60 mbar 872 872 1370 1370 10000 ±0.20 ±0.075 2.46 2.60 2.80 ±0.60 ±1.20 ±1.00 ±2.00 ±0.25 ±0.20 ±0.30

100MD -100 100 mbar 872 872 1370 1370 10000 ±0.20 ±0.075 4.12 4.40 4.66 ±0.35 ±0.70 ±1.00 ±2.00 ±0.15 ±0.15 ±0.20

160MD -160 160 mbar 2000 2000 4000 4000 10000 ±0.15 ±0.12 4.36 4.60 4.92 ±0.85 ±1.65 ±0.75 ±2.00 ±0.30 ±0.20 ±0.30

250MD -250 250 mbar 2000 2000 4000 4000 10000 ±0.15 ±0.12 6.82 7.30 7.70 ±0.55 ±1.05 ±0.75 ±2.00 ±0.20 ±0.10 ±0.20

400MD -400 400 mbar 2000 2000 4000 4000 10000 ±0.15 ±0.12 10.90 11.60 12.30 ±0.35 ±0.65 ±0.75 ±2.00 ±0.10 ±0.10 ±0.10

600MD -600 600 mbar 4000 4000 8000 8000 10000 ±0.15 ±0.075 5.88 6.10 6.36 ±0.45 ±0.85 ±0.50 ±1.25 ±0.20 ±0.10 ±0.20

001BD -1 1 bar 4 4 8 8 10 ±0.15 ±0.075 9.80 10.20 10.60 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10

1.6BD -1.6 1.6 bar 4 4 8 8 10 ±0.15 ±0.075 15.68 16.30 16.96 ±0.15 ±0.35 ±0.50 ±1.25 ±0.10 ±0.10 ±0.10

2.5BD -2.5 2.5 bar 8 8 17 17 10 ±0.15 ±0.075 12.20 12.70 13.18 ±0.20 ±0.40 ±0.50 ±1.50 ±0.10 ±0.10 ±0.10

004BD -4 4 bar 10 10 17 17 15 ±0.15 ±0.075 11.14 11.60 12.08 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.101Overpressure: The maximum pressure which may safely be applied to the product for it to remain within specifications once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all available pressure ports at any temperature within the operating temperature range.2Burst pressure: The maximum pressure that may be applied to the specified port (P1 or P2) of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure.3Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance.4Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.5Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”.6Full Scale Span: The algebraic difference between the output signal measured at the maximum and minimum limits of the pressure range (see Figure 1 for pressure ranges).7Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at 25ºC.8Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range, relative to full scale span measured at 25ºC.9Thermal hysteresis: The maximum difference between output readings when the same temperature is reached consecutively, under the same operating conditions, with temperature approaching from opposite directions within the operating temperature range. Validated over the full operating temperature and pressure ranges using a ~5ºC/ minute ramp and 30 minute dwell. Application performance may be affected by thermal mass of end user system.

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 3

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

Pressure Range Order Code (see Figure 1) Pmin. Pmax. Unit Port 1 Port 2 Port 1 Port 2Common Mode Pressure3 Pressure Accuracy (%FSS)4Offset (mV/V)5 Long-Term Stability 1000 hrat 25°C (%FSS) Thermal Hysteresis No Gel Option (%FSS)9 Thermal Hysteresis Silicone Gel Option (%FSS)9

