Numatic KIT-HS1 HENRY & HETTY ECO (420W) Instructions

Numatic KIT-HS1 HENRY & HETTY ECO (420W)

Kit HS1

Assembly

Using your machine

Cleaning your machine

Fitting the Face

Removing the Face

Wand Docking

Tool Tidy

Cleaning the Floor Tool

About your machine

1 Voltage / Supply
2 Frequency
3 Rated Input Power
4 Weight (ready to work)
5 Company Name & Address
6 Model
7 Machine yr/wk Serial Number
8 WEEE Logo
9 Protection Class 2 Symbol
10 CE Mark

MAINTENANCE

  • Daily Keep the machine clean, including hoses and tubes.
  • Ensure the bag and filter are fitted.
  • Regularly examine the power cord.
  • Check dust bag frequently.
  • Check filters are clean.
  • Weekly – as daily and:- Check for any worn or damaged parts and replace immediately.

WEEE Legislation (Waste, Electrical and Electronic Equipment)Vacuum cleaner, accessories and packaging should be sorted for environmentally – friendly recycling.(Only for EU Countries)Do not dispose of vacuum cleaner into household waste! According to the European Directive 2012/19/EU on waste electrical and electronic equipment and its incorporation into national law.Vacuum cleaners that are no longer suitable for use must be separately collected and sent for recovery in an environmentally – friendly manner.

PPE (personal protective equipment). That may be required for certain operations.

NOTE: A risk assessment should be conducted to determine which PPE should be worn.

Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or the Numatic Technical helpline +44 (0)1460 269268

Information for DRY use Vacuum cleaners

WARNING

  • Read the instruction manual before using the machine.
  • Operators shall be adequately instructed on the use of their machine.
  • As with all electrical equipment, care and attention must be exercised at all times during use, in addition to ensuring that routine and preventative maintenance is carried out periodically to ensure safe operation.
  • Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render this equipment unsafe and the manufacturer can accept no responsibility in this respect.
  • Maintenance should only be carried out by a qualified person.
  • This machine is for DRY USE only and must not be stored outside or used in wet conditions.
  • The machine shall be disconnected from the mains by removing the plug from the supply socket during cleaning or maintenance and when replacing parts or converting the machine to another function.
  • Only use the socket outlet on the machine for purposes specified in the instructions (if fitted).
  • This machine is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge.
  • This appliance is intended to be cleaned and maintained by an adult.
  • Children being supervised are not to play with the machine.
  • This machine is not a toy.
  • This machine is not suitable for picking up hazardous or explosive dust.
  • Contact your local distributor if you require a machine capable of performing these tasks.

CAUTION

  • Ensure that the filtration system fitted to the machine is suitable for the material being collected.
  • This vacuum cleaner is intended for indoor use in the collection of dry materials.
  • This machine should be stored indoors only.

NOTES

  • The primary use for this machine is commercial, for example in hotels, schools, hospitals, factories, shops and offices. This product complies with the requirements of clause 20 of IEC/EN 60335-2-69 Stability and Mechanical Hazards.
  • This vacuum cleaner is fitted with a thermal protection device. If the vacuum cleaner stops working, remove the plug from the wall before investigating where the fault lies.
  • If the vacuum cleaner has a blockage, switch off, remove the plug from the socket, inspect the floor tool, tubes and hose for debris. If the floor tool, tubes and hose are clear, replace the dust bag and clean the filter.
  • The vacuum cleaner should be inspected after use for damage.
  • The vacuum cleaner should be stored in a dry place.
  • When moving from one place to another, consider the weight of the machine.

DO

  • Keep your machine clean including hoses and tubes.
  • Change dust bag frequently.
  • Keep filters clean.
  • Keep diffuser filter (where fitted) clean.
  • Use filter bags, they will enhance performance and help keep machine clean.
  • Use a Numatic Original filter bag under fine dust conditions.
  • Keep hoses and tubes clear.
  • Replace any worn or damaged parts immediately.
  • Only use the brushes provided with the machine. The use of other brushes may impair safety.
  • Regularly examine the power cord. If damage is found such as cracking or ageing the power cord must be replaced by a qualified person.
  • Only replace the power cord with the correct Numatic approved replacement part.

DO NOT

  • Pull on the cable to unplug the machine from the power supply.
  • Use to suck up hot ashes or lighted cigarette ends.
  • Use steam cleaners or pressure washers to clean the machine or use in the rain.
  • Immerse in water for cleaning.
  • Attempt machine maintenance or cleaning unless the power supply plug has been removed from the supply outlet.
  • Use in wet environments or to collect wet materials.
  • Under any circumstances place foreign objects including (but not limited to) air fresheners, air freshener capsules or scented beads of any type into the top filter of the machine. Doing so can be dangerous and risk damage to the machine and may invalidate the machine warranty.

Schematic Diagram

Replacement Parts

TriTex Filter
909560 TriTex-Filter
HepaFlo Bags
909291 NVM 1CH (Pack of 3)
907076 NVM 1CH (Pack of 5)
907075 NVM 1CH (Pack of 10)

Data

1 2 3 4 5 6
Drum Size Cleaning Range Weight (Ready to work) Sound Pressure Protection Class Dimensions
1 2 3 4 5 6
6L 26.1 m 7.5 kg LpA ≤ 70 dB(A) Class II 320 mm x 340 mm x 345 mm (W x L x H)

Numatic International Limited. Chard, Somerset, TA20 2GBTelephone: 01460 68600 Fax: 01460 68458© Numatic International Limited