LiftMaster Star1000EV Access Control Receiver User Guide

Model Star1000EVAccess Control Receiver

NOTE:The original installation and operating instructions were compiled in English.Any other available language is a translation of the original English version.

APPLICATION

The STAR1000EV is a high-capacity single channel access control receiver for door operators, and dry contact triggered devices. The STAR1000EV is compatible with EVO Code (Security+ 2.0™   remote controls. The receiver capacity is 1,000 devices and can be any combination of remote controls and wireless keyless entries. The receiver is watertight according to IP44 specification. This receiver is compatible with HomeLink®.

INSTALLATION

  1. Select a convenient location near the operator to be controlled by the receiver within the “line of sight” of the intended transmitting location.NOTE: Do not mount LCD screen in direct sunlight. Avoid mounting the receiver in a metal enclosure or near other wireless receiving or transmitting devices.
  2. Mount the bracket to the desired surface with appropriate hardware (not provided) (Fig. 1).
  3. Remove the 4 screws on the back of the receiver and remove the faceplate. Unplug the keypad connector from the control board.NOTE: Be careful not to damage the keypad cable while removing the faceplate.
  4. Make wiring connections (Figure 2). Refer to your gate or commercial door operator owner’s manual for more specific information.
  5. Reconnect the keypad connector to the board (labeled J9).
  6. Secure the faceplate with the 4 screws previously removed.
  7. Install the antenna provided.NOTE: Use an antenna extension kit to mount the remote antenna as high and far from metallic objects as possible for the best radio range.
  8. Snap the receiver onto the mounting bracket and secure with the screws provided.
  9. Tighten the watertight connector to secure and seal the wiring.

USER INTERFACE

The STAR1000EV user interface consists of a 22 character by 5 lineLCD display, 3 “soft keys”, Down/Up arrows, and a numeric keypad.

WARNINGTo prevent possible SERIOUS INJURY or DEATH from electrocution:

  • The installer (specialist) must carefully read and understand these instructions before starting any work.
  • Be sure power is NOT connected BEFORE installing the receiver.To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:
  • ALWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control transmitters.
  • Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
  • ALWAYS keep the gate or garage door in sight until completely closed.NEVER permit anyone to cross the path of the moving gate or door.
  • The STAR1000EV must be installed at a height below 2 m.
  • An All-pole mains switch is required to be incorporated in the electrical installation of the building.

WARNINGTo prevent possible SERIOUS INJURY or DEATH, the use of CONSTANT OPERATION on residential openers is PROHIBITED. The receiver can be installed on door operators which comply with the essential standards EN12453, EN 60335-2-92, and E60335-2-103.

PROGRAMMING

The receiver has the ability to learn a combination of remote control transmitters and keyless entries up to 1,000 devices. Audible and visual warnings occur when the receiver’s capacity is exceeded. After 30 seconds of inactivity, the receiver times out, and the LiftMaster® logo is displayed. Select “UNLOCK” and enter the PIN to continue.

The initial PIN set up:

The PIN restricts access to authorized administrators only. If you omit this step, anyone will be able to program the receiver. Upon initial power-up, the system firmware revision is displayed for 5 seconds followed by the LiftMaster® logo. When a key is pressed, “CREATE PIN?” is displayed.

  1. Press “YES” to create a PIN. If the PIN is lost you may request a reset code by pressing “RESET”.
  2. Enter a 6-digit PIN, and press “YES”; enter the 6-digit PIN a second time and press “YES” to program the PIN. If you make a mistake, press “CLEAR” to change your entry. To exit the enter PIN screen, select “BACK”.
  3. When your 6-digit PIN is programmed correctly, the LCD display reads “KEYPAD UNLOCKED”. Select “OK” to continue to the Main Menu. After 30 seconds of inactivity, the receiver times out, and the LiftMaster® logo is displayed. Select “UNLOCK” and enter a PIN to continue.

PROGRAMMING COMMANDS*

The table below describes the commands used to program the receiver.