TABLE 6. TBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 6 KPA TO 1 MPA

Pressure Range

OverPressure1

Burst Pressure2

Full Scale Span (mV/V)6

Thermal Effect Thermal Effect

on Offset

on Span

(%FSS)7

(%FSS)8

10ºC 0ºC 10ºC 0ºC

Min. Nom. Max. to

to

to

to

50ºC 85ºC 50ºC 85ºC

GAGE006KG 0 6 kPa 87 — 137 — — ±0.20 ±0.075 1.23 1.30 1.40 ±1.15 ±2.35 ±1.00 ±2.00 ±0.45 ±0.40 ±0.60010KG 0 10 kPa 87 — 137 — — ±0.20 ±0.075 2.06 2.20 2.33 ±0.70 ±1.40 ±1.00 ±2.00 ±0.30 ±0.25 ±0.35016KG 0 16 kPa 200 — 400 — — ±0.15 ±0.12 2.18 2.30 2.46 ±1.65 ±3.30 ±0.75 ±2.00 ±0.55 ±0.35 ±0.55025KG 0 25 kPa 200 — 400 — — ±0.15 ±0.12 3.41 3.65 3.85 ±1.05 ±2.10 ±0.75 ±2.00 ±0.35 ±0.20 ±0.35040KG 0 40 kPa 200 — 400 — — ±0.15 ±0.12 5.45 5.80 6.15 ±0.65 ±1.30 ±0.75 ±2.00 ±0.20 ±0.15 ±0.20060KG 0 60 kPa 400 — 800 — — ±0.15 ±0.075 2.94 3.05 3.18 ±0.85 ±1.65 ±0.50 ±1.25 ±0.40 ±0.15 ±0.35100KG 0 100 kPa 400 — 800 — — ±0.15 ±0.075 4.90 5.10 5.30 ±0.50 ±1.00 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20160KG 0 160 kPa 400 — 800 — — ±0.15 ±0.075 7.84 8.15 8.48 ±0.30 ±0.65 ±0.50 ±1.25 ±0.15 ±0.10 ±0.15250KG 0 250 kPa 800 — 1700 — — ±0.15 ±0.075 6.10 6.35 6.59 ±0.40 ±0.80 ±0.50 ±1.50 ±0.20 ±0.10 ±0.15400KG 0 400 kPa 1000 — 1700 — — ±0.15 ±0.075 5.57 5.80 6.04 ±0.50 ±1.00 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20600KG 0 600 kPa 1700 — 2100 — — ±0.15 ±0.075 5.08 5.30 5.54 ±0.65 ±1.00 ±0.50 ±1.00 ±0.25 ±0.15 ±0.25001GG 0 1 MPa 1.70 — 2.10 — — ±0.15 ±0.075 8.47 8.85 9.22 ±0.40 ±0.60 ±0.50 ±1.00 ±0.15 ±0.10 ±0.15DIFFERENTIAL006KD -6 6 kPa 87 87 137 137 1000 ±0.20 ±0.075 2.46 2.60 2.80 ±0.60 ±1.20 ±1.00 ±2.00 ±0.25 ±0.20 ±0.30010KD -10 10 kPa 87 87 137 137 1000 ±0.20 ±0.075 4.12 4.40 4.66 ±0.35 ±0.70 ±1.00 ±2.00 ±0.15 ±0.15 ±0.20016KD -16 16 kPa 200 200 400 400 1000 ±0.15 ±0.12 4.36 4.60 4.92 ±0.85 ±1.65 ±0.75 ±2.00 ±0.30 ±0.20 ±0.30025KD -25 25 kPa 200 200 400 400 1000 ±0.15 ±0.12 6.82 7.30 7.70 ±0.55 ±1.05 ±0.75 ±2.00 ±0.20 ±0.10 ±0.20040KD -40 40 kPa 200 200 400 400 1000 ±0.15 ±0.12 10.90 11.60 12.30 ±0.35 ±0.65 ±0.75 ±2.00 ±0.10 ±0.10 ±0.10060KD -60 60 kPa 400 400 800 800 1000 ±0.15 ±0.075 5.88 6.10 6.36 ±0.45 ±0.85 ±0.50 ±1.25 ±0.20 ±0.10 ±0.20100KD -100 100 kPa 400 400 800 800 1000 ±0.15 ±0.075 9.80 10.20 10.60 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10160KD -160 160 kPa 400 400 800 800 1000 ±0.15 ±0.075 15.68 16.30 16.96 ±0.15 ±0.35 ±0.50 ±1.25 ±0.10 ±0.10 ±0.10250KD -250 250 kPa 800 800 1700 1700 1000 ±0.15 ±0.075 12.20 12.70 13.18 ±0.20 ±0.40 ±0.50 ±1.50 ±0.10 ±0.10 ±0.10400KD -400 400 kPa 1000 1000 1700 1700 1500 ±0.15 ±0.075 11.14 11.60 12.08 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10 1Overpressure: The maximum pressure which may safely be applied to the product for it to remain within specifications once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all available pressure ports at any temperature within the operating temperature range. 2Burst pressure: The maximum pressure that may be applied to the specified port (P1 or P2) of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure. 3Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance. 4Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 5Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”. 6Full Scale Span: The algebraic difference between the output signal measured at the maximum and minimum limits of the pressure range (see Figure 1 for pressure ranges). 7Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at 25ºC. 8Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range, relative to full scale span measured at 25ºC. 9Thermal hysteresis: The maximum difference between output readings when the same temperature is reached consecutively, under the same operating conditions, with temperature approaching from opposite directions within the operating temperature range. Validated over the full operating temperature and pressure ranges using a ~5ºC/ minute ramp and 30 minute dwell. Application performance may be affected by thermal mass of end user system.TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 4

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

Pressure Range Order Code (see Figure 1) Pmin. Pmax. Unit Port 1 Port 2 Port 1 Port 2Common Mode Pressure3 Pressure Accuracy (%FSS)4Offset (mV/V)5 Long-Term Stability 1000 hrat 25°C (%FSS) Thermal Hysteresis No Gel Option (%FSS)9 Thermal Hysteresis Silicone Gel Option (%FSS)9

TABLE 7. TBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 1 PSI TO 150 PSI

