KingFisher 3663602522492 3 Section 12 Tread Insulated Hatch Folding Loft ladder Kit Instruction Manual

Instruction Manual

These products comply with the European Standard EN14975:2006+A1:2010.

Weight of the ladder.

During steps 1 and 2 the wood screws must be fitted manually using a screwdriver. DO NOT over-tighten the screws as this can cause the screws to lose their grip on the timber and in serious cases, fall out.

Assembly

During steps 1 and 2 the wood screws must be fitted manually using a screwdriver. DO NOT over-tighten the screws as this can cause the screws to lose their grip on the timber and in serious cases, fall out.During steps 1 and 2 the wood screws must be fitted manually using a screwdriver. DO NOT over-tighten the screws as this can pay cause the screws to lose their grip on the timber and in serious cases, fall out.

DO NOT use the ladder if all sections of the ladder are not aligned.

Safety & Installation

IMPORTANT! PLEASE READ ALL THESE INSTALLATION INSTRUCTIONS BEFORE STARTING TO INSTALL YOUR LOFT LADDER.

The ladder should be high enough to allow you to climb up into the loft without exceeding the maximum permitted safe working height. The ladder must bear a load corresponding to the weight of the fitter plus the weight of the loft ladder.Do not use the ladder as an access passage during building or renovation work. Do not use the ladder if the ceiling height exceeds the maximum ceiling height stated in the installation instructions or on the product label.For safety’s sake, always face the ladder when climbing up and down and grip at least one string of the ladder. The ladder must be used only by one person at a time.Do not use the ladder if it is faulty or damaged. The springs are very taut. Take care when adjusting springs. Only adjust the spring mechanism when the ladder is folded (i.e. the springs are under the least tension). Great care should be taken when removing springs. If the ladder is delivered unassembled, read the assembly instructions carefully before assembling and installing the ladder. The ladder is tested to 150kg (maximum load). A load in excess of 150kg may cause damage to the ladder and constitutes a risk of personal injury.NB! Lubricate all moving metal parts with oil immediately after assembly. Parts must subsequently be lubricated at least once a year.

  1. Fitters, tools, and materials:We recommend that 2 fitters install the loft ladder together. One fitter must be strong enough to lift the loft ladder to the ceiling (as the loft ladder weighs up to 24.3kg  (EAN: 3663602522492) / 25kg (EAN: 3663602548133).
  2. Installation instructions:To ensure that the product is assembled and fitted correctly, these instructions should be followed carefully.If you have any difficulties, contact an expert for installation advice.WARNING: DO NOT DISMANTLE the loft ladder once it has been assembled.NB! For models in which the ladder is fixed to the trapdoor. If, during installation, you wish to detach the ladder to reduce the weight of the loft ladder, loosen the screws between the metal bracket and the ladder itself. Do not loosen the screws on the trapdoor as these can easily be overtightened when reassembled.AN OVERTIGHTENED SCREW MAY LOSE ITS GRIP ON THE TIMBER AND, IN SERIOUS CASES, FALL OUT.Positioning the loft ladder:
    EAN A(cm) B(cm) C(cm)
    3663602522492 127 162 277
    3663602548133 127 162 279

    Wear gloves when removing insulation material. Check that the area selected for positioning the ladder is unencumbered by electrical wiring, water pipes, heating/ cooling pipes, etc. If necessary, get a qualified craftsman to remove such encumbrances. Make sure that there is sufficient clearance (distance A) for the ladder to rest on the floor.  Make sure that there is sufficient space for the ladder to fold out to its full length (B) (see figure 1). For two-section models, make sure that there is sufficient swing space.  For specific measurements and adjustment options, see the assembly instructions supplied with the product.

  3. To make the opening in ceiling:We recommend that you wear goggles and a mask for protection from falling dust and other particles from the loft. Remove all items of furniture from the work area. Cover the floor. Frame and cut the opening through plaster/other ceiling material (see table 1). This allows space for spacer blocks and ensures that the loft ladder is fitted perpendicularly. If the loft ladder cannot be fitted in the normal way. e. parallel with the ceiling joists, contact a qualified craftsman for advice. Figures 2, 3 and 4 show how  to frame the ceiling opening.
    EAN Length (cm) Width (cm)
    3663602522492 115 57.4
    3663602548133 120 60

    If you fit the loft ladder parallel to the existing ceiling joints, only single ceiling joists and single transverse joists are required. If you fit the loft ladder at right angles to the joists, you will need to make double transverse joists of the same size as the existing ceiling joists.WARNING: If the ceiling joists are made in a material other than timber, e.g. steel, contact a qualified craftsman. Never saw through a load-bearing joist without advice from a qualified craftsman. Take great care when sawing ceiling joists. For safety’s sake, if there is no loft flooring, lay planks across the ceiling joists to allow safe passage in  the loft during installation.

