Honeywell AQ3CO SENSOR Carbon Monoxide (CO) Gas Sensor User Guide

AQ3COSENSORCarbon Monoxide (CO) Gas Sensor

The purpose of this document is to present the performance specification of the AQ3 Series AQ3CO Carbon Monoxide Gas Sensor.

DOCUMENT PURPOSE

This document should be used in conjunction with the AQ3CO Characterization Note and the Product Safety Datasheet (PSDS 15).The data provided in this document is based on the assumption that the sensor is used at 20°C, 50% rH, and 1013 mBar for three months from the date of sensor manufacture. For guidance on sensor performance outside of these limits, please refer to the AQ3CO Characterization Note.The output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Characterization Note. Sensor Part Number (without board): ABQ045-H00Module Part Number (with board): QAB045-H00PCBA Part Number: AQ3-BP01

FEATURES AND BENEFITS

AQ3CO Carbon Monoxide Gas Sensor Technical Specifications

TECHNICAL SPECIFICATIONS

MEASUREMENT
Technology 4-electrode electrochemical
Measurement Range  0 ppm CO to 10 ppm CO
Maximum Overload without board: 50 ppm COwith the board: 30 ppm CO
Onboard Filter to remove SOx/NOx and H2S
Sensitivity* without board:240 nA/ppm ±80 nA/ppmwith board:90 mV/ppm ±35 mV/ppm
Response Time (T) < 70 seconds
Resolution* 20 ppb when used with recommendedcircuitry
Baseline Offset* without board: -200 nA ~ 360 nAwith board: -80 mV ~ 140 mV
Repeatability* < ±3% of signal
Linearity** linear
Low Detection Limit*  40 ppb
ELECTRICAL
Recommended LoadResistor 68 Ω
Sensor Bias Voltage no bias (without board)
Power Supply Required 5 Vdc (with board)
Power Consumption 370 mA @ 5 Vdc (with board)
MECHANICAL
Weight without board: < 22 gwith board: < 30 g
Outer Plastic BodyMaterial polycarbonate
Sealing GasketMaterial TPU
Contact Material mild steel with gold flash-over nickel plate
Orientation Sensitivity none
ENVIRONMENTAL
OperatingTemperature Range -30°C to 50°C
RecommendedStorage Temperature 0°C to 20°C in an original sealed container
Operating HumidityRange 15% RH to 90% rHnon-condensing
Operating PressureRange atmospheric ±10%
Typical Applications ambient environmental monitoring
LIFETIME
Storage Life 6 months in original sealed container
Long-Term SensitivityDrift* < 10% signal loss per annum
Expected Oper. Life two years in air
Warranty one year

*Specifications are valid at 20°C, 50% RH, and 1013 mbar using AQ3 low noise board. Performance characteristics outline the performance of sensors supplied within the first 3 months. The output signal can drift below the lower limit over time. Please be aware that sensors’ performance is also reflected by circuit board design.** Linear through the concentration range across the whole operational environment range.

All tolerances ±0,15 mm unless otherwise stated

Product Dimensions

Dimensions mm.

All tolerances ±0,15 mm unless otherwise stated

Pin Definition

1 Vin(4.8 V ~ 5.5 V)
2 GND
3 Aux
4 GND
5 Sensing

Filter Information

Removes acid gases such as SOx/NOx and H2 S

Poisoning

Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided, during storage, fitting into instruments, and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted.Do not glue directly on or near the sensor as the solvent may cause crazing of the plastic.

Cross Sensitivity Table

Whilst AQ3 Series gas sensors are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various other gases.The table below is not exclusive and other gases not included in the table may still cause a sensor to react.IMPORTANT NOTE: The cross-sensitivity data shown below does not form part of the product specification and is supplied for guidance only. Values quoted are based on tests conducted on a small number of sensors and any batch may show significant variation. For the most accurate measurements, an instrument should be calibrated using the gas under investigation.

Gas Gas Concentration Cross Interference
Sulfur Dioxide (SO2) 5 ppm 0%<x%<7%
Nitrogen Dioxide (NO2 ) 5 ppm -3%<x%<5%
Ozone (O) 1 ppm -7%<x%<4%
Isobutylene (C4 H8 ) 1 ppm ~None

WARRANTY/REMEDY

Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is the buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.While Honeywell may provide application assistance personally, through our literature and the Honeywell website, it is the buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice.The information we supply is believed to be accurate and reliable as of this writing.However, Honeywell assumes no responsibility for its use.

WARNINGMISUSE OFDOCUMENTATION

  • The information presented in this product sheet is for reference only.Do not use this document as a product installation guide.
  • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

SAFETY NOTEThis sensor is designed to be used in environmental applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before eachuse of the sensor and/or instrument.Failure to carry out such tests may jeopardize the safety of people and Property.

FOR MORE INFORMATION

Honeywell Advanced SensingTechnologies service its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit our website or call:USA/Canada +1 302 613 4491Latin America +1 305 805 8188Europe +44 1344 238258Japan +81 (0) 3-6730-7152Singapore +65 6355 2828Greater China +86 4006396841

HoneywellAdvanced Sensing Technologies830 East Arapaho RoadRichardson, TX 75081sps.honeywell.com/ast

AQ3CO Datasheet ECN 5062 | 002722-1-EN | 1 | 05/21© 2021 Honeywell International Inc.

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by