Pressure Range

OverPressure1

Burst Pressure2

Full Scale Span (mV/V)6

Thermal Ef- Thermal Effect

fect on Offset on Span

(%FSS)7

(%FSS)8

10ºC 0ºC 10ºC 0ºC Min. Nom. Max. to to to to50ºC 85ºC 50ºC 85ºC

GAGE

001PG 0 1 psi 12.7 — 20 — — ±0.20 ±0.075 1.42 1.50 1.61 ±1.00 ±2.05 ±1.00 ±2.00 ±0.40 ±0.35 ±0.50

005PG 0 5 psi 30 — 60 — — ±0.15 ±0.12 4.70 5.00 5.30 ±0.75 ±1.50 ±0.75 ±2.00 ±0.25 ±0.15 ±0.25

015PG 0 15 psi 60 — 115 — — ±0.15 ±0.075 5.06 5.25 5.49 ±0.50 ±0.95 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20

030PG 0 30 psi 115 — 245 — — ±0.15 ±0.075 5.05 5.25 5.45 ±0.50 ±0.95 ±0.50 ±1.50 ±0.25 ±0.10 ±0.20

060PG 100PG 150PG

0 60 psi 145 — 245 — 0 100 psi 245 — 300 — 0 150 psi 245 — 300 —

— ±0.15 ±0.075 5.76 6.00 6.24 ±0.50 ±0.95 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20 — ±0.15 ±0.075 5.83 6.10 6.36 ±0.60 ±0.85 ±0.50 ±1.00 ±0.25 ±0.10 ±0.25 — ±0.15 ±0.075 8.75 9.15 9.54 ±0.40 ±0.60 ±0.50 ±1.00 ±0.15 ±0.10 ±0.15

DIFFERENTIAL

001PD -1 1 psi 12.7 12.7 20 20 150 ±0.20 ±0.075 2.84 3.00 3.22 ±0.50 ±1.05 ±1.00 ±2.00 ±0.20 ±0.20 ±0.25

005PD -5 5 psi 30 30 60 60 150 ±0.15 ±0.12 9.40 10.00 10.60 ±0.40 ±0.75 ±0.75 ±2.00 ±0.15 ±0.10 ±0.15

015PD -15 15 psi 60 60 115 115 150 ±0.15 ±0.075 10.12 10.50 10.98 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10

030PD -30 30 psi 115 115 245 245 150 ±0.15 ±0.075 10.10 10.50 10.90 ±0.25 ±0.50 ±0.50 ±1.50 ±0.15 ±0.10 ±0.10

060PD -60 60 psi 145 145 245 245 250 ±0.15 ±0.075 11.52 12.00 12.48 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.101Overpressure: The maximum pressure which may safely be applied to the product for it to remain within specifications once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all available pressure ports at any temperature within the operating temperature range.2Burst pressure: The maximum pressure that may be applied to the specified port (P1 or P2) of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure.3Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance.4Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.5Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”.6Full Scale Span: The algebraic difference between the output signal measured at the maxumum and minimum limits of the pressure range (see Figure 1 for pressure ranges).7Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at 25ºC.8Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range, relative to full scale span measured at 25ºC.9Thermal hysteresis: The maximum difference between output readings when the same temperature is reached consecutively, under the same operating conditions, with temperature approaching from opposite directions within the operating temperature range. Validated over the full operating temperature and pressure ranges using a ~5ºC/ minute ramp and 30 minute dwell. Application performance may be affected by thermal mass of end user system.

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 5

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

TABLE 8. NBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 60 MBAR TO 10 BAR

Pressure Range

OverPressure1

Burst Pressure2

Offset4 (mV/V)

Sensitivity

Thermal Effect on Offset Thermal Effect on Span

(mV/V/Full Scale Span)

(%FSS/25ºC)5

(%FSS/25ºC)6

Pressure Range (see Figure 2) Pmin. Pmax.Unit Port 1 Port 2 Port 1 Port 2 Common ModePressure3

