JPOWER 12 INCH SHUTTER EXHAUST FAN Instruction Manual

JPOWER 12 INCH SHUTTER EXHAUST
FAN Instruction Manual

INSTRUCTION MANUAL

12 INCH SHUTTER EXHAUST FAN I T EM N O.: V F-1 2 V TPCZLHVE20AB SE READ AND SAVE THIS INSTRUCTION. Attention: Pictures in the IM are for reference only.

READ AND FOLLOW ALL INSTRUCTION BEFORE OPERATING FAN

CAUTION

Read carefully before attempting to assemble, install, operate, or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

WARNING

1. To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.2. The motor amperage and voltage ratings must be checked for compatibility to supply voltage prior to the final electrical connection. Please refer to the motor’s nameplate label.3. This product is to be used indoors.4. Wiring must conform to local, state, and national codes5. This appliance is not intended for use by persons(including children) with reducedphysical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.6. Children should be supervised to ensure that they do not play with the appliance.

RULES FOR SAFE OPERATION

1. Do not depend on any switch as the sole means of disconnecting power when installing or servicing the fan.2. Always disconnect, lock-out, and tag-out power source before installing to or servicing. Failure to disconnect the power source can result in fire, shock, or serious injury.3. Motor will restart without warning after thermal protector trips. Do not touch the operating motor; it may be hot enough to cause injury.4. Do not place body parts or objects in fan or motor openings while motor power is connected to the source.5. All electrical connections should be made by a qualified electrician.6. These utility exhaust fans are for general purpose exhaust applications only. Do not use these exhaust fans in an area where corrosive or explosive materials may be found.7. Follow all local and state/provincial electrical and safety codes in the United States and Canada, as well as the National Electrical Code (NEC) Act and the Occupational Safety and Health (OSHA) in the United States, and the Canadian Electric Code(CEC) in Canada.8. Always disconnect the power source before working on or near a motor or its connected load.9. Protect the power cable from coming in contact with sharp objects.10. Do not kink or create tight bends in the power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals.11. Make certain that the power source conforms to the requirements of your specific exhaust fan model. The fan frame and motor must be electrically grounded to a suitable electrical ground, such as a grounded water pipe or ground wire system.12. To reduce the risk of injury to persons, please observe the following: In the United States, OSHA-compliant guards are required when the fan is installed within 7 feet of the floor or working level. In Canada, CSA-compliant guards are required when the fan is installed below 2.5 meters (8.2 feet) above the floor or grade level.

ASSEMBLY COMPONENTS

Tools / Materials Needed:· Mounting Fasteners (8)· Sealant or Caulk·Regular Screwdriver Set1. The unit should be securely mounted in a rigid framework.

NOTE: Allowing the fan frame to flex or move will result in excess vibrations, which may cause possible premature shutter failure.2. Connect power to the motor using approved wiring methods. Refer to the following wiring diagram: Figure1

The fan frame and motor must be securely and adequately grounded to a suitable electrical ground, such as a groundwater pipe or ground wiring system.Figure1: Wiring Diagram – Single speed. 120-volt connection.

GENERAL SPECIFICATIONS

Dimensions (Inches)

OPERATING INSTRUCTIONS

1. Keep the area free of objects that could impede airflow on both the intake and exhaust side of the fan.2. For proper exhaust operation, a window, door, or louver should be opened for fresh air intake on the opposite side of the area to be ventilated.3. Turn the fan ON; the shutter will open automatically. When the unit is turned OFF, the shutter will close.

MAINTAINANCE

1. Disconnect power source before servicing.2. Periodically clean off accumulated dirt from the propeller, guard, motor, and shutter.

LIMITED ONE-YEAR WARRANTY

JPOWER INC warrants this product to be free of defects in material and workmanship for the applicatons specified in the Owner’s Manual for a period of 12 months for the whole fan from date of purchase. This warranty only applies to the original purchaser of this product.

This warranty excludes damage, accidental or otherwise, to the unit not caused by a defect in material or workmanship.

The warranty also excludes damage caused by misuse, tampering, modification, misassembly, repairs or alterations, or failure to adequately maintain and care for the unit. Operating this product under any conditions other than those recommended or at voltages other than indicated will also void this warranty For warranty issues, contact the place of purchase for repair/ replacement opportunities. The original dated receipt or proof of purchase must accompany all returns.

All warranties, expressed or implied, are limited for 12 months for the whole fan from the date of purchase. JPOWER is a registered trademark of JPOWER INC.

Some states do not allow for the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties. The above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and may also include other rights that vary state by state.E-mail: [email protected]Website: www.jpowerus.com