REMINDERCALL 1-866-627-3435BEFORE RETURNING TO STORE.Information about these operating instructionsWelcome to OASE Living Water. You made a good choice with the purchase of this product AquaMax Eco Classic 1200/1900/2700/3600. Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions.Adhere to the safety information for the correct and safe use of the unit. Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner.WARNINGS AND CAUTIONS SYMBOLSSymbols used in these instructionsThe symbols used in this operating manual have the following meanings:Risk of injury to persons due to dangerous electrical voltage.This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.Risk of personal injury caused by a general source of danger.This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pacemakers.Important information for trouble-free operation.Intended useAquaMax Eco Classic 1200/1900/2700/3600, referred to in the following as “unit”, may only be used as specified in the following:

  • For pumping normal pond water for filters, waterfalls, and watercourses.
  • Operation under observance of the technical data.The following restrictions apply to the unit:
  • Do not use it in swimming pools.
  • Never use the unit to convey fluids other than water.
  • Never run the unit without water.
  • Do not use it for commercial or industrial purposes.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable, or explosive substances.
  • Do not connect to the domestic water supply.

Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pacemakers.Use other than that intendedThis unit can be dangerous and cause harm if not used in accordance with these instructions. Any use not in accordance with these instructions or modification(s) to the unit will void the limited warranty.WARNINGRisk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

Installation and connection

Attention! Dangerous electrical voltage.Possible consequences: Death or serious injuries due to operation of this unit in a swimming pond.Protective measures:

  • Do NOT use this unit in a swimming pond.
  • Adhere to national and regional regulations.

Attention! Dangerous electrical voltage.Possible consequences: Death or serious injuries.Protective measures:

  • Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water.
  • Isolate the unit before starting any work.
  • Secure the unit to prevent unintentional switching on.

Important:

  • The unit can be placed submerged or dry.
  • Always place the unit below water level.
  • It is recommended to place the unit horizontally on the ground ensuring its stable position.

Operating the unit in the pondThe