milwaukee L4CLL Rechargeable Green Cross Line Laser Level Instructions

L4CLL Rechargeable Green Cross Line Laser Level

GB Original instructions

1

L4 CLL, L4 CLLP

CONTENTSImportant safety instructions………………………………………………………………………………………….1 Maintenance ……………………………………………………………………………………………………………….2 Technical data……………………………………………………………………………………………………………..2 Specific conditions of use ……………………………………………………………………………………………..2 Overview…………………………………………………………………………………………………………………….3 Accessory …………………………………………………………………………………………………………………..4 Replace batteries…………………………………………………………………………………………………………4 Fuel gauge………………………………………………………………………………………………………………….5 Low battery indication…………………………………………………………………………………………………..5 Charge ……………………………………………………………………………………………………………………….5 Magnetic wall mount…………………………………………………………………………………………………….6 Riser ………………………………………………………………………………………………………………………….7 Track clip ……………………………………………………………………………………………………………………7 Working in self-leveling mode………………………………………………………………………………………..8 Working in manual mode ………………………………………………………………………………………………9 Plumb function…………………………………………………………………………………………………………..10 Detector ……………………………………………………………………………………………………………………10 Accuracy check …………………………………………………………………………………………………………11IMPORTANT SAFETY INSTRUCTIONSCAUTION! WARNING! DANGER! Do not use the product before you have studied the safety instructions and the user manual. Laser ClassificationLaser Beam outlet aperture WARNING: It is a Class 2 laser product in accordance with EN60825-1:2014 .LASER 2ENGLISH

WARNING: Avoid direct eye exposure. The laser beam can cause severe eye damage and/or blindness. Do not stare into the laser beam or direct it towards other people unnecessarily. Caution! The laser emitting product may be behind you in some applications. Be careful when facing the product. WARNING: Do not operate the laser around children or allow children to operate the laser. The reflective surface could reflect the beam back at the operator or other persons. WARNING: Use of controls, adjustments, or the performance of procedures other than those specified in the manual may result in hazardous radiation exposure. When the laser is brought into a warm environment from very cold conditions, or vice versa, allow it to come to the surrounding temperature before use. Always store the cross laser indoors, avoid substantial knocks, continuous vibration or extreme temperatures. Always keep the tool away from dust, liquids and high humidity. These may damage internal components or affect accuracy. If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam. Do not position the laser beam so that it unintentionally blinds you or others. Do not look into a laser beam using magnifying optical devices such as binoculars or a telescope, as this will increase the level of eye injury. If you use laser goggles to enhance the visibility of the laser beam, please notice that they will not protect your eyes against laser radiation. Do not remove or deface warning labels on the laser level. Do not disassemble the laser level, laser radiation can cause serious eye injury. When not in use, turn off the power, engage the pendulum lock and place the laser in its carrying pouch. Make sure the pendulum lock mechanism is engaged before transporting the laser. Note: If the pendulum lock mechanism is not engaged before transportation, internal mechanical damage may occur. Do not use aggressive cleaning agents or solutions. Use only a clean, soft cloth for cleaning. Avoid heavy impact to or dropping of the laser. The accuracy of the laser should be checked before use if it has been dropped or subjected to other mechanical stresses. Any repair required on this laser product should be performed only by authorised service personnel. Do not operate the product in explosion hazardous areas or in aggressive environments. If the laser level is not in use for a long period of time, remove the batteries from the battery compartment. This will prevent batteries from leaking and corrosion damage.Flat batteries must not be disposed of with household waste. Care for the environment and take them to the collection points provided in accordance with national or local regulations. The laser must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regulations in force in your country. Adhere to the national and country specific regulations. Please contact your local authority or your dealer for how to dispose of batteries properly.European Conformity MarkBritish Conformity Mark1

MAINTENANCEWipe the aperture lens and the body of the cross laser with a clean soft cloth. Do not use solvents.Although the cross laser is dust and dirt resistant to a certain degree, do not store in dusty places as long term exposure may damage internal moving parts.If the cross laser is exposed to water, dry the laser level before returning it to the carrying case to prevent corrosion damage.

