KENT Mineral RO Water Purifiers Instructions
Dear Customer,
At the outset, allow us to thank you for your trust in KENT water purifier. We take pride in our reputation for product quality and industry proven performance. We are certain that your decision to own KENT Pearl Star Mineral RO TM Water Purifier will go a long way towards keeping you and your family in good health. We are confident that you will be satisfied with its performance and that it will serve your need for safer and cleaner drinking water without any compromise.
This guide will help you in getting the best out of your water purifier. Please go through this booklet to familiarise yourself with its operation and maintenance.
You can look forward to years of trouble-free service. In case you need any further information, contact your nearest KENT dealer or branch.
Best Wishes,
KENT TECHNOLOGY – A Breakthrough in Water Purification
KENT proudly presents KENT Pearl Star Mineral ROT”” Water Purifier its new and advanced domestic water purifier based on the patented KENT Technology.The ground-breaking KENT Technology, developed at KENT laboratory, broadly comprises of state-of-the-art RO+U F+UV with TDS Control & Auto-Flushing System. The initial purification by RO membrane having porosity as fine as 0.0001 microns, reduces even dissolved impurities (hard salts, heavy metals etc.). Double purification by UV process ensures complete protection against bacteria and viruses. Moreover, the patented TDS Control System intelligently retains essential natural minerals in the purified water, thus taking total care of your health and well being.
KENT is pleased to introduce Zero Water Wastage Technology”‘ that recirculates rejected water to overhead tank with its own pump to make it Zero Water Wastage RO. This unique technology helps you make water pure, without wasting any water while retailing essential minerals.
Salient Features of KENT Pearl Mineral ROTM Water Purifier
- Zero Water Wastage
- Purification by RO + UV + OF + TDS Control makes water pure
- Real time monitoring and display of purity on a digital screen
- Suitable for purification of brackish/tap water/ municipal corporation water supply
- Wall mounted / Counter Top design, best suited for Indian homes and offices
- Fully automatic operation, with auto-on/ off function
- Computer controlled operation for enhanced purity and long life
- RO Membrane fused inside membrane housing to prevent tampering
- Use of push-fit fittings for leakage and maintenance free performance
- An aesthetically appealing design
- ABS construction for corrosion free use
- Inbuilt Auto-flushing system
- 11L storage tank with water level indicator
- High purification capacity of 20 L/hr.
Items In The Box
- KENT Pearl Star Water Purifier : 1 N
- 3-Way Connector : 1 N
- S.S. Ball Valve : 1 N
- Food Grade Pipe 0.635 cm (White) : 20 Meters
- Food Grade Pipe % inch (White) : 2.5 Meters
- Bulk Head Union : 1 N
- Fixing Clips : 25 N
- Tie Wire 4 inch : 4 N
- Union Connector : 1 N
- Screws & Plastic Inserts : 2 N each
- Sticker Center Drill : 1 N
- Warranty Card : 1 N
Tested & certified by TUV-SUD South Asia (P) Ltd.Zero Water Wastage is based on the standard testing conditions.
Important Instruction
Reverse Osmosis Process
The Reverse Osmosis process, also known as hyper filtration, is the finest filtration process known till date. The process ensures reduction in particles as small as ions from a solution. Reverse Osmosis uses a semi-permeable membrane to reduce salts from potable/brackish water. In Reverse Osmosis,the water pressure applied to the concentrated side forces the process of osmosis into reverse. Under enough pressure, purer water is “squeezed” through the membrane from the concentrated side to the diluted side. Salts dissolved in water as charged ions are repelled by the RO membrane.The rejected impurities on the concentrated side of the membrane are washed away in a stream of waste water and thus does not get accumulated as in a traditional filter.
UV Process
The UV light has shorter wavelength (higher energy) than visible light. It is called ultra-violet because it is just beyond violet light in the light spectrum. Technically, ultra-violet light is defined to be of any wavelength of light, which is shorter than 400 nanometer.
UV rays, which penetrate into the micro-organisms, are absorbed by the DNA of the pathogen in the water. The DNA is altered in such a way that the pathogen cannot reproduce itself. Thus, it is essentially killed and cannot cause infection. This process of DNA modification is called inactivation.
Auto-flushing System
The purpose of the Auto-flushing system is to help prevent scaling or fouling of the RO membrane by providing a rapid rinse which washes away impurities from the membrane’s surface and keeps the membrane clean. It offers the following benefits.
