MAYUR Wired + Wireless Grey Protector Ultra GSM Alarm System, 400mtr To 500mtr User Manual

MAYUR Wired + Wireless Grey Protector Ultra GSM Alarm System, 400mtr To 500mtr

SYSTEM INTRODUCTION

This Product is a GSM security alarm system, Inbuilt with advance GSM digital signal processing technology and wireless intelligent control function. It is highly integrated with remote control and SMS recognition. We get SMS at every status of the system.It can connect with PIR, door contacts, Shutter sensor emergency switch.Wired and wireless systems widely used in houses, Banks, shops, stores, villas, etc.

FEATURES

  • Intelligent 2 Zone Hybrid (Wired and wireless)Control Panel with GSM Auto Dialer
  • One wired Zone with Programmable Delay and second 24Hrs Emergency zone.
  • ARM/ DISARM through RF Remote, text SMS & Mobile APP.
  • Wired/Wireless Door/Shutter/ PIR/ Vibration/Smoke Can be Program
  • Total 24 Nos. Wireless remote and sensors can be program.
  • LED indications for Zone, ARM, Network, Power & System status
  • Programmable Entry, Exit & Siren time
  • Auto dials 5 Tel / Mobile Numbers
  • Auto alert by SMS on 5 Mobile Numbers
  • Tel/Mobile Number can be program by SMS/ Mobile APP.
  • SMS alert facility can monitor panel status.
  • Automatic rearming after power resumes.
  • Built in battery backup provision (upto7Ah)
  • Rigid MS powder coated body

CONTROL BOARD CONNECTIONS

PROGRAMMING OF WIRELESS REMOTE AND SENSORS

a) How to Add Wireless Remote/Sensors:

  1. Wireless Remote: Press wireless Remote/Sensor Add and Delete switch “Red LED” will turn ON then press any key on wireless remote. Remote will add successfully.
  2. Wireless Door Sensor: Place Wireless Door Sensor and Magnet together then Press wireless Remote/Sensor Add and Delete switch “Red LED” will turn ON. After that remove magnet from Wireless Door sensor. Wireless Door Sensor will add successfully.
  3. Wireless PIR Motion Sensor: Press wireless Remote/Sensor Add and Delete switch “Red LED” will turn ON then do motion in front of wireless motion sensor. Wireless Motion Sensor will add successfully.

b) How to Delete Wireless Remote/Sensors:

Long Press wireless Remote/Sensor Add and Delete switch “Red LED” will turn ON for 10sec then it will turn OFF. All Wireless Remote and Sensors will delete successfully.

PROGRAMMING DETAILS

DEFAULT FACTORY SETTINGS
1 Entry delay time 30 sec
2 Exit delay time 30 sec
3 Siren output ON for all zone 10 min
4 Chime Enable
5 Master code 2580
6 Confirmation beep 1 beeps

Note:

  1. If battery voltage is less than 9V then panel will accept only “DISARM” command through remote.
  2. JIO SIM card is not supported to our system.

PROGRAMMING BY SMS

ALL PROGRAM IN DISARM MODE
  1. TO CHAECK NETWORK IS AVAILABLE:– Insert SIM card in the system, to check network call on desired SIM card, if Ringing Network is OK, SIM is ready for system, if Network is not OK check/change SIMCARD.
  2. TO CHANGE ENTRY DELAY:-Go to SMS, type SMS as 25804SSS (Set SSS sec entry delay as 005 to 999 seconds), send to control panel. – Panel gives confirmation beep and receives SMS as “Entry delay changed successfully”
  3. TO CHANGE EXIT DELAY:-Go to SMS, type SMS as 25806SSS (Set SSS sec exit delay as 001 to 999 seconds), send to control panel. – Panel gives confirmation beep receive SMS as “Exit delay changed successfully “
  4. TO CHANGE SIREN TIME:-Go to SMS, type SMS as 25807MM (Set MM min siren time as 01 to 99 minutes), send to desired SIM card through mobile – getting one confirmation beep and received SMS as “Siren time changed successfully”
  5. ZONE BYPASS: (ZONE1/ZONE2/TAMPER)-ZONE1:Go to SMS, type SMS as 2580810 (Zone1 Bypass Disable), 2580811 (Zone1 Bypass Enable), send to control panel.–ZONE2: Go to SMS, type SMS as 2580820 (Zone2 Bypass Disable), 2580821 (Zone2 Bypass Enable), send to control panel.-TAMPER: Go to SMS, type SMS as 2580830 (Tamper Bypass Disable), 2580831 (Tamper Bypass Enable), send to control panel.
  6. CHIME (OPEN Indication) ENABLE/DISABLE: -Go to SMS, type SMS as 258090 (Chime Disable), 258091 (Chime Enable), send to control panel. – Receive SMS as “Chime Enabled/Disabled”
  7. ARM DISARM SIREN NOTIFICATION:-Go to SMS, type SMS as 258096 (SIREN ARM DISARM beep Enable), 258097 (SIREN ARM DISARM beep Disable), send to control panel. – Receive SMS as “ARM AND DISARM Enabled/Disabled.
  8. TO CHANGE MASTER CODE:– Type SMS from your mobile 2580000XXXX (Set XXXX new password), send to control panel. – Panel gives confirmation beep and receives SMS as “password saved successfully “.
  9. TO REGISTER (STORE) MOBILE NUMBERS FOR CALL:NOTE: XXXX is your master code. e.g. 2580

    FUNCTIONS

    MASTER CODE SR. NO. OF MOBILE MOBILE NUMBER
    To Store 1st Number XXXX 101

    MOBILE NO.