TECHNICAL DATA

Laser Class

2

Self-Leveling Range

± 4°

Self-Leveling Time

3s

Battery technology

Li-Ion

Voltage DC

4 V

USB input

5 V DC; 2.1 A max.

DC output

4 V 2.1 A

AC/DC Adaptor Input

100-240 V ~ 50/60 Hz; 0.6 A max.

AC/DC Adaptor Ouput

5 V 2.1 A; 10.5 W

Charging time

130 min

Power input

1,5 W @ 4.2 V

Protection class (water and dust protection)

IP54

Max. altitude

2000 m

Relativ air humidity max.

80%

Pollution degree according to

2*

IEC 61010-1

Pulse duration tP Functions

70 s

L4 CLL horizontal, vertical, cross line

L4 CLLP horizontal, vertical, cross line, plumb function (2 points)

Frequency

10 kHz

Projections

2 lines green, 2 points green

Diode Quantity

2

Diode type

30 mW

Laser beams output pattern

L4 CLL Single horizontal, single vertical, cross line

L4 CLLP Single horizontal, single vertical + 2 plump dots up and down , cross line + 2 plumb dots (up and down).

Operating time

8 hrs

Tripod mount

1/4″ thread

ENGLISH

Suitable detector

Milwaukee LLD50

Laser Line

Width < 9.53mm @ 30m

Wavelength 510 – 530 nm Laser Class II

Max. Power 7 mW

Accuracy +/- 3 mm / 10 m

Fan angle Vertical Line > 120°; Horizontal Line > 120°

Colour green

Working Range 30 m (with detector 50 m)

Laser plumb (L4 CLLP only)

Laser point wavelength 510 – 530 nm Laser Class II

Laser point max. power < 1 mW

Plumb accuracy +/- 3 mm / 10 m

Laser point colour green

Working Range 30 m

Recommended ambient operating temperature

-10°C – +40 °C

Storage Temperature

-20°C – +60 °C

Recommended ambient charging temperature

5°C – +60 °C

Recommended battery types

L4B3

Recommended USB Power Supply CUSB

Dimensions

135 mm x 61 mm x 97 mm

Weight (incl. Battery)

L4 CLL 995 g

L4 CLLP 998 g

* Only non-conductive deposits occur, wherby occasional temporary conductivity caused by condensation is expected.SPECIFIC CONDITIONS OF USEThe product is designed for mainly indoor use. For outdoor use make sure that the boundary conditions are the same as for indoor use. The laser is innovatively designed for a very broad range of professional jobs, including: – Aligning tiles, marble, cabinets, borders, moldings and trimmings – Marking layout for doors, windows, rails, stairs, fences, gates, decks and pergolas installation. – Transferring reference point for light installations, vents, transfer of heights, levelling perimeterwalls, wall studs, setting out tracks on floors and all other professional use. – It is intended for determining and checking horizontal and vertical lines. Do not use this product in any other way as stated for normal use.

2

OVERVIEWPlumb spot up (only L4 CLLP) Vertical laser beam window Horizontal laser beam window Rotation dialOff / locked On / manual mode On / self leveling modeBatteryMagnetic mountUSB port LED indicator – Fuel gauge – Charging status 360° AdjustmentPlumb spot down (only L4 CLLP) 1/4″ tripod mountENGLISH

Beam selector LED indicator horizontal vertical cross lineMode button Short press: choose between beams: – horizontal – vertical + plumb function – cross lines + plumb function Long press: low power mode LED indicator – Fuel gauge – Charging statusRiser (only L4 CLLP)Track clip3

ACCESSORYAccessory – Not included in standard equipment, available as an accessory. Clamp LM360Hi-Vis target HI-VIST Detector LLD50

REPLACE BATTERIESOnly use Milwaukee Type L4B3 rechargeable batteries.1

2

Milwaukee L4B3

Tripod TRP180

3

ENGLISH

4

FUEL GAUGEAfter switch on or switch off the laser the fuel gauge will display the battery life for 3 seconds

Green solid Yellow solid Red solid Red flashing

100% – 50% remaining 49% – 11% remaining 10% – 3% remaining 3% – 0% remaining

CHARGEIt is possible to work with the laser during charge.