Min. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

ABSOLUTE

001BA 0

1 bar 2

4

— -7.0 7.0 10.0 15.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5

1.6BA

0 1.6 bar 4

8

— -7.0 7.0 12.0 16.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5

2.5BA

0 2.5 bar 4

8

— -7.0 7.0 18.8 25.0 31.3 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

004BA 0

4 bar 8

— 16 —

— -7.0 7.0 16.8 20.0 23.2 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

006BA 0

6 bar 16 — 20 —

— -7.0 7.0 12.6 15.0 17.4 -1.5 -0.4 1.5 -6.0 -5.0 -3.5

010BA 0

10 bar 16 —

20 —

— -7.0 7.0 21.0 25.0 29.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

GAGE

060MG 0

60 mbar 850 — 1400 —

— -8.5 8.5 3.9 5.7 7.4 -3.5 -1.2 3.5 -6.0 -5.0 -3.5

100MG 0 100 mbar 850 — 1400 —

— -8.5 8.5 6.6 9.4 12.3 -2.1 -0.7 2.1 -6.0 -5.0 -3.5

160MG 0 160 mbar 850 — 1400 —

— -8.5 8.5 10.5 15.1 19.7 -1.3 -0.4 1.3 -6.0 -5.0 -3.5

250MG 0 250 mbar 1800 — 3000 —

— -8.5 8.5 7.3 10.9 14.5 -2.1 -0.7 2.1 -6.0 -5.0 -3.5

400MG 0 400 mbar 1800 — 3000 —

— -8.5 8.5 11.7 17.4 23.2 -1.3 -0.4 1.3 -6.0 -5.0 -3.5

600MG 0 600 mbar 2000 — 4000 —

— -7.0 7.0 6.0 9.0 12.0 -2.5 -1.0 2.5 -6.0 -5.0 -3.5

001BG 0

1 bar 2

4

— -7.0 7.0 10.0 15.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5

1.6BG

0 1.6 bar 4

8

— -7.0 7.0 12.0 16.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5

2.5BG

0 2.5 bar 4

8

— -7.0 7.0 18.8 25.0 31.3 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

004BG 0

4 bar 8

— 16 —

— -7.0 7.0 16.8 20.0 23.2 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

006BG 0

6 bar 16 — 20 —

— -7.0 7.0 12.6 15.0 17.4 -1.5 -0.4 1.5 -6.0 -5.0 -3.5

010BG 0

10 bar 16 —

20 —

— -7.0 7.0 21.0 25.0 29.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

DIFFERENTIAL

060MD -60 60 mbar 850 850 1400 1400 10000 -8.5 8.5 7.8 11.4 14.8 -1.8 -0.6 1.8 -6.0 -5.0 -3.5

100MD -100 100 mbar 850 850 1400 1400 10000 -8.5 8.5 13.2 18.8 24.6 -1.1 -0.4 1.1 -6.0 -5.0 -3.5

160MD -160 160 mbar 850 850 1400 1400 10000 -8.5 8.5 21.0 30.2 39.4 -0.7 -0.2 0.7 -6.0 -5.0 -3.5

250MD -250 250 mbar 1800 1800 3000 3000 10000 -8.5 8.5 14.6 21.8 29.0 -1.1 -0.4 1.1 -6.0 -5.0 -3.5

400MD -400 400 mbar 1800 1800 3000 3000 10000 -8.5 8.5 23.4 34.8 46.4 -0.7 -0.2 0.7 -6.0 -5.0 -3.5

600MD -600 600 mbar 2000 2000 4000 4000 10000 -7.0 7.0 12.0 18.0 24.0 -1.3 -0.5 1.3 -6.0 -5.0 -3.5

001BD -1

1

bar

2

2

4

4 10 -7.0 7.0 20.0 30.0 40.0 -0.8 -0.3 0.8 -6.0 -5.0 -3.5

1.6BD -1.6 1.6 bar 4

4

8

8 10 -7.0 7.0 24.0 32.0 40.0 -0.8 -0.3 0.8 -6.0 -5.0 -3.5

2.5BD -2.5 2.5 bar 4

4

8

8 10 -7.0 7.0 37.6 50.0 62.6 -0.5 -0.2 0.5 -6.0 -5.0 -3.5

004BD -4

4 bar 8

8

16 16 15 -7.0 7.0 33.6 40.0 46.4 -0.5 -0.2 0.5 -6.0 -5.0 -3.5

1Overpressure: The maximum pressure which may safely be applied to the product for it to remain within specifications once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all available pressure ports at any temperature within the operating temperature range.

2Burst pressure: The maximum pressure that may be applied to the specified port (P1 or P2) of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure.3Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance.

4Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”.

5TCO (Thermal Effect on Offset): The deviation in offset due to changes in temperature over the specified temperature range, relative to offset measured at 25ºC.

6TCS (Thermal Effect on Span): The deviation in full scale span due to changes in temperature over the specified temperature range, relative to full scale span measured at 25ºC.

