motorola Multi-Unit Charger Kits PMPN4156 User Guide

MULTI-UNIT CHARGER KITSPMPN4156QUICK START GUIDE

IMPORTANT SAFETY INSTRUCTIONS

This document contains important safety and operating instructions. Please read these instructions carefully and save them for future reference.Before using the battery charger, read all the instructions and cautionary markings on (1) the charger, (2) the battery, and (3) the radio using the battery.WARNING

  1. To reduce the risk of damage to the power cords, pull the plug rather than the cord when disconnecting from the AC outlet or the charger.
  2. An extension cord should not be used unless absolutely necessary. The use of an improper extension cord could result in a risk of fire and electric shock. If an extension cord must be used, make sure that the cord size is 18 AWG for lengths of up to 6.5 feet (2.0 m), and 16 AWG for lengths up to 9.8 feet (3.0 m).
  3. To reduce the risk of fire, electric shock, or injury, do not operate the charger if it has been broken or damaged in any way. Take it to a qualified Motorola Solutions service representative.
  4. Do not disassemble the charger. It is not repairable and replacement parts are not available. Disassembly of the charger may result in a risk of electric shock or fire.
  5. To reduce the risk of electric shock, unplug the charger power cord from the AC outlet before attempting any maintenance or cleaning.
  6. To reduce the risk of injury, charge only the rechargeable Motorola Solutions authorized batteries listed in Table 3. Other batteries may explode, causing personal injury and damage.
  7. Use of accessories not recommended by Motorola Solutions may result in a risk of fire, electric shock, or injury.

OPERATIONAL SAFETY GUIDELINES

  • This equipment is not suitable for outdoor use. Use only in dry locations and conditions.
  • Maximum ambient temperature around the charger must not exceed 40 °C (104 °F).
  • The radio can be turned ON only when it is transmitting data wirelessly, such as using Wi-Fi. Otherwise, turn OFF the radio.
  • Connect the charger to the power supply listed in Table 4 with an appropriate power cord listed in Table 5.
  • The AC outlet to which the power cord is connected should be close and easily accessible.
  • Make sure the power cord is located where it will not be stepped on, tripped over, or subjected to water, damage, or stress.
  • Connect the power cord only to an appropriately fused and wired AC outlet with the correct voltage, as specified on the product.
  • Disconnect from line voltage by removing the power cord from the AC outlet.
  • The Multi-Unit Charger charges the batteries listed in Table 3 when used with Pockets in Table 2. The batteries may be attached to the radio or maybe stand-alone.

Table 1: Multi-Unit Charger

Part Number

Description

PMPN4156_ MTP6000/MTP3000 Series Multi-Unit Charger

Table 2: Multi-Unit Charger Pockets (compatible with Charger(s) in Table 1)

Part Number

Description

AS000060A01 Insert Radio IMPRES 2 Device Program iTM Charger Tri-Unit
AS000061A01 Insert Radio Battery IMPRES 2 Device Program iTM Charger Tri-Unit

Table 3: Motorola Solutions Authorized Batteries

Part Number

Description

NNTN8020 Li-Ion Battery 1700 mAh
NNTN8023 Li-Ion Battery 2200 mAh
PMNN4522 IMPRES 2TM Li-Ion Battery 3400 mAh
PMNN4801_ IMPRES 2 Li-Ion Battery IP68 1900T
PMNN4802_ IMPRES 2 Li-Ion Battery IP68 3400T
PMNN4582_ IMPRES 2 Li-Ion Battery IP68 2900T

Table 4: Motorola Solutions Authorized Power Supply

Part Number

Description

PS000212A01 External 201 W Power Supply

Table 5: Motorola Solutions Authorized Power Cords

Part Number

Description

3087791G01 Power Cord, the United States / North America
3087791G04 Power Cord, Europe
3087791G07 Power Cord, United Kingdom / Hong Kong
3087791G10 Power Cord, Australia / New Zealand
3087791G13 Power Cord, Argentina
3087791G16 Power Cord, Korea
3087791G20 Power Cord, Japan
3087791G22 Power Cord, Brazil
CB000199A01 Power Cord, China

CHARGER OVERVIEW

Table 6: Charger Overview and Description

Number

Description

1-6 Front Row Pockets — To charge batteries attached to radio or stand-alone.
7-12 Back Row Pockets — To charge batteries attached to a radio.
13 Display — For Pocket 1 only. Displays the available menu selections.
14 Keypad — For menu selection.
15 LED Status Indicator — Available on all Front Row Pockets.
16 Communications Interface — Supports charger reprogramming and data upload to an IMPRESTM Battery Fleet Management System and iTM communication through a USB hub.
17 Power Connector Inlet — Compatible with Power Supply in Table 4.

OPERATING INSTRUCTIONS

  • Batteries charge best at room temperature.
  • Batteries to be attached to radio or stand-alone.
CHARGING PROCEDURE

  1. Place the Multi-Unit Charger (MUC) on a flat surface.
  2. Firmly insert the power supply into the charger DC Inlet Socket at the back of the charger.
  3. Plug the power supply power cord into a matching power outlet.
  4. Upon successful power-up, each pocket LED shows Green for one second and IMPRES 2 CHARGER is displayed. If the LEDs do not flash and no message is displayed, check power cord connections.
  5. Insert the radio with battery or stand-alone battery into an available pocket.
  6. When the radio or stand-alone battery is properly seated in the pocket:– Charging status of the radio is indicated by the LED Status Indicator and/or display of the radio.– Charging status of a stand-alone battery is indicated by the LED Status Indicator of the associated pocket on the MUC.– The Display of the MUC shows the charging status of Pocket 1 only.
  7. The radio or stand-alone battery is ready for use when the LED is Steady Green.
  8. You can only turn the radio on while charging when the Communications Module is detached from the charger. Otherwise, turn off the radio.