  4. Fitting temporary supports:To keep the loft ladder in place in the ceiling opening during installation, you are advised to fit temporary supports. If the trapdoor will be clad, the loft ladder must be fitted as many mm higher in the opening as the thickness of the cladding. Cladding material must not weigh more than 6kg per m². Cladding material must not be more than 12mm thick. We recommend that the cladding is affixed using construction adhesive.WARNING: It is important that cladding is fitted firmly and correctly. When affixing cladding, the ladder must NOT be loaded
  5. Attaching the loft ladder:One fitter goes up into the loft room, taking all the tools he needs. The other fitter remains below.Lift the ladder up into the loft. Before lowering the loft ladder into the opening from above, attach 2 supporting planks under the ceiling opening. The loft ladder rests on these supports (see figure 5). Fold the ladder so that the frame can be attached to the ceiling opening. Make sure that the loft ladder is level and perpendicular. Attach loft ladder with adequate screws, allow at least half the total screw length to penetrate the support joists, specified within Assembly  Step ’05’ on page 5 (3 on long side and 2 at each end). Don’t forget to attach blocks on the back of the fixing points (see figure 6). When the loft ladder is firmly attached, remove supports.WARNING: DO NOT use the loft ladder before it is firmly attached to the opening and adjusted to the correct ceiling height.Vapor barrier: When the loft ladder is firmly attached to the deck, the vapor barrier must be attached in the correct way. The space between the loft ladder and the joist construction must be well-insulated to avoid thermal bridges.
  6. Adjusting to correct ceiling height:Refer to step 9, 10 and 11 from assembly instructions for detail on adjusting the length of the ladderWARNING: DO NOT SHORTEN THE LADDER TOO MUCH.If the ladder is too short, it may unexpectedly fold up during use, thus risking serious personal injury. To check that the ladder is the correct length, unfold it to its full length. All sections of the ladder must be aligned perfectly with no gaps, and both strings must rest flat on the floor (see figure 8).WARNING: DO NOT USE THE LADDER IF ALL SECTIONS OF THE LADDER ARE NOT ALIGNED.If the ladder is too long, shorten the strings once more. If the ladder is too short, order a new lower section from your dealer. DO NOT allow the ladder to rest on a box,  blocks, platform or similar. Such constructions are unsafe and unstable and do not provide appropriate permanent support for the ladder 
  7. How to use the ladder:The following drawings show how to use the loft ladder safely (see figure 9).NOTE: If your building construction differs from the installation guide above, consult an expert.WARNING: Never modify the product. The manufacturer accepts no liability whatsoever for personal injury or damage caused to the building or parts thereof by a  product, whose construction has been modified. 

Safety & Operation

Pre-Use and periodic checks

  • Check stiles and treads are not split, warped, bowed, loose, rotten or otherwise damaged.
  • Check all screws, bolts, and nuts are secure and tight (do not overtighten).
  • Check trapdoor locks into position correctly.
  • Check metal parts are not corroded or otherwise damaged.
  • Check all hinges operate smoothly (lubricate periodically – see label on trapdoor).
  • Check ladder sections operate smoothly when opened.
  • Check ladder sections are straight when fully opened.
  • Check ladder feet rest firmly on the floor.
  • Check ladder sections are flat and correctly positioned once folded.

Use

  • Never use this loft ladder for purposes for which it has not been designed, such as trade or building work.
  • Never use this product unless it has been fully, and correctly, installed.
  • Fully open the trapdoor before unfolding the ladder.
  • Ensure the springs and connecting wires have not become trapped or snagged.
  • Ensure the springs and connecting wires are correctly positioned and are secure.
  • Fully unfold ladder before use.
  • Ensure any catches or locks are fully engaged before ascending the ladder.
  • Ensure both ladder feet rest firmly on the floor before climbing the ladder.
  • Inspect the ladder before climbing (see above) – do not use if damaged.
  • Only wear suitable footwear whenever ascending or descending the ladder.
  • Maintain 3 points of contact by gripping the handrail or ladder stiles when ascending or descending.
  • Do not overload the ladder by carrying heavy objects.
  • Take care when carrying awkwardly shaped objects up and down the ladder.
  • Keep a firm grip on anything being carried to prevent the object from falling.
  • Only ascend and descend the ladder by facing the treads.
  • Never exit the ladder by stepping away from the treads.
  • Ensure the trapdoor is securely locked after use.

Care & Maintenance

Repair & Maintenance

  • Repairs and maintenance shall be carried out by a competent person and be in accordance with these instructions. NOTE: A competent person is someone who has the  skills to carry out repairs or maintenance, eg. trained by the manufacturer.
  • For repair and replacement of parts, e.g. feet, springs and hooks, contact your supplier or distributor.
  • Ladders shall always be operated in accordance with the producer’s instructions.
  • Timber loft ladder stiles and treads should not be painted or varnished.
  • Periodically lubricate all moving parts with light oil.
  • Periodically clean all timber parts to prevent the build-up of dirt, grease and other contaminants.
report this ad

TraceabilityFor traceability purpose it can be identified by the barcode (EAN) number and also manufacturing date or serial number, these can be found on the trapdoor.

LL1T A Product contains

Manufacturer3 Sheldon Square, London, W2 6PX,United KingdomKingfisher International Products Limited,EU Manufacturer:Kingfisher International Products B.V.Rapenburgerstraat 175E1011 VM AmsterdamThe Netherlandswww.kingfisher.com/productswww.diy.comwww.screwfix.comwww.screwfix.ieTo view instruction manuals online,visit www.kingfisher.com/products