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 6

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

TABLE 9. NBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 1 PSI TO 150 PSI

Pressure Range

OverPressure1

Burst Pressure2

Offset4 (mV/V)

Sensitivity

Thermal Effect on Offset Thermal Effect on Span

(mV/V/Full Scale Span)

(%FSS/25ºC)5

(%FSS/25ºC)6

Pressure Range (see Figure 2) Pmin. Pmax.Unit Port 1 Port 2 Port 1 Port 2 Common ModePressure3

Min. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

ABSOLUTE

015PA 0

15 psi 30

60

— -7.0 7.0 10.3 15.0 20.7 -1.5 -0.6 1.5 -6.0 -5.0 -3.5

030PA 0

30 psi 60

— 120 —

— -7.0 7.0 15.5 21.0 26.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5

060PA 0

60 psi 120 — 240 —

— -7.0 7.0 17.4 21.0 24.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

100PA 0 100 psi 240 — 300 —

— -7.0 7.0 14.5 17.2 20.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5

150PA 0 150 psi 240 — 300 —

— -7.0 7.0 21.7 26.0 30.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

GAGE

001PG 0

1 psi 10 — 20 —

— -8.5 8.5 4.5 6.5 8.5 -3.0 -1.0 3.0 -6.0 -5.0 -3.5

005PG 0

5 psi 30 — 40 —

— -8.5 8.5 10.0 15.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5

015PG 0

15 psi 30

60

— -7.0 7.0 10.3 15.0 20.7 -1.5 -0.6 1.5 -6.0 -5.0 -3.5

030PG 0

30 psi 60

— 120 —

— -7.0 7.0 15.5 21.0 26.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5

060PG 0

60 psi 120 — 240 —

— -7.0 7.0 17.4 21.0 24.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

100PG 0 100 psi 240 — 300 —

— -7.0 7.0 14.5 17.2 20.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5

150PG 0 150 psi 240 — 300 —

— -7.0 7.0 21.7 26.0 30.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5

DIFFERENTIAL

001PD -1

1

psi 10 10 20 20 150 -8.5 8.5 9.0 13.0 17.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5

005PD -5

5

psi 30 30 40 40 150 -8.5 8.5 20.0 30.0 40.0 -0.8 -0.3 0.8 -6.0 -5.0 -3.5

015PD -15 15 psi 30 30 60 60 150 -7.0 7.0 20.6 30.0 41.4 -0.8 -0.3 0.8 -6.0 -5.0 -3.5

030PD -30 30 psi 60 60 120 120 150 -7.0 7.0 31.0 42.0 52.0 -0.5 -0.2 0.5 -6.0 -5.0 -3.5

060PD -60 60 psi 120 120 240 240 250 -7.0 7.0 34.8 42.0 48.0 -0.5 -0.2 0.5 -6.0 -5.0 -3.51Overpressure: The maximum pressure which may safely be applied to the product for it to remain within specifications once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all available pressure ports at any temperature within the operating temperature range. 2Burst pressure: The maximum pressure that may be applied to the specified port (P1 or P2) of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure. 3Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance.4Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”.5TCO (Thermal Effect on Offset): The deviation in offset due to changes in temperature over the specified temperature range, relative to offset measured at 25ºC.6TCS (Thermal Effect on Span): The deviation in full scale span due to changes in temperature over the specified temperature range, relative to full scale span.

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 7

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)

AN: Single axial small barbed port

7,00 [0.276]43

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

No gel coating option: 10,35 [0.407]

Silicone gel coating option: 10,60 [0.417]

1,02

2,54 TYP.

[0.040

[0.100] 3 4

5,50 [0.217]

3,56 [0.140]

ø0,80[0.032]

11,00 [0.433]

ø1,91[0.075]

PIN 1 INDICATOR

12

3,50 [0.138]

ø2,74[0.108]ø2,32[0.091]ø6,40[0.252]

11,70 [0.461

8,64 [0.340]

0,25 TYP. [0.010]

21

2X 2,23 [0.088]

4X 3,81 [0.150]

JJ: Dual radial barbless port

1,50 [0.059]PORT 1PORT 2PIN 1 INDICATOR 2X 1,88[0.074]

4X 0,46 [0.018]

7,00 [0.276]4 3

No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]0,9 [0.04]5,50 [0.217]

11,00 [0.433]

ø6,40[0.252]

12

3,50 [0.138]

PORT 12,23 [0.088]

5,33 [0.210]

1,02 [0.040]

2,54 TYP.[0.100] 34

2X 2,23 [0.088]

ø6,40[0.252]

11,70 [0.461]

ø0,80[0.032]

PORT 2

0,9 [0.04]8,64 [0.340]

0,25 TYP. [0.010]

21

JN: Single radial barbless port

3,81 [0.150]4X 0,46 [0.018] 13,00 MAX. [0.512]7,00 [0.276] 43ø1,88[0.074]

No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]

5,50 [0.217]11,00 [0.433] 0,75 [0.030]

0,9 [0.04]ø6,41[0.252]

PIN 1 INDICATOR

12

13,00 MAX. [0.512]

2,3 [0.09]

3,50 [0.138]

4X 3,81 [0.150]

1,02 [0.040]

2,54 TYP.[0.100] 34

2X 2,23 [0.088]

ø0,80[0.032]11,70 [0.461

8,64 [0.340]

0,25 TYP. [0.010]

21

4X 0,46 [0.018]TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 8

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)

