Model Star1000EVAccess Control Receiver
NOTE:The original installation and operating instructions were compiled in English.Any other available language is a translation of the original English version.
APPLICATION
The STAR1000EV is a high-capacity single channel access control receiver for door operators, and dry contact triggered devices. The STAR1000EV is compatible with EVO Code (Security+ 2.0™ remote controls. The receiver capacity is 1,000 devices and can be any combination of remote controls and wireless keyless entries. The receiver is watertight according to IP44 specification. This receiver is compatible with HomeLink®.
INSTALLATION
- Select a convenient location near the operator to be controlled by the receiver within the “line of sight” of the intended transmitting location.NOTE: Do not mount LCD screen in direct sunlight. Avoid mounting the receiver in a metal enclosure or near other wireless receiving or transmitting devices.
- Mount the bracket to the desired surface with appropriate hardware (not provided) (Fig. 1).
- Remove the 4 screws on the back of the receiver and remove the faceplate. Unplug the keypad connector from the control board.NOTE: Be careful not to damage the keypad cable while removing the faceplate.
- Make wiring connections (Figure 2). Refer to your gate or commercial door operator owner’s manual for more specific information.
- Reconnect the keypad connector to the board (labeled J9).
- Secure the faceplate with the 4 screws previously removed.
- Install the antenna provided.NOTE: Use an antenna extension kit to mount the remote antenna as high and far from metallic objects as possible for the best radio range.
- Snap the receiver onto the mounting bracket and secure with the screws provided.
- Tighten the watertight connector to secure and seal the wiring.
USER INTERFACE
The STAR1000EV user interface consists of a 22 character by 5 lineLCD display, 3 “soft keys”, Down/Up arrows, and a numeric keypad.
WARNINGTo prevent possible SERIOUS INJURY or DEATH from electrocution:
- The installer (specialist) must carefully read and understand these instructions before starting any work.
- Be sure power is NOT connected BEFORE installing the receiver.To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:
- ALWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control transmitters.
- Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
- ALWAYS keep the gate or garage door in sight until completely closed.NEVER permit anyone to cross the path of the moving gate or door.
- The STAR1000EV must be installed at a height below 2 m.
- An All-pole mains switch is required to be incorporated in the electrical installation of the building.
PROGRAMMING
The receiver has the ability to learn a combination of remote control transmitters and keyless entries up to 1,000 devices. Audible and visual warnings occur when the receiver’s capacity is exceeded. After 30 seconds of inactivity, the receiver times out, and the LiftMaster® logo is displayed. Select “UNLOCK” and enter the PIN to continue.
The initial PIN set up:
The PIN restricts access to authorized administrators only. If you omit this step, anyone will be able to program the receiver. Upon initial power-up, the system firmware revision is displayed for 5 seconds followed by the LiftMaster® logo. When a key is pressed, “CREATE PIN?” is displayed.
- Press “YES” to create a PIN. If the PIN is lost you may request a reset code by pressing “RESET”.
- Enter a 6-digit PIN, and press “YES”; enter the 6-digit PIN a second time and press “YES” to program the PIN. If you make a mistake, press “CLEAR” to change your entry. To exit the enter PIN screen, select “BACK”.
- When your 6-digit PIN is programmed correctly, the LCD display reads “KEYPAD UNLOCKED”. Select “OK” to continue to the Main Menu. After 30 seconds of inactivity, the receiver times out, and the LiftMaster® logo is displayed. Select “UNLOCK” and enter a PIN to continue.
PROGRAMMING COMMANDS*
The table below describes the commands used to program the receiver.
MAIN MENU | COMMAND | DESCRIPTION |
LEARN MENU | LEARN DEVICE | Program a device to the receiver. |
LEARN TO LOC # | Program a device to a 4-digit number location. | |
DELETE MENU | DELETE DEVICE | Delete a specified device that has been programmed to the receiver. |
DELETE ALL DEVICES | Delete all programmed devices. | |
SUSPEND MENU | SUSPEND DEVICE | Temporarily disables the function of a specified device that has been programmed to the receiver. |
SUSPEND ALL DEVICES | Temporarily disables the function of ALL devices programmed to the receiver. | |
UNSUSPEND DEVICE | Re-enable the function of a suspended device. | |
UNSUSPEND ALL DEVICES | Re-enable the function of ALL suspended devices. | |
QUERY MENU | LOC # USED | Displays a range of used locations starting from a specified location. |
LOC # AVAILABLE | Displays a range of empty locations starting from a specified location. | |
LOC # SUSPENDED | Displays a range of suspended locations starting from a specified location.. | |
SETTINGS | CHANGE PIN | Change the 6-digit PIN number for the receiver. |
DEALER INFO | Display and edit the dealer contact phone number. | |
FIRMWARE VERSION | Displays the current firmware version. | |
BEEP | Turn the audible feedback on or off. | |
MEMORY | DUPLICATE MEMORY | Creates a memory backup. A backup memory module must be installed. |
RESTORE MEMORY | Restores a memory backup from a memory module.NOTE: Content of memory backup module will overwrite any information already stored in the receiver memory. | |
RELAY | Sets the relay activation time from .25 to 1 second. | |
CONTRAST | Press Down or Up arrows to adjust LCD contrast. | |
LANGUAGE | Sets menu language: English (Default), Spanish, and French. | |
FACTORY DEFAULT | Reset receiver to factory default settings. |
*Further information: Liftmaster. EU
SPECIFICATIONS
System Capacity………………………………………………………………..1000 devicesSupply Voltage………………………………………………………………….9 – 30 Volts AC, 9 – 42 Volts DCOperating Current……………………………………………………………… 50 mA MaximumStand By Current………………………………………………………………. 30 mA MaximumSurge Suppression…………………………………………………………….6.0 kV MinOperating Temp Range………………………………………………………-40°C to +65°C @ 50% RhStorage and Shipping Temp Range………………………………………-40°C to +85°C @ 50% RhFrequency…………………………………………………………………………EVO Code, Security+ 2.0™ (433, 868 MHz)Relay Contact Rating…………………………………………………………. 1 amp @ 24V AC/DC
COMPATIBLE ACCESSORIES*Remote Controls………………………………………………………………..TX2EV/S, TX4EV/S/F, TX4UNI/S/FKeypads…………………………………………………………………………… 747EV12 V DC Transformer**(optional, indoor use only) ………………UPS-TDX* Compatible list: Liftmaster. EU**Power supply must be used according to IEC62368-1 Type PS2.(Optional – 12 V DC Transformer Model TDX-1200500 indoor use only (SKU: UPS-TDX)
EVENT | AUDIBLE NOTIFICATIONS | ON/OFF |
Keypress | Single | YES |
Successful Add | Double | |
Successful Delete | Triple | |
Successful Suspend | Double | |
Successful Unsuspend | Double | |
Master PIN entry error | Long | |
Programming error | Long | |
Location out of range | Long | |
Generic Success | Double | |
Generic Error | Long | |
Received unknown Tx | Slow | YES |
Received known Tx | Double | YES |
Received known suspended Tx | Long | YES |
DIAGNOSTICS
The receiver emits a series of audible beeps to signal programming and error events. The table at right lists all of the events and their audible notifications. The On/Off column indicates that the audible notification for the event may be disabled in the BEEP SETTINGS menu.
http://www.liftmaster.euChamberlain GmbHSaar-Lor-Lux-Str. 1966115 SaarbrückenGermanyWEEE-Reg. Nr. DE66256568www.liftmaster.eu[email protected]
References