NOD U-650 Line Interactive UPS User Manual

NOD U-650 Line Interactive UPS

Thank you for choosing our product. We hope you will enjoy using the appliance.

SYMBOLS IN THESE INSTRUCTIONS FOR USE

Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid accidents and prevent damage to the machine:

Warning:

This warns you of dangers to your health and indicates possible injury risks.

Caution:

This refers to possible hazards to the machine or other objects.

Note:

This highlights tips and information.

GENERAL NOTES

Read the operating instructions carefully before putting the appliance into operation and keep the instructions including the receipt and, if possible, the box. If you give this device to other people, please also pass on the operating instructions

GENERAL SAFETY INSTRUCTIONS

  1. Check that the voltage indicated on the appliance rating label corresponds to the voltage in the mains.
  2. Always plug the UPS into an outlet that is earthed. Risk of electric shock!
  3. Do not use the device outdoors.
  4. Do not place / use the UPS near dusty areas.
  5. Keep it away from sources of heat, direct sunlight, humidity (never dip it into any liquid) and sharp edges.
  6. Do not use the appliance with wet hands. Risk of electric shock!
  7. Do not place /use the UPS on or near flammable material and sources of heat.
  8. Do not place/ use the appliance near places with very high or very low temperatures (above 40°C or below 0°C).
  9. Do not place/ use the appliance near places with a very high humidity level (above 90%).
  10. Do not place/ use the appliance near places with severe vibration.
  11. Charge the UPS battery for at least 8 hours before using the device for the first time.
  12. If the UPS is not used for a long time, charge the battery for at least 8 hours before use it in order to avoid damage.
  13. UPS is designed exclusively for use with computers only.Do not connect the device to other induction or capacitive load devices e.g. laser printers or scanners.
  14. It is prohibited to use the UPS with vital support devices because in the event of failure, the devices will stop working. Violation of this particular security and liability is solely the responsibility of the user.
  15. WARNING: Do not operate the appliance with a damaged cord. In order to avoid the risk of an electric shock, never try to repair the appliance by yourself. Bring it to the authorized service station for repair.
  16. WARNING: II is hazardous for anyone other than a trained person to carry out any service or repair operation which involves the removal of cover of UPS. To reduce risk of electric shock, UPS should be only be opened by an authorized technician when service is required.
  17. WARNING: Do not place objects containing water or any other liquid on the UPS in order to avoid the risk of a short circuit .  Risk of electric shock! Risk of fire!
  18. To protect again electric shock, do not immerse the cord, plug or unit in water or any other liquid.
  19. In case of fire, use a dust extinguisher. The use of a liquid extinguisher is prohibited .  Risk of electric shock!
  20. Do not place objects on the UPS.
  21. CAUTION: Do not connect devices load higher than UPS can handle.
  22. Place the device on a flat and stable surface.
  23. Keep a distance of at least 15cm around all sides of UPS.
  24. When cleaning or storing the device, switch off the appliance and always pull out the plug from the socket (pull the plug, not the cable).
  25. Keep the device and its cord out of the reach of children.
  26. In order to ensure your children’s safety, please keep all packaging {plastic bags, boxes, polystyrene etc.) out of their reach. WARNING: Do not allow small children to play with the foil. Danger of suffocation

PARTS IDENTIFICATION

FRONT PART

  1. Power ON /OFF button
  2. LED light indications
  3. Ventilation holes
BACKSIDE PART

  1. Outputs
  2. Power cord

LED LIGHT INDICATIONS AND NOTIFICATIONS

STATUS LED SOUND NOTIFICATION NOTES

6S0VA \ 850VA \ 1200VA \ lS00VA \ 2000VA

AC Power supply

Green LED light (battery-fully-charged)

Yellow LED light (charging)

Battery (DC) power supply

Red-LED-light

Sound notification every 6 seconds

Exhausted battery or battery overheat

Red LED light

Continuous sound notification

Notice to close the computer

USING THE UPS

  1. Before using the UPS for the first time, check that the voltage shown an the device rating label corresponds to the voltage in the mains.
  2. Charge the battery for at least 6-8 hours before use it in order to avoid damage.
  3. Turn the devices off and disconnect them from the power supply.
  4. Connect the load (e.g. computer) ta the outlet on the back side of UPS.
  5. Connect UPS ta the power supply.
  6. Press the UPS power button far 2 seconds and the green LED will illuminate.
  7. Turn an your computer.

