MASTECH Digital Clamp Transounducer User Manual

MS3300DIGITAL CLAMP TRANSDUCERUser’s Manual

Safety Information

The AC/DC current transducer has been designed according to lEC-61010 and IEC-61010-2-032 concerning safety requirements for electrical measuring instruments and hand-held current clamps with an overvoltage category (CAT II) and pollution 2.

Follow all introductions and operating requirements to insure that AC/DC current transducer is used safely and is kept in good operating condition.

  1. Symbols

    Important safety information, refer to the operating manual.

    Double insulation ( Protection classll)

    CAT II: MEASUREMENT CATEGORY II is applicable to test and measuring circuits connected directly to utilization points (socket outlets and similar points) of the low-voltage MAINS installation.

Description

Refer to the Figure 1. And to the following numbered steps to familiarize yourself with the AC/DC current transducer

1

Transformer JawsDesigned to pick up the ac. or dc current following through the conductor.

2

Hand GuardDesigned to protect user for safety.

3

TriggerPress the lever to open the transformer jaws.

4

DCA ZEROAdjusting the DCA ZERO knob, when the display is not zero reading for doesn’t measurement before.

5

Power On indication
6 Function SwitchSelect the ac or dc current.
7 Output Plugs

Specifications

Accuracy is specified for a period of one year after calibration and at 18°C to 28°C(64F to 82F) with relative humidity to 80. Accuracy specifications are given as: tof reading digits

  1. GeneralDC CURRENT RANGE: 1A dc to 1000A dc. AC CURRENT RANGE: 1A ac to 1000A ac. RMSOUTPUT VOLTAGE: 1 mV dc. per 1 Ado or 1A ac.WORKING VOLTAGE:1000V CAT II Per IEC-61010-1MAXIMUM ALTITUDE: 2000mOPERATING TEMPERATURE:0°C to 40°<C 80 relative humiditySTORAGE TEMPERATURE:-10°C to 50°C TEMPERATURE COEFFICIENT:0.2x(Spec Acc’y) /°C <18°C or>28°CMAXIMUM JAW OPENING: 55mmSIZE: 256x104x47WEIGHT: Approx. 520g
    This instrument must not be used on uninsulated conductors at a voltage greater than 250 ac rms. or 250 v de
  2. Electrical specification dc current DC Current
    Range Measure Output Accuracy
    1000A   1000mV ±3.0%±5

Overload Protection: 1200A for 60 seconds maximum.

AC Current

Range Measure Output Accuracy
A~ 1000A 1000mV 3.0%±5

Overload Protection:1200A for 60 seconds maximum.Frequency range: 50Hz to 60Hz.

Precaution and Preparations for Measurement

1 Dot not applies the voltage to the output plugs of AC/DC current transducer.
2 Do not use or store this instrument in a high temperature or high humidity environment and do not store the unit indirect sunlight.
3 Do not measure current before the AC/DC current transducer is not combined with DMM.

 

Using this appliance in an environment with a strong radiated radio-frequency electromagnetic field (approximately 3V/m) may influence its measuring accuracy. The measuring result can be strongly deviating from the actual value.

DC Current Measurement

1 Set the AC/DC current transducer function switch at desired A position.
2 Seta DMM at DCV function and a relevant range.
3 Connect the output plug of AC/DC current transducer with a DMM and combined firmly.
4 Adjusting the DCA ZERO knob until the DMM display show “0”, when does not measurement before.
5 Press the trigger to open transformer jaws and clamp one conductor only, making sure that the jaws are firmly closed around the conductor.
6 Read the reading on the LCD display of DMM along with the polarity of the red lead connection.

AC Current Measurement

1 Set the AC/DC current transducer function switch at desired A~ position.
2 Set a DMM at DCV function and a relevant range.
3 Connect the output plug of AC/DC current transducer with a DMM and combined firmly
4 Press the trigger to open transformer jaws and clamp one conductor only, making sure that the jaws are firmly closed around the condu
5 Read the reading from the digital display of the DMM.

Maintenance

To keep the instrument clean, wipe the case with a damp cloth and detergent, do not use abrasives or solvents. Any adjustment,  maintenance and repair shall be conducted by service personnel.

Accessories

  • Operator’s instruction manual
  • Gift box
  • 9 volt battery. NEDA 1604 6F22 OO6P type

Replacing The Batteries

WARNINGTo avoid electric shock, make sure that the test leads have been clearly move away from the circuit under measurement before opening the battery cover of the meter.

  1. Ifthe sign  appears, it means that the batteries should be replaced.
  2. Loosen the fixing screw of the battery cover and remove it.
  3. Replace the exhausted batteries with new ones.
  4. Put the battery cover back and fix it again to its origin form.Note:Do not reverse the polarity of the batteries.