MAIN MENU COMMAND DESCRIPTION
LEARN MENU LEARN DEVICE Program a device to the receiver.
LEARN TO LOC # Program a device to a 4-digit number location.
DELETE MENU DELETE DEVICE Delete a specified device that has been programmed to the receiver.
DELETE ALL DEVICES Delete all programmed devices.
SUSPEND MENU SUSPEND DEVICE Temporarily disables the function of a specified device that has been programmed to the receiver.
SUSPEND ALL DEVICES Temporarily disables the function of ALL devices programmed to the receiver.
UNSUSPEND DEVICE Re-enable the function of a suspended device.
UNSUSPEND ALL DEVICES Re-enable the function of ALL suspended devices.
QUERY MENU LOC # USED Displays a range of used locations starting from a specified location.
LOC # AVAILABLE Displays a range of empty locations starting from a specified location.
LOC # SUSPENDED Displays a range of suspended locations starting from a specified location..
SETTINGS CHANGE PIN Change the 6-digit PIN number for the receiver.
DEALER INFO Display and edit the dealer contact phone number.
FIRMWARE VERSION Displays the current firmware version.
BEEP Turn the audible feedback on or off.
MEMORY DUPLICATE MEMORY Creates a memory backup. A backup memory module must be installed.
RESTORE MEMORY Restores a memory backup from a memory module.NOTE: Content of memory backup module will overwrite any information already stored in the receiver memory.
RELAY Sets the relay activation time from .25 to 1 second.
CONTRAST Press Down or Up arrows to adjust LCD contrast.
LANGUAGE Sets menu language: English (Default), Spanish, and French.
FACTORY DEFAULT Reset receiver to factory default settings.

*Further information: Liftmaster. EU

SPECIFICATIONS

System Capacity………………………………………………………………..1000 devicesSupply Voltage………………………………………………………………….9 – 30 Volts AC, 9 – 42 Volts DCOperating Current……………………………………………………………… 50 mA MaximumStand By Current………………………………………………………………. 30 mA MaximumSurge Suppression…………………………………………………………….6.0 kV MinOperating Temp Range………………………………………………………-40°C to +65°C @ 50% RhStorage and Shipping Temp Range………………………………………-40°C to +85°C @ 50% RhFrequency…………………………………………………………………………EVO Code, Security+ 2.0™ (433, 868 MHz)Relay Contact Rating…………………………………………………………. 1 amp @ 24V AC/DC

COMPATIBLE ACCESSORIES*Remote Controls………………………………………………………………..TX2EV/S, TX4EV/S/F, TX4UNI/S/FKeypads…………………………………………………………………………… 747EV12 V DC Transformer**(optional, indoor use only) ………………UPS-TDX* Compatible list: Liftmaster. EU**Power supply must be used according to IEC62368-1 Type PS2.(Optional – 12 V DC Transformer Model TDX-1200500 indoor use only (SKU: UPS-TDX)

EVENT AUDIBLE NOTIFICATIONS ON/OFF
Keypress Single YES
Successful Add Double
Successful Delete Triple
Successful Suspend Double
Successful Unsuspend Double
Master PIN entry error Long
Programming error Long
Location out of range Long
Generic Success Double
Generic Error Long
Received unknown Tx Slow YES
Received known Tx Double YES
Received known suspended Tx Long YES

DIAGNOSTICS

The receiver emits a series of audible beeps to signal programming and error events. The table at right lists all of the events and their audible notifications. The On/Off column indicates that the audible notification for the event may be disabled in the BEEP SETTINGS menu.The packaging must be disposed of in the local recyclable containers. According to the European Directive 2002/96/EC on waste electrical equipment, this device must be properly disposed of, after usage in order to ensure recycling of the materials used. Old accumulators and batteries may not be disposed of in the household waste, since they contain pollutants and must be properly disposed of in municipal collection points or in the containers of the dealer provided. Country-specific regulations must be observed.Hereby, Chamberlain GmbH declares that the access control receiver-type Star1000EV is in compliance with Directive 2014/53/EU.The full text of the EU declaration of conformity is available at the following internet address: https://chamberlain.de/Chamberlain/media/Chamberlain/CE/DoC_Star1000EV.pdf

http://www.liftmaster.euChamberlain GmbHSaar-Lor-Lux-Str. 1966115 SaarbrückenGermanyWEEE-Reg. Nr. DE66256568www.liftmaster.eu[email protected]

report this ad

2020, all rights reserved114-5343

References