Note: Grip the radio body when inserting or removing the radio from the charger.Avoid pulling the radio antenna when removing the radio.

DISPLAY MESSAGES AND LED INDICATIONS

Table 7: Messages and LED Indications for IMPRES 2™ or IMPRES Battery

Status

Charger Display

LED Indication

Charger Powers On

IMPRES 2 CHARGER

Green for approximately one second.
Battery Detected

IMPRES 2 BATTERY or IMPRES BATTERY

The battery does not require Calibration:  Steady RedBattery requires Calibration but Calibration is disabled in charger: Alternating Amber and Green for four seconds.
Requesting IMPRES Battery Calibration (Calibration is disabled in charger)

  • Press OK to enable Calibration
  • Ignore for normal charging (message disappears after one minute)

ENABLE BATTERY CALIBRATION?

Steady Red
Battery Discharging

CAL DISCHARGExxxx0mAh yyy%

Steady Amber
Rapid Charging

RAPID CHARGE xxxx0mAh yyy%

Steady Red
Charged to 90% or more

TRICKLE CHARGExxxx0mAh    yyy%

 Flashing Green
Charged to 95% or more

CHARGE COMPLETE xxxx0mAh    yyy%

The battery does not require Calibration:  Steady GreenThe battery requires Calibration but Calibration is disabled in the charger: Alternating Amber and Green for four seconds then,  Steady Green. The battery may be nearing End of Service (battery is usable): Alternating Red and Green
Fault

NOT CHARGEABLE REMOVE& REINSERT

Flashing Red
Standby (Battery is waiting to rapid charge)

HOT BATTERY WAITING TO CHARGE or COLD BATTERYWAITING TO CHARGE orVERY LOW BATTERY WAITING TO CHARGE

Flashing Amber

Table 8: Messages and LED Indications for Other Motorola Solutions Batteries

Status

Charger Display

LED Indication

Charger Powers On

IMPRES 2CHARGER

Green for approximately one second.
Battery Detected

MOTOROLABATTERY

Steady Red
Rapid Charging

RAPID CHARGE xxxx0mAh    yyy%

Steady Red
Charged to 90% or more

TRICKLE CHARGE xxxx0mAh    yyy%

Flashing Green
Charged to 95% or more

CHARGE COMPLETE xxxx0mAh    yyy%

Steady Green
Fault

NOT CHARGEABLE REMOVE& REINSERT

 Flashing Red
Standby (Battery is waiting to rapid charge)

HOT BATTERY WAITING TO CHARGE orCOLD BATTERYWAITING TO CHRGEorVERY LOW BATTERYWAITING TO CHARGE

Flashing Amber

PROGRAMMING A RADIO WITH ITM PROXYNote: Contact your local dealer to order the programming cable (Part Number: CB000458A07).

OPTIONAL EQUIPMENT

A wall mount bracket (Part Number BR000270A01) is available for the Multi-Unit Charger (MUC). Contact your local dealer to order this item. Installation of the wall mount bracket is as follows:

WARNING

  • This wall mount bracket should be installed by a trained and experienced technician. Having the product installed by a nonspecialized technician is very dangerous, and can cause damage or injury.
  • Do not install the product where the weight cannot be supported. If the strength of the location where the wall mount is installed is not strong enough, it can fall off and cause an injury.
  • Do not install on a structure that is prone to vibration, movement, or chance of impact.

Figure 3: Mounting Multi-Unit Charger to Wall Bracket

  1. Position the wall mount bracket in the desired position, and mark the location of the mounting holes on the wall surface.CautionEnsure the area behind the mounting surface is always free of electrical wires, cables, and pipes before cutting, drilling, or installing the mounting screws.
  2. Mount bracket to the wall using the appropriate mounting hardware required for the type of wall material fixture it is being mounted to. Drill based on the marked mounting holes on the wall surfaces.
  3. Secure the wall bracket in position by installing mounting hardware over the mounting holes on the wall bracket tightly.Note: It is recommended to use 10-16×1-1/2” tapping screw and washer (not included) on wood stud and solid-flat concrete/brick wall.
  4. Hang the MUC on the wall bracket as shown in Figure 3.

ADDITIONAL FEATURES AND INFORMATION

The complete online user guide is available through publication part number MN003509A01 at https://businessonline.motorolasolutions.com. This guide provides information on features of the Multi-Unit Charger, including:

  • IMPRES 2 Charging Features
  • Details regarding charging status and LED indications for various batteries
  • Charger Reprogramming
  • IMPRES Battery Fleet Management
  • Charger Setup Options– Preparing Lithium-ion Batteries for Shipment– Long-Term Battery Storage– Enabling or Disabling Calibration/Reconditioning– IMPRES Battery End-of-Service Life Indication Selection– Display Format Selection– Power Saver Selection
  • Battery Analyzer Mode

MOTOROLA, MOTO, MOTOROLA SOLUTIONS, and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC and are used under license.All other trademarks are the property of their respective owners.© 2017 and 2021 Motorola Solutions, Inc. All rights reserved.

Motorola Solutions Malaysia Sdn. Bhd. (Co. No. 455657-H)Plot 2A, Medan Bayan LepasMukim 12, S.W.D.11900 Bayan Lepas, Penang.MalaysiaEU Contact:Motorola Solutions, Czerwone Maki 82,30-392 Krakow, Polandhttps://businessonline.motorolasolutions.com

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by