    To Store 2nd Number

    XXXX 102 MOBILE NO.
    To Store 3rd Number XXXX 103

    MOBILE NO.

    To Store 4th Number

    XXXX 104 MOBILE NO.
    To Store 5th Number XXXX 105

    e.g. If 2580 is MASTER CODE then type SMS 2580101991234567825801029987654321NOTE: After store the number panel gives one confirmation beep and receive message as voice numbers saved successfully

  10. TO REGISTER (STORE) MOBILE NUMBERS FOR MESSAGE (SMS):

    FUNCTIONS

    MASTER CODE SR. NO. OF MOBILE MOBILE NUMBER
    To Store 1st Number XXXX 121

    MOBILE NO.

    To Store 2nd Number

    XXXX 122 MOBILE NO.
    To Store 3rd Number XXXX 123

    MOBILE NO.

    To Store 4th Number

    XXXX 124 MOBILE NO.
    To Store 5th Number XXXX 125

    MOBILE NO.

    e.g. If 2580 is MASTER CODE then type SMS 2580121991234567825801229987654321

NOTE: After store the numbers panel gives one confirmation beep and receive message as SMS numbers saved successfully.

OPERATIONS BY SMS:

OPERATIONS

SMS SEND TO PANEL

RESPONSE

DISARMING BY SMS

XXXX0 SYSTEM DISARMED
ARMING BY SMS XXXX1

SYSTEM ARM

PANIC BY SMS

XXXX2 TRIGGERED BY PANIC SMS
STATUS BY SMS XXXX3

CURRENT STATUS OF SYSTEM

REMOTE OPERATION

To “DISARM” the system.
To “ARM” the system.
Reserved for future use.
“PANIC” alarm switch.

Note: 1) If any zone is violated then particular zone violation message is received.

This procedure can bound mobile phone APP and alarm system. Protecor Ultra Alarm System mobile APP can add multi accounts that are one mobile phone control multi Protector Ultra Alarm Systems.

To add host accounts: Click Mayur Security Simplified software to enter [User List] interface. Click icon to enter New User Registration interface[Fig. 1], then input host number and account name and password twice, click [ SUBMIT ] to finish registration [Fig. 2]. The host number is the SIM card number in host, and user can define account name, the password is host administrator password.

     

After adding host account, it will display account name and host number on main page [Fig. 3], then click account name to enter function interface [Fig.4].Move to the left [Menu] to enter General set interface and system set interface.      

To set voice numbers in system click on voice No. 1 enter 10 digit mobile number or telephone number and click on [ SET ] button. Host will give confirmation beep after receiving the message, and reply message to mobile phone automatically, which means the “Voice number saved successfully”.[Fig.6].

To set SMS numbers in system click on SMS No. 1 enter 10 digit mobile number and click on [SET] button. Host will give confirmation beep after receiving the message, and reply message to mobile phone automatically, which means the “SMS number saved successfully”.[ Fig.7 ].   

SPECIFICATIONS

Mains Supply Voltage 230V AC, 50Hz +/-10%
Battery (Provision) 7Ah 12V, SMF, Rechargeable.
Battery Recharge Voltage 13.8V, +/-0.2V DC
Stand-By Current: 100 ~ 350 mA
Operating Temperature: 0 – 45 Degrees Celsius
Dimensions: 240mm x 180mm x 80mm
Cabinet: MS, Powder Coated
Weight: 2 Kg

WARRANTY

PROTECTOR ULTRA alarm system is warranted against all manufacturing defects for a period of 24 months from the date of purchase (In case of any complaints please contact your dealer). Warranty is not applicable to rubber / plastic parts, battery, chipping / peeling of paint, coating and any other damage due to mishandling & negligence, normal wear and tear and tampering by unauthorized person OR in case the serial number is altered / defaced OR tampered with, other conditions subject to the above, the unit should be brought to the nearest Dealer OR our Factory at your cost along with the Warranty Card issued by the dealer with his seal and signature.

LIABILITY FOR CONSEQUENTIAL LOSS OR DAMAGE IS NEITHER ACCEPTED NOR IMPLIED.

LIMITED WARRANTY: Seller does not represent that the product may not be compromised or circumvented; that the product will prevent any personal injury or property loss or burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly install LED and maintained alarm may only reduce the risk of a Burglary, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result.

Consequently, Seller shall have no liability for any personal injury, property damage or other loss based on a claim the product failed to give warning. However, if Seller is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or Origin, Seller’s maximum liability shall not in any case exceed the purchase price of the product, while shall be the complete and exclusive remedy against Seller.

We reserve the rights to modify “The Design & Specifications” of the products without prior notice.

Date of Purchase: Dealer’s Sign & Seal
Bill No. :
Serial No. :

Mfg by: MAYUR MICRO TECHNIQUES (I) PVT LTD. PUNEHelpline: 020 27230063, +91 8605011992/93

report this ad