1

2

3DC 5 V 0,1 – 2,1 A

Red breathing Yellow breathing Green solid Red/Green flashing Red breathing Green flashing

Charging, 0-49% charged Charging, 50-99% charged 100% charged No battery, damaged battery, faulty battery, over temperatur Charging during use No battery inserted during use

LOW BATTERY INDICATIONWhen the voltage is low, the laser switch to power safe mode. The laser will blink in self leveling mode

4 sec.

1 sec.

The laser will blink in manual mode

8 sec.

1 sec.

From now on it is still possible to continue the work.When the voltage is too low, the laser and the LED will flash 3 times and it automatically shuts down.

ENGLISH

5

MAGNETIC WALL MOUNTUse the magnetic wall mount to fix the laser to a wall or metallic structures or similar. Turn the laser 360° with fine adjustment.

Tripod mount 1/4″

ENGLISH

6

RISERUse the riser to come over the floor track

TRACK CLIPUse the track clip to clamp the laser to ceiling channels, racks….

ENGLISH

7

WORKING IN SELF-LEVELING MODEIn self-leveling mode the cross laser will level itself in a ± 4° range and can project a horizontal beam, a vertical beam or both beams simultaneously + plumb dot up and down (plumb dot only L4 CLLP).1

Place the cross laser on a solid flat vibration free surface or on a tripod.

1/4″ male thread

2Turn the rotation dial to: .

4Choose the beams that you want to work with by pushing the MODE button.

3

The cross laser will generate

C

2 laser beams.

(A) horizontal beam forward (B) vertical beam forward (C) Laser point

B D

(D) The cross laser will generate

A

forward cross beam when all

beams are activated.

5If the initial level of the cross laser is beyond ±4° and the self-leveling mode is activated, the laser beams will flash.In this case reposition the cross laser.

> 4° > 4°

ENGLISH

6

Before moving the cross laser, turn the

C

rotation dial to: .

This will lock the pendulum and protect your cross laser.

8

WORKING IN MANUAL MODEIn manual mode the cross lasers self-leveling mechanism is disabled and the laser lines can be set at any slope required.1Place the cross laser on a solid flat vibration free surface or on a tripod.2Turn the rotation dial to:3Same as in the self-leveling mode, the cross laser will generate 2 laser beams, but the laser beams are interrupted every 8 seconds.8 sec. 8 sec. 8 sec.

4Choose the beams that you want to work with by pushing the MODE button.5Tilt the laser and adjust to the desired angle and height.

ENGLISH

6 To turn the Manual mode off,turn the rotation dial to: . or turn the rotation dial to: .9

PLUMB FUNCTIONWith the plumb function, a point on the floor and on the ceiling can be projected. Use the plumb function e.g. to transfer reference point for light installation, vents, transfer of heights.

DETECTORFor outdoor work under direct sunlight, or bright conditions and for extended indoor ranges of up to 50 meters / 164 feet, use the Milwaukee detector.A detector is not included and must be purchased separately.For information on how to operate the detector, please refer to the operating instructions for the detector.

ENGLISH

10

ACCURACY CHECKThis cross laser left the factory fully calibrated. Milwaukee recommends the user to check the accuracy of the laser periodically, especially if the unit falls or is mishandled.If the maximum deviation of the laser is exceeded in one of the accuracy checks,please contact one of our Milwaukee service agents (see our list of guarantee/service addresses).1. Checking the height accuracy of the horizontal beam. 2. Checking the leveling accuracy of the horizontal beam. 3. Checking the leveling accuracy of the vertical beam. 4. Checking the plumb accuracy.Before checking the laser accuracy, after mounting the laser on the tripod, check the leveling of the tripod.

