Ion Detox Food Spa User Manual

Please keep this manual for future use.

PARTS LIST

OPERATING INSTRUCTIONS

  1. Connect the main frame to the power source, and then connect the parts we provide to the main frame. Make sure that put the fixture in a dry and stable place.
  2. Turn on the machine by pressing down the power button on the back side of the main frame.
  3. Put the arrays into your basin. The water level should completely submerge the array.
  4. It is recommended that add about 0.1g sea salt to the bath water to enhance ionic conduction.
  5. Press the corresponding touch key to start the desired working cycle.

PANEL INSTRUCTIONS

Operating Steps

  1. Once the machine is energized, press the upper A/B MODE button to select the desired working mode.
  2. Press the A/B Time button to select the desired working cycle.
  3. Press button START/STOP to start the working cycle.
  4. Press the ON/OFF button.
  5. Press the lower A/B MODE button to select the desired TENS mode.
  6. Press the button + or – to adjust TENS intensity.
  7. Press the A/B Belt button to select the desired belt function.

NOTE

  • Please select the desired working mode before pressing the START/STOP button. Press the START/STOP button to save all settings and then no setting can be modified.
  • START/STOP button is supposed to control the upper A/B MODE and A/B Time button while the ON/OFF button is supposed to control the lower A/B MODE button and +/- button.
  • TENS refers to Transcutaneous Electrical Nerve Stimulation. It is the use of electric current produced by a the electrode plates to stimulate the nerves for therapeutic purposes, intending to reduce both acute and chronic pain.

MODE INSTRUCTIONS

Mode 1 (+)100%,(-)0%.

Mode 2 (-)100%, (+)0%.

Mode 3 (+)15%, (-)10%, (+)5%, (-)70%.

Mode 4 (-)10%, (+)15%, (-)5%, (+)70%.

Mode 5 (-)50%, (-)50%.

Mode 6 (+)50%, (-)50%;

Mode 7 (-)70%, (+)30%;

Mode 8 (+)70%, (-)30%;

Mode 8 is the most practical working mode which is suitable for most of the people. Press TIME button can adjust working process.

ADJUST THE ION CONCENTRATION VALUE

Ion concentration value is displayed on the lower right corner of the screen. The perfect value range is between 2.5-2.8. If the value is lower than 0.6, the icon which means more salt is needed will flash. If the value is higher than 3.0, the icon which means more water is needed will flash and make beep sound. Either add more water to lower the concentration to 3.0 or adjust the intensity value to 2 or 1. There are three grades of working intensity , if the ion concentration value higher than 3.3, the machine will stop working automatically.

HOW TO USE THE FIR BELT

FIR belt is needed to be connected to the main body at first and then be tied around user’s waist or thigh. Press the belt button to ignite the belt function. The icon which means low intensity will flash. Press belt button again can select Low, Medium and High intensity. The working period of FIR belt is 30 minutes.

HOW TO USE THE TENS PLATES

The tens plates are needed to be connected to the main body at first and then be attached to acupuncture points located on human body. Press the ON/OFF button to ignite the tens plates function. The icon which refers manipulation mode will flash. There are five working modes. Press mode button or can adjust the modes. Icon refers to the working intensity which can be adjusted by pressing + or – button. The working period of tens plates is 30 minutes.

NOTICE

The array will usually be used for 50-60 sessions. When the array stops working, there will be no color turning in the process.

CAUTION

It should never be used by people who are:

Using a peacemaker;2. With a heart condition or epilepsy;3. Pregnant;

TROUBLESHOOTING

SYMPTOM POSSIBLE CAUSE ACTION NEEDED
No values displayed on the screen The Wrist Band enters protection mode Unplug the machine and reboot it.
Press the STOP button and then START button twice. The screen will display values and reboot the wrist band function.
Black Screen/the screen only displays zero The power supply is not connected Check if the power is plugged in.
Fuse burned out Replace the fuse.
The power switch is not turned on Turn on the power source.
The machine stops working The array is not connected. Check if the array is plugged in
The array is broken. Replace the array.

SPECIFICATION

  • Item No.: SUK-805D Power: 130W
  • Frequency: 50Hz-60Hz
  • Electric Current: 0-3.0A
  • Input Power: AC110V
  • Out Power: 0-20V.

Ion Detox Food Spa User Manual – Ion Detox Food Spa User Manual –