Test that the UPS is working properly:

Let the UPS work in battery made far a short period of time.

  1. Disconnect the UPS power plug in order ta simulate a power failure.
  2. An audible alarm should sound and the red LED will light .
  3. If it works as above, then UPS is working properly.

Otherwise contact the retail store that you bought the device or the authorized service.

CLEANING

  1. Always unplug the device before cleaning it.
  2. Clean the device housing with a damp cloth.
  3. Do not use anything abrasive that can scratch or damage the device.
  4. Do not use a wire brush or other abrasive utensils far cleaning.

STORAGE

  1. Always unplug the device before storing it.
  2. Always store the device in a safe and clean place. For the better protection of the appliance, store it in its original packaging.

TECHNICAL SPECIFICATIONS

MODEL

650VA 850VA 1200VA 1500VA

2000VA

Input voltage

220V AC± 25% (5% adjustable)

Input frequency

50Hz / 60Hz ± 6%

Output frequency

50Hz / 60Hz ± 1%

Output voltage

220V AC (±5%,adjustable)

Transfer time

<10ms

Waveform type

Sine wave under constant grid voltage, Square waveform during battery operation

Overload protection

Safety for overload

Short circuit protection

Safety for power failure and short circuit operation

Battery backup time

15 -35 min (depending on the load)

Battery type

12V 7 .2Ah xl

12V9Ah xl

12V 7 .2Ah x2

12V9Ah x2

12V9Ah x2

Battery protection

Automatic operation control, discharge protection and battery error warning

Battery charging time

6 hours for 90%

Battery life time

3 months

Low battery sound notification

Sufficient battery capacity- Sound notification every 6 seconds\ LED light flashes

Battery/ overload/ short circuit sound notification

Insufficient battery capacity-Sound notification every 1 second\ LED light flashes

Continuous sound notification\ LED light is ON

Temperature

0°C-40°C

Humidity

0%-90%

Noise

< 40dB at l.0m distance

Schuko outputs

2

2 4 4

4

Net weight (Kg)

4.7

4.75 9.5 11.7

11.7

Device dimensions (mm):

335x87x143

335x87x143 312x122x195 360x122x195

360x122x195

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
LED light indications do not light up. Problem with power Supply Check that the power cord is properly connected.
Burned fuse on the back side of the UPS After unplugging, take the fuse out and check if it is

LED light indications do not light up. burned or not. In case that fuse is burnt, you should contact the authorized service.

The UPS switches on in less than 3 seconds To turn on the UPS you need to press the power button for more than 3 seconds.
The UPS does not work through AC power (AC) (you have plugged in the device, power outlet has been switched on and you have pressed the power button but the LED light does not light up and audible notification sounds). Problem with power supply Check that the power cord is properly connected.
Burned fuse on the back side of the UPS After unplugging, take the fuse out and check if it is burned or not. In case that fuse is burnt, you should contact the authorized service.
The red LED lights up and an audible notifications sounds continuously. Overload \ Battery voltage is too low Reduce the load\ Charge the battery for at least 8 hours
Battery discharge time is shorter than usual. The battery is not charged properly Charge the battery for at least 8 hours and double check the discharge time. If the discharge time is again shorter than usual, you should contact the authorized service.
Faulty battery Reduce the load\ Charge the battery for at least 8 hours
Problem while charging the battery Charge the battery for at least 8 hours and double check the discharge time. If the discharge time is again shorter than usual, you should contact the authorized service.