KN: Single axial large barbed port

7,00 [0.276]43

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

No gel coating option: 11,00 [0.433] Silicone gel coating option: 11,25 [0.443]

1,02 [0.040]

2,54 TYP. [0.100] 3 4

2,23 [0.088]

11,00 [0.433]

5,50 [0.217]

3,301 [0.130]ø3,05[0.120]

ø0,80[0.032]11,70 [0.461

PIN 1 INDICATOR

12

3,50

[0.138]

ø4,92[0.194]ø3,81[0.150]ø6,40[0.252]

8,64 [0.340]

0,25 TYP. [0.010]

21

LN: Single axial barbless port

4X 3,81 [0.150]

4X 0,46 [0.018]7,00 [0.276] 43

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

11,00 [0.433]

5,50 [0.217]

ø3,18[0.125]

PIN 1 INDICATOR

12

3,50 [0.138]

ø6,40[0.252]

No gel coating option: 10,35 [0.407]

Silicone gel coating option: 10,60 [0.417]

1,02 [0.040]

2,54 TYP.

2,23

[0.100] 3 4 [0.088]

ø0,80[0.032]

11,70 [0.461

4X 1,27 [0.050]

8,64 [0.340]

0,25 TYP. [0.010]

2

1

4X 0,46

[0.018]

PN: Low-profile port

4X 3,81 [0.150]

11,00 [0.433]

4X 0,46 [0.018]7,00 [0.276] 43

3,70 MAX. [0.146]2,10 MIN. [0.083]

5,50 [0.217]

ø6,50[0.256]

PIN 1 INDICATOR

12 3,50[0.138]

4X 3,81 [0.150]

2,54 TYP.

2X 2,23

[0.100]

[0.088]

34

ø0,80[0.032]11,70 [0.461]

1,02 [0.040]8,64 [0.340]

0,25 TYP. [0.010]

21

4X 0,46 [0.018]TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 9

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)

RN: Single radial barbed port

ø2,32[0.091]ø1,91[0.075]3,56 [0.140]

7,00 [0.276]4 3

No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]

5,50 [0.217]11,00 [0.433]0,75 [0.030]

1,2 [0.05]ø6,40[0.252]

1,02 [0.040]

2,54 TYP. [0.100]

2X 2,23 [0.088]

34

ø0,80[0.032]11,70 [0.461]

PIN 1 INDICATOR

1

ø2,74[0.108]

13,00 MAX. [0.512]

23,50 [0.138]

2,3 [0.09]

4X 3,81 [0.150]

8,64 [0.340]

0,25 TYP. [0.010]

21

RR: Dual radial barbed port

4X 0,46 [0.018]

ø2,321[0.091]PORT 1 1,50 [0.059]

7,00 [0.276] 43

No gel coating option: 2,23 [0.088] Silicon gel coating option: 2,48 [0.098]

5,50 [0.217]11,00 [0.433]

1,2 [0.05]ø6,40[0.252]

PORT 2

PIN 1

1

INDICATOR

2X ø1,91[0.075]13,00 MAX.[0.512]

23,50 [0.138]

PORT 12,23 [0.088]

1,02 [0.040]PORT 2

2,54 TYP.[0.100] 34

ø6,40[0.252]

11,70 [0.461

2X 2,23 [0.088]0,75 [0.029]

1,2 [0.05] 8,64 [0.340]

0,25 TYP. [0.010]

21

2X 5,33 [0.210]2X ø2,74[0.108]VN: Single axial barbless straight port11,00 [0.433]

4X 3,81 [0.150]

4X 0,46 [0.018]

7,00 [0.276]43

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [.090]

5,50 [0.217]

ø2,58[0.101]

PIN 1 INDICATOR

12

3,50

[0.138]

ø6,40[0.252]

No gel coating option: 8,05 [0.317]

Silicone gel coating option: 8,30 [0.327]

1,02

2,54 TYP.

[0.040]

[0.100] 3 4

2X 2,23 [0.088]

ø0,80[0.032]11,70 [0.461

8,64 [0.340]

0,25 TYP. [0.010]

21

4X 3,81 [0.150]4X 0,46 [0.018]TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 10

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)

Recommended DIP Package PCB Pad Layout

2,54 [0.100]

DIP PACKAGE PINOUT

PIN

FUNCTION

1

Vsupply

11,50

[0.45]

2

Vout-

3

GND

4

Vout+

ø0,813[0.032]

FIGURE 2. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].) AN: Single axial small barbed port

7,00 [0.276]43

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60 [0.417]

1,02 [0.040]

2,54 TYP.

