COL50 Bluetooth Control Box
BL1 end plate kit with cable through: Top plate dimensions:
Motor cable
Bottom plate dimensions:
Hand control cable
Hand control cablePlease notice the thickness of the bottom plate is 12 mm . The thickness of the bottom plate without connections is 10 mm . Bottom plate dimensions:Motor cableDrawing no .: 0801263-ABL1 Mounting guidelines: · BL1 is for use in push applications, and can be mounted in both directions (smallest profile down, or up) .Note: The cable outlet can be positioned at the top (smallest profile) . If the option with integrated cable is chosen, the cable outlet can also be positioned at the bottom (biggest profile) . · It is very simple to mount the BL1 in the application using the 4 mounting holes in both endplates . · Use 4 self-tapping screws, in each end, for mounting to the application . Use EJOT PT type DG Ø8, screw depth must be min . 30 mm in aluminium profile . Screw torque: 15 – 17 Nm . · If the column has been loosened from the application, it is very important that the self-tapping screws are mounted in the same thread, to ensure the same strength in the thread . Therefore we recommend that the screws are loosened no more than 1 or 2 times .Page 81 of 264
0.8
Mounting holes 0.6Mounting holes Mounting of BL1 with cable through:Mounting holes
Mounting holes Drain hole
Drain hole
Mounting holes
Drawing no .: 0807000-1
Mounting holes Drain hole
Mounting holes
Drain hole
Mounting holes Page 82 of 264
Drawing no .: 0807001-1
Recommendations· The mounting plate in the application must cover the entire top plate of the BL1 and be strong enough to carry the load . · Remember to secure the cable mounted in the top of the column to the application, so that it cannot be pulled out of the column .We recommend to use LINAK Cable: – Lock kit for BL1 with motor cable: 0808040 – Lock kit for BL1 with hand control cable through: 0808046 Use only the screws included in the kit . · For motor cable mounted at the top, use the long screw with the coarse thread . Screw torque 1 .7 Nm . · For motor cable mounted at the bottom and for cable through, use the short screw with the fine thread . Screw torque 2 .7 Nm . · Electro Static Discharges! There is no electrical connection through the length of the BL1 column . Therefore, to avoid ESD issues, consider external potential alignment between the top and bottom of the bed frame . To connect for further earth wiring in the application, use an appropriate ø8 mm cable shoe under one of the 8 mm screws at both the top plate and the bottom plate . · Remember to mount the blind plugs in the top plate if the motor cable is connected from the bottom plate to ensure the IPX6 protection .
When mounting more than one BL1 you need to consider the fixation: Fixed pivot point
Moveable pivot point
Example 1 .
Example 2 .
Fixed pivot point
Fixed pivot point
The reason why it is important only to fix one column, is that the columns will not move exactly in parallel even if you have positioning such as hall . If more than one column is fixed it can lead to dangerous situations .
If you have a trend/anti-trend function in your application, you need to mount one or more BL1s with a slider . Having sliders prevents the column from bending as illustrated below .
Page 83 of 264
2. LC3 (MEDLINE® CARELINE® )
The LC3 2-stage and 3-stage set the standard for vertical lifting columns to high-end medical applications . This compact lifting column fulfils the market requirements for a solid and stable lifting column .
Usage:
· Duty cycle: 10%, 2 minutes continuous use followed by 18 minutes not in use
· Operation temperature:
+5 °C to + 40 °C
· Storage temperature:
-40 °C to + 70 °C
· Compatibility:
Compatible with LINAK control boxes .
Please contact LINAK .
· Relative humidity:
20% to 80% – non-condensing
· Atmospheric pressure:
700 to 1060 hPa
· Meters above sea level:
Max . 3000 meters
· Approvals:
IEC 60601-1
IEC 60601-1-6
ANSI/AAMI ES60601-1
CAN/CSA-C22 .2 No . 60601-1
LC3 mounting guidelines LC3 is for use in push or pull applications and can be mounted in both directions largest profile down or largest profile up . LC3 must be specified for specific mounting direction .Mounting direction according to item number nomenclature .
Observe no drain holes
Top plate up IPX4
Top plate down
Observe no drain holesIPX4IPX6
Observe drain holes
Observe no drain holes
IPX6 is only available when LC3 is mounted with the largest profile up . IPX6 is only applicable when the LC3 column is fully retracted . Note: The cable outlet for motor connection can be positioned at the top (smallest profile) or from the side of the column .
Page 84 of 264
LC3 mounting guidelinesIf you want to use the column with a high off-center load, we recommend that you install the weight in one of the 3 ways illustrated by the green symbols . It is not recommended to install the weight on the opposite side of the mechanical endstop as illustrated with the red symbol . This installation can create an uneven movement when the lifting column reaches the endstop position .