- Lowers rejected water outflow
- Improves “TDS” rejection rate i.e increases the RO membrane’s efficiency
- Extends the life of the RO membrane
Water Flow Diagram
S.NO. | SPARE PART CODE | ITEM DESCRIPTION |
1 | 20035 | LOW PRESSURE SWITCH |
2 | 20010 | SEDIMENT FILTER |
3 | 20028 | SOLENOID VALVE |
4 | 20005 | BOOSTER PUMP |
5 | 20009 | ACTIVATED CARBON FILTER |
6 | 20003 | OF FILTER |
7 | 20034 | TDS CONTROL VALVE |
8 | 20529 | RO MEMBRANE |
9 | 20020 | FLOW RESTRICTOR TUBE |
10 | 20541 | UV CHAMBER |
11 | 20441 | TDS SENSOR |
12 | 20015 | POST CARBON FILTER |
13 | 20058 | NON RETURN VALVE |
14 | 21871 | WATER STORAGE TANK |
15 | 20030 | WATER LEVEL SENSOR |
16 | 20630 | UV LED |
Electrical Circuit Diagram
S.NO. | SPARE PART CODE | ITEM DESCRIPTION |
1 | 20035 | LOW PRESSURE SWITCH (LPS) |
2 | 21869 | LED DISPLAY |
3 | 20441 | TDS SENSOR |
4 | 21870 | COMPUTER CONTROL BALLAST |
5 | 20028 | SOLENOID VALVE |
6 | 20541 | UV CHAMBER |
7 | 20540 | UV LAMP |
8 | 20030 | WATER LEVEL SENSOR |
9 | 20005 | BOOSTER PUMP |
10 | 20059 | PUMP HEAD |
11 | 20016 | SMPS |
Pearl Star Operation
- Filter life Indicator.
- Kent Logo
- Mineral Content in purified Water
- Warning Indicator
- Service Help Line number
Normal Running Condition
Under normal running conditions and without any fault., the users will be greeted with a screen as shown in figure.
Mineral Content- Good
If the TOS level in the purified water is within the permissible range, the indicator would be in green .zone i.e Good,
Mineral Content -High
If the TDS level in the purified water is more than permissible range, the indicator would be in Red zone. i.e High
Mineral Content- Low
If the TDS level in the purified water is less than permissible range, the indicator would be in yellow zone. i.e Low
No input water
In case of no water input, Kent logo will be blinking, that means no water input.
TDS Sensor Fault
HIGH. GOOD & LOW TDS bands ma be bunking Service call number will be continuous ON No Buzzer Sound for TDS Sensor Fault
UV Lamp Open/Not present
Failure and Call Service Icon will be ON Continuous. Buzzer will beep twice al an Interval of 9 Secs for SO cycles. After 50 cycles buzzer win go OFF
UV tub/intel SV or RO pump/Auto Flush SV fault
Failure and Call Service Icon will be ON Continuously.IN FaultBuzzer wal beep continuously @ 50mSec ON.1.SSoc OFF rate.Islet SV or RO Pomp FaultBuzzer will beep continuously 50mSoc ON,1Soc OFF rate.AF SV Fault.Buzzer will beep continuously @50mSec ON 0.5Sec OFF rate.
Filter Replacement Pre Indication
Service call number will be continuous ON. Filter life last bar will be blinking Buzzer will beep for 4 times at an interval of 2 seconds once for 30 seconds. This will repeat in every 2 Hrs Call service engineer for help
End of Filter life Lock
Service call number will be continuous ON. Filter life all bars will be blinking If Product is in standby mode then Buzzer will turn ON continuous Call service engineer for help
Computer Controlled Operation
To ensure delivery of purer and healthier water, a micro-processor is installed in the purifier that performs the following functions:
UV Stabilization Delay: To ensure that the UV lamp is pre-heated and is working at its optimum level before it starts disinfecting water, the controller provides a two second delay to the UV lamp when the purifier is switched on. During this period, only the UV lamp is switched on and other electrical devices of the purifier are switched off.
Purification Delay: To ensure that the idle water lying in the internal pipes and in the UV chamber is disinfected before being passed into the storage tank, the system provides a 5 second delay when the purifier is switched on. During this time, the UV lamp kills all micro-organisms that may be in the water inside the UV chamber. After this delay, all other electrical devices such as the booster pump and solenoid valve are switched on to start normal purification process.
Alarm: To ensure delivery of purer water, KENT Pearl Star Mineral RO TM Water Purifier in-built micro controller controls and senses various vital components and displays their status on the Display
Automatic Operation
- The purifier automatically shuts off when the storage tank is full
- The purifier automatically flushes & cleans the RO membrane on periodic intervals
- The purifier does not start when inlet water supply pressure falls below 0.3 kg/cm’
- The purifier automatically restarts when water level drops below the maximum
- The purifier does not allow any water rejection in absence of electricity/when tank is full
Installation Instructions
KENT Pearl Star Mineral ROT” Water Purifier is designed to facilitate both wall mounting as well as the counter-top usage. The purifier is easy and convenient to install.
Recommended Site Preparations:
- Single Phase 100-250 V AC, 50-60 Hz. supply not more than 3m away from the point of installation
- Raw water supply with 1/2inch nipple not more than 3m away
- Installation space as per dimensions of the purifier
- For wall mounting installation, make sure that the purifier is mounted on a wall. Avoid installation on wooden and metallic stands
- For optimum inlet pressure, the source water tank should be at least 10 ft above the purifier installed
- Install the purifier near a sink for easy availability of inlet and reject water lines
- The system and installation must comply with state and local laws and regulations.