2,23

[0.100] 3

4

[0.088]

11,00 [0.433]PIN 1 INDICATOR

5,50 [0.217]12 3,50[0.138]

3,56 [0.140]ø1,91[0.075]ø2,74[0.108]ø2,32[0.091]ø6,40[0.252]

11,70 [0.461]

ø0,80[0.032]

3,03 [0.119]

0,25 TYP. [0.010]

2

1

4X 0,46 [0.018]

4X 1,27 [0.050]

JN: Single radial barbless port

1,88 [0.074]

7,00 [0.276] 4 3

No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]

5,50 [0.217]

0,9 [0.04]

11,00 [0.433] 0,75 [0.030]

ø6,41[0.252]

PIN 1 INDICATOR

123,50 [0.138]

13,00 MAX. [0.512]

2,3 [0.09]

1,02 [0.040]

2,54 TYP.

[0.100]

34

ø0,80[0.032]

2X 2,23 [0.088]

11,70 [0.461]

3,03 [0.119]

0,25 TYP. [0.010]

21

4X 1,27 [0.050]

4X 0,46 [0.018]

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 11

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

FIGURE 2. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.) KN: Single axial large barbed port

7,00 [0.276]43

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

No gel coating option: 11,00 [0.433] Silicone gel coating option: 11,25 [0.443]

1,02

2,54 TYP.

[0.040]

[0.100]

34

11,00 [0.433]

5,50 [0.217]

3,30 [0.130]ø3,05[0.120]

ø0,80[0.032]11,70 [0.461

PIN 1 INDICATOR

123,50 [0.138]

ø4,92[0.194]ø3,81[0.150]ø6,40[0.252]

3,03 [0.119]

0,25 TYP. [0.010]

2

1

4X 0,46 [0.018]

2X 2,23 [0.088]4X 1,27 [0.050]

LN: Single axial barbless port

11,00 [0.433]

7,00 [0.276]4 3

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

5,50 [0.217]

ø3,18[0.125]

PIN 1 INDICATOR

123,50 [0.138]

ø6,40[0.252]

No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60 [0.417]

1,02 [0.040]

2,54 TYP. [0.100] 3 4

2,23 [0.088]

ø0,80[0.032]11,70 [0.461

4X 1,27 [0.050]

0,25 TYP. 3,03 [0.010] [0.119]

2

1

4X 0,46 [0.018]

PN: Low-profile port

11,00 [0.433]PIN 1 INDICATOR

7,00 [0.276]4 3

3,70 MAX. [0.010]2,10 MIN. [0.083]

5,50 [0.217]

ø6,50[0.256]

2,54 TYP.

[0.100]

34

ø0,80[0.032]11,70 [0.461

1

2

3,50 [0.138]

1,02 [0.040]

3,03 [0.119]

0,25 TYP. [0.010]

214X 0,46 [0.018]

2,23 [0.088]4X 1,27 [0.050]

RN: Single radial barbed port

ø1,88[0.07]

7,00 [0.276]43

No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]

5,50 [0.217]

0,9 [0.04]

11,00 [0.433]0,75 [0.030]

ø6,41[0.252]

PIN 1 INDICATOR

123,50 [0.138]

13,00 MAX. [0.512]

2,3 [0.09]

1,02 [0.040]

2,54 TYP.

2,23

[0.100]

[0.088]

34

ø0,80[0.032]11,70 [0.461]

4X 1,27 [0.050]

3,03 [0.119]

0,25 TYP. [0.010]

214X 0,46 [0.018]

4X 0,46 [0.018]TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 12

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

FIGURE 2. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)

VN: Single axial barbless straight port

7,00 [0.276]43

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

No gel coating option: 8,05 [0.317] Silicone gel coating option: 8,30 [0.327]

1,02 [0.040]

2,54 TYP. [0.100]

34

2,23 [0.088]

11,00 [0.433]

5,50 [0.217]

ø2,58[0.101]

ø0,80[0.032]11,70 [0.461

PIN 1 INDICATORRecommended SMT Package PCB Pad Layout2,032 [0.080]

12 3,50[0.138]2,54 [0.100]

7,49 [0.295]

ø6,40[0.252]

3,03 [0.119]

0,25 TYP. [0.010]

SMT PACKAGE PINOUT

PIN

FUNCTION

1

Vsupply

2

Vout-

3

GND

4

Vout+

4X 1,27 [0.050]214X 0,46 [0.018]

1,143 [0.045]

FIGURE 3. LEADLESS SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)

AN: Single axial small barbed port JN: Single radial barbless port

PIN 1 INDICATOR7,00 [0.276]PIN 1 INDICATOR7,00 [0.276]

7,00 [0.276]3,50 [0.138]7,00 [0.276]

No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60 [0.417]

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

3,50 [0.138]

3,56 [0.140]ø1,91[0.075]

ø2,74[0.108]ø2,32[0.091]ø6,40[0.252]

ø0,80[0.032]

0,73 [0.029]6

6X 1,25

5

[0.049]

4

1,02 [0.138]

5X 2,00 [0.079]

0,94 [0.037]

No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]

0,73 [0.029]

3,50 [0.138]

ø0,80[0.032]6

2,00 [0.079] 1,00[0.039]1

2

2,50 TYP.