Mechanical endstop
Use 4 pcs . M10 8 .8 screws, in each end, for mounting to the application . The screw depth must be min . 20 mm and max . 30 mm in aluminum profile . Screw torque: 35 Nm . LC3 3-Stage
15 mm distance to thread
Screw depth min . 20 mm
3 mm distance to thread
Mounting holes, top
Mounting holes, bottom
Page 85 of 264
Drawing no .: 1002W9005
Use 4 pcs . M10 8 .8 screws, in each end, for mounting to the application . The screw depth must be min . 20 mm and max . 30 mm in aluminum profile . Screw torque: 35 Nm . LC3 2-Stage
15 mm distance to thread
Screw depth min . 20 mm
3 mm distance to thread
Mounting holes, top
Mounting holes, bottom
Drawing no .: 1002W9008Notice that the cable plug must be mounted correctly . The cable slot must fit into the socket .Remember to secure the cable mounted in the top of the column to the application, so that it cannot be pulled out of the column . We recommend to use LINAK Cable: · Lock kit for minifit cable: 1002W8136-A . · Lock kit for hand control cable through: 1002W8137-AUse only the screws included in the kit . Screw torque: 2 NmThe cables coming out of the side of the column should follow below guidelines . The internal radius should not be more than 3 times the outer dimension OD – of the cable . For instance if the outer cable dimension is Ø7, the internal radius of the maximum cable bending is 21 mm .
· LC3 3-stage – protective grounding cable LC3 has potential equalization between top and bottom plate but the middle profile is not grounded .· It is recommended to use screws with thread-lock adhesive · Screws of high quality steel 8 .8 or 10 .9 must be used to secure safe mounting of the LC3 to the application .Page 86 of 264
Cable connections overview 3-stage is used as examples but variants are also applicable for 2-stage . This overview shows all possible cable connections, but please notice that some variants are upon request .
Variant
Top plateDrawing no .:1002W9005
Side entryDrawing no .:1002W9005
T000
Connections T001
5: Motor
Connections T100
5: Motor
Including protective grounding cable
Connections T200
5: Motor 6: Minifit through
3: Minifit through
Connections
5: Motor 6: HB through
3: HB throughPage 87 of 264
T030
Connections T040
5: Motor 6: Mains through 1Female connection top entry, male connection side entry
3: Mains through 1 Female connection top entry, male connection side entry
Connections T101
5: Motor 6: Mains through 2Male connection top entry, female connection side entry
3: Mains through 2 Male connection top entry, female connection side entry
Connections
5: Motor 6: Minifit through
3: Minifit throughPage 88 of 264
Including protective grounding cable
T201
Connections T031
5: Motor 6: HB through
3: HB through
Including protective grounding cable
Connections T041
5: Motor 6: Mains through 1Female connection top entry, male connection side entry
3: Mains through 1 Female connection top entry, Including protective grounding cable male connection side entry
Connections
5: Motor 6: Mains through 2Male connection top entry, female connection side entry
3: Mains through 2 Male connection top entry, Including protective grounding cablefemale connection side entry
Page 89 of 264
T110
Connections T120
5: Motor 6: Minifit through (top) 7: Minifit through (top)
3: Minifit through (side) 4: Minifit through (side)
Connections T220
5: Motor 6: HB through 7: Minifit through
3: HB through 4: Minifit through
Connections
5: Motor 6: HB through (top) 7: HB through (top)
3: HB through (side) 4: HB through (side)
Page 90 of 264
T130
Connections T140
5: Motor 6: Mains through 1Female connection top entry, male connection side entry 7: Minifit through
3: Mains through 1 Female connection top entry, male connection side entry4: Minifit through
Connections T230
5: Motor 6: Mains through 2Male connection top entry, female connection side entry 7: Minifit through
3: Mains through 2 Male connection top entry, female connection side entry4: Minifit through
Connections
5: Motor
6: Mains through 1
3: Mains through 1
Female connection top entry,
Female connection top entry,
male connection side entry
male connection side entry
7: HB through
4: HB throughPage 91 of 264
T240
Connections S300
5: Motor 6: Mains through 2Male connection top entry, female connection side entry 7: HB through
3: Mains through 2 Male connection top entry, female connection side entry4: HB through
Connections S400
3: Motor supply
Connections
3: Motor supplyPage 92 of 264
S500
Connections S301Connections S401Connections
3: Motor supply
3: Motor supply
Including protective grounding cable
3: Motor supply
Including protective grounding cable
Page 93 of 264
S501Connections S310
3: Motor supply
Including protective grounding cable
Connections S320
6: Minifit through
3: Motor supply 4: Minifit through
Connections
6: HB through
3: Motor supply 4: HB through
Page 94 of 264
S410
Connections S420
6: Minifit through
3: Motor supply 4: Minifit through
Connections S510
6: HB through
3: Motor supply 4: HB through
Connections
6: Minifit through
3: Motor supply 4: Minifit through
Page 95 of 264
S520
Connections S330
6: HB through
3: Motor supply 4: HB through
Connections S340
6: Mains through 1 Female connection top entry, male connection side entry
3: Motor supply 4: Mains through 1Female connection top entry, male connection side entry
Connections
6: Mains through 2 Male connection top entry, female connection side entry
3: Motor supply 4: Mains through 2Male connection top entry, female connection side entry
Page 96 of 264
[xyz-ips snippet=”download-snippet”]