5. Turn the laser 180° towards wall B and mark the center of the cross beams as b1 on the wall.180° b1a1

1 CHECKING THE HEIGHT ACCURACY OF THE HORIZONTAL BEAM (UP AND DOWN DEVIATION)1. Set up the laser on a tripod or on a flat surface between two walls A and B, approximately 5 meters apart.2. Position the laser level approximately 0.5 meter from wall A. 3. Switch ON the self-leveling mode and press the button to project the horizontal and thevertical cross beams towards wall A. 4. Mark the center of the cross beams on the wall as a1.

A

§P

B

a1

6. Move the laser level towards wall B and position it approximately 0.5 meter from wall B. 7. Mark on wall B the center of the cross beams as b2.

A

B

b2

a1

b1

P8. Turn the laser 180° towards wall A, and mark on the wall the center of the cross beams as a2.

A

B

180°

a2

b2

a1

b1

PENGLISH

9. Measure the distances: a= |a2-a1| b= |b1-b2|10.The difference | a ­ b| should be no more than 2 mm.11

2 CHECKING THE LEVEL ACCURACY OF THE HORIZONTAL BEAM (SIDE TO SIDE INCLINATION)

For this check, a free surface of approx. 5 x 5 meters is required.1. Set up the laser on a tripod or on a solid surface between two walls A and B, approximately 5 meters apart.2. Position the laser level approximately 2.5 meters from the center of the room.3. Switch ON the self-leveling mode and press the button to project the horizontal line towards wall A and B.4. Mark the center of the laser line point a1 on wall A and point b1 on wall B.

5. Move the laser level approximately 5 meters away and turn the laser 180° towards wall A and B.6. Mark the center of the laser line point a2 on wall A and point b2 on wall B.A

Aa1

a1 a2B

Bb1 b2

b1

7. Measure the distances: a= |a2- a1| b= |b1- b2|8. The difference | a ­ b| should be no more than 2 mm.

ENGLISH

12

3 CHECKING THE LEVEL ACCURACY OF THE VERTICAL BEAM1. Hang an approximately 4 m plumb line on a wall.2. After the plumb line has settled, mark point a1 on the wall, behind the plumb line, near the plumb cone.a1

4 CHECKING PLUMB ACCURACY

This procedure requires a room of with approx. 5m distance between floor and ceiling.1. Set up the cross laser on a tripod.2. Switch ON the self-leveling mode and press the push button to switch to the plump function.3. Mark the upper plumb dot on the ceiling as point a1 (see the illustration).4. Mark the lower plumb dot on the floor as point b.

a1 Pb

3. Set up the cross laser on a tripod or on a flat surface in front of the wall at a distance of approximately 2 m.4. Switch ON the self-leveling mode, and press the button to project the vertical beam towards the plumb line.5. Turn the cross laser so that the vertical beam will merge with the plumb line below the hanging point.6. Mark point a2 on the wall, in the middle of the vertical beam at the same height as a1.7. The distance between a1 and a2, should be no more than 1 mm.ENGLISH

a2 a1 P

5. Rotate the laser level 180°, position it so that the center of the plumb dot is on the point b, which has already been marked, and allow it to level.6. Mark the center of the upper plumb dot on the ceiling as point a2.7. The distance between points a1 and a2 marked on the ceiling is an indication of the actual deviation of the laser level from the ideal plumb line. If the measuring distance is 5m, the maximum permissible deviation is:5m x (+/- 0.6mm/m) x 2 = +/ – 6mm.8. The distance between a1 and a2, should not be more than 6 mm.

a1

a2

180°

b

13

Copyright 2021Techtronic Industries GmbH Max-Eyth-Str. 10 71364 Winnenden Germany+49 (0) 7195-12-0www.milwaukeetool.eu

Techtronic Industries (UK) Ltd Fieldhouse Lane Marlow Bucks SL7 1HZ UK

(01.21)4100 4704 47

References

[xyz-ips snippet=”download-snippet”]