To ensure your safety, always make sure mains power is switched OFF before accessing wiring.
In case of removing the old thermostat be aware that the existing wiring will no longer be used.
The T6 thermostat should not be placed near draughts, in direct sunlight or near heat sources.
Prepare Receiver Box 2 for installation
Before installation of the Receiver Box
Find a suitable location near to the boiler. Leave at least 30cm distance from any metal objects including wallboxes and boiler housing.
Loosen the front screw to remove cover or tighten it when the cover is back in place.
Needed during installation:
Cable with 2 wires from the boiler to Receiver Box.
The Receiver Box requires 230V power
Install the Receiver Box
Wall box or Rear WiringHinge open the terminal block flap to access the cables and wall box screw holes.
Surface wiringUse the cable clamps to secure the surface wiring.
Replace the coverLocate the hinges at the top of the cover and wall plate, close the cover and secure with the screw.
Install the T6 thermostat
Choose the appropriate plug.Place the thermostat on an even, horizontal surface and plug it in.
Complete installation
Turn ON mains power to the Heating Appliance and Receiver Box.
After power up, SETUP is displayed on the thermostat’s screen.
To rebind the units, reset the Receiver box, then press the button for 3 seconds.The LED on the receiver box will blink yellow to indicate the box is in binding mode. On the thermostat press for 5 seconds to enter the advanced menu. Navigate to Binding, clear the current binding then bind the device again
Set Up and configuration
Touch to begin setting up the thermostat.
Select your language.
Set the clock format, time and date.
Touch to finalise setup. ( to setup using the App is currently unsupported)
Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds.
In the advanced menu the following settings can be adjusted:
Opt. start: 0 = off, 1 = on, 2 = Delayed startOpt. stop: 0 = off, 1 = on
CLOCK
Format: 24h Time: –:– Date: 01/09/16
Clock format: 1 = 12h, 2 = 24h Setup time and date
LOW LOAD CONTROL
ON
0 = off, 1 = on
TEMPERATURE OFFSET
0.0ºC
-1.5 ºC to 1.5ºC
BINDING
–
Bind , check RF and clear bind.
RESET
–
Factory, schedule, WiFi and HomeKit reset
FAILSAFE
OFF
0 = off, 1 = on
Wiring Diagrams
Basic 230V boiler
Combi boiler
OpenTherm boiler* See boiler specifications for correct terminalsFor other wiring diagrams visit:https://hwllhome.co/uk-wiring
Two-port zone valve or S-plan
Customer Support
Need help? For assistance please visit: getconnected.honeywellhome.comResideo, 200 Berkshire Place, Winnersh Triangle, Berkshire RG41 5RPhone: 0300 130 1299
Approvals
Hereby, Pittway Sarl declares that the radio equipment type T6R is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://hwllhome.co/DoC
RF (868MHz): Receiver Category 2, Max RF Power 25mW, 868–868.6MHz (868.3MHz)Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHzErP: Class V (+3%), (EU) 811/2013
Must be installed by a competent person!Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.
WEEE Directive 2012/19/EC Waste Electrical and Electronic Equipment directive
At the end of the product life dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.