Installation procedure:
- Paste the central drill sticker on wall at (3.6 feet to 4.0 feet from the ground) as per your convenience.
- Ensure that sticker is pasted straight on the wall ,then drill holes as per the space provided on sticker
- Now, insert the puff up with the help of a hammer.
- Screw in two 10X50 self-taping screws, 5.1 inches (130 mm) apart horizontally.
- Carefully hang the purifier on the wall with the help of the wall-mounting slot holes provided on back side of the purifier.
Note: If the wall is not straight or the screws are not properly drilled in an even position, it will damage your purifier.Note: Keep the device away from heat or direct sunlight.
Step 2
- First fix the SS ball valve (marked as no. 4) to the 114 inch port of the 3-way connecter (marked as no. 2) as shown in figure 2.
- Connect the 3-way connector to the raw water supply (marked as no.1) as shown in the Figure 3. The 3- way connector is fitted in line with the rawwater supply.
- The other end of the 3-way connector can be connected to a tap (marked as no.3) as shown in Figure 4. or can be plugged off if not required.
Step-3
- Now connect one end of the white pipe to the SS ball valve and another end to the upper push-fit elbow fitting to the left hand side of the purifier labelled WATER IN,as shown in fig 1.
- Similarly, connect one end of the white pipe to the lower elbow fitting connector in tank labelled REJECT WATER and leave the other end in the overhead tank,as shown in fig 2.
Step-4
Before connecting the power supply, it is important that you perform the following functions:
- Open the SS ball valve (Handle parallel to the ball valve) to start the flow of waterinto the purifier,as shown in the figure.
- Wait for 2-3 minutes to ensure that the filters are soaked in water.
Step-5
- Connect the power supply.
- Installation is complete.
TDS Adjustment
The unique TDS Control System enables customers to retain the contents of natural minerals (TDS) in purified water, as per their requirement.
- Turning the screw of the valve anti-clockwise, results in an increased mineral content
- Turning the screw of the valve clockwise. results in a decreased mineral content
We recommend keeping the TDS at lowest but not below 50mg/I
Starting up the purifier
- Switch on the power supply
- Allow the storage tank to fill to the maximum level”
- Switch off the power supply
- Open the upper cover. Lift and drain the storage tank so as to remove residual dust particles present in the pipes and storage tank.
- Place back the storage tank and close the upper cover
- Switch on the power supply
- Purifier is ready to use
The glowing Red LED indication power is on. The glowing Green LED indicates the purification is on.
Maintenance
To ensure that the purifier operates at its BEST, routine maintenance must be performed. The frequency of the maintenance will greatly depend upon the raw water quality and consumption of purified water.
- Storage tank must be cleaned once in 2 weeks.
- Replace the sediment filter, activated carbon filter & post carbon filter once in 12 months or whenever the filter change alarm activates. It is recommended to change FRT along with the filters.
- Replace the RO membrane once in a year I Replace the UV Lamp once in a year
- In the event of not using purifier for a long time (while going for a holiday, tour etc.), make sure that you disconnect the power supply, turn off the raw water supply and drain the storage tank
The replacement time of consumables such as filters and membrane is dependent on the quality of raw water and water consumed.
The Reverse Osmosis system contains a replaceable treatment component critical for the effective reduction of total dissolved solids and that product water shall be tested periodically to verify that the system is performing properly.
Tested 8 Certified by TUV-SUD South Asia (P) Ltd.Tested or certified flushing time – 24hrs.
Replacement of spare parts are as under:
- 20010: SP InlineSedimentFilter 8″
- 20009: SP InlineCarbonFilter 8″
- 20529: SP RO Membrane
- 20015: SP PostCarbonFilter(Blue)
- 20003: SP Hollow Fibre Membrane
- 20020: SP FRT300/450
Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of raw water and water consumption. They are not covered under the warranty. However. if a filter chokes within six months and a membranewithin a yeacit will be cleaned/repaired/replaced free of cost. Changing the filters and system inspection is available on call. The treatment capacity of RO membrane will reduce with time due to clogging of pores of membranes.
This Reverse Osmosis system contains a replaceable component critical to the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical specifications as defined by the ma nufacturecto ensure the same efficiency and contaminant reduction performance.”
Important Safety Instructions
- If the supply cord is damaged, it must be replaced by the original part in order to avoid hazard
- Children should be supervised to ensure that they do not play with the appliance
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety
Warning
- Do not operate the UV-C emitter when it is removed from the appliance enclosure
- Read the maintenance instructions before opening the appliance
- The appliance must be disconnected from the supply before replacing the UV-C emitter
Technical Specification
Purification capacity tested on tap having TDS level of 750 ppm at room temperature.
Testing Information
The System has been tested according to IS 10500:2012 (Standards for drinking water as per Bureau of Indian Standards) for reduction of the hazardous substances as listed below.