[0.098]

3

2,00 [0.079]1,00 [0.039]1

13,00 MAX. [0.512]

6X 1,25

5

[0.049]

4

2

2,50 TYP.

[0.098]

3

5X 2,00 [0.079]

0,75 [0.030]

ø6,40[0.252]

2,28 [0.090]

3,50 [0.138]1,02 [0.040]

1,88 [0.074]

KN: Single axial large barbed port

PIN 1 INDICATOR7,00 [0.276]

7,00 [0.276]

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

3,30 [0.130]

3,50 [0.138]

ø3,05[0.120]

3,50 [0.138]

ø4,92[0.194]ø3,81[0.150]

ø6,40[0.252]

No gel coating option: 11,00 [0.433] Silicone gel coating option: 11,25 [0.443]0,73 [0.029]ø0,80[0.032] 6

2,00 [0.079]1,00 [0.039]1

6X 1,25

5

[0.049]

41,02 [0.040]

235X 2,00 [0.079]

2,50 TYP. [0.098]

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 13

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

FIGURE 3. LEADLESS SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)

LN: Single axial barbless port

PIN 1 INDICATOR7,00 [0.276]

7,00 [0.276]

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

3,50 [0.138]3,50 [0.138]

ø3,18[0.125]

6,32 [0.249]ø6,40[0.252]

No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60 [0.417]0,73 [0.029]ø0,80[0.032] 6

2,00 [0.079] 1,00[0.039]1

6X 1,25

5

[0.049]

4 1,02 [0.040]

2 2,50 TYP.[0.098] 35X 2,00 [0.079]

PN: Low-profile port RN: Single radial barbed port

PIN 1 INDICATOR7,00 [0.276]

7,00 [0.276]

3,70 MAX. [0.010]2,10 MIN. [0.083]

3,50 [0.138]

ø6,50[0.256]

3,50 [0.138]

0,73 [0.029]ø0,80[0.032] 6

2,00 [0.079]1,00 [0.039]1

6X 1,25

5

[0.049]

4

2 2,50 TYP. [0.098]3

1,02 [0.040]

5X 2,00 [0.079]

PIN 1 INDICATOR

7,00 [0.276]

ø7,00[0.276]

ø2,32[0.091]

2,3 [0.09]

ø6,40[0.252]

0,96 [0.038]

3,50 [0.138]

13,00 MAX. [0.512]

3,50 [0.138]

3,54 [0.139]

No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]

0,73 [0.029]

ø0,80[0.032]6

ø2,73[0.108]

6X 1,25

5

[0.049]

4

5X 2,00 [0.079]

ø1,91[0.075]

2,00 [0.079]1,00 [0.039]1

2

2,50 TYP.

[0.098]

3

2,3 [0.09]

1,02 [0.040]

VN: Single axial barbless straight port

PIN 1 INDICATOR7,00 [0.276]

7,00 [0.276]

No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]

3,50 [0.138]

ø2,58[0.101]

3,50 [0.138]

ø6,44[0.254]

No gel coating option: 8,05 [0.317] Silicone gel coating option: 8,30 [0.327]

ø0,80[0.032]

0,73 [0.029]6

2,00 [0.079] 1,00[0.039]1

6X 1,25

5

[0.049]

4

2 2,50 TYP. [0.098]3

1,02 [0.040]

5X 2,00 [0.079]

Recommended Leadless SMT PCB Pad Layout

2,54 [0.100]

Gage reference hole: Do not plug.2,50 [0.098]

5,46 [0.215]

1,27 [0.050]

LEADLESS SMT PINOUT

PIN

FUNCTION

1

Vsupply

2

NC

3

Vout-

4

GND

5

NC

6

Vout+

TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 14

TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS

Issue H 50076346

WARRANTY/REMEDYHoneywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application.Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use.

WARNINGRISK TO LIFE OR PROPERTYNever use this product for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that this product is properly rated and installed for the intended use within the overall system.Failure to comply with these instructions could result in death or serious injury.

FOR MORE INFORMATIONHoneywell Advanced Sensing Solutions services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit our website or call:

USA/Canada Latin America Europe Japan Singapore Greater China

+1 302 613 4491 +1 305 805 8188 +44 1344 238258 +81 (0) 3-6730-7152 +65 6355 2828 +86 4006396841

Honeywell Advanced Sensing Technology 830 East Arapaho Road Richardson, TX 75081 sps.honeywell.com/ast

50076346-H-EN | H | 03/21 © 2021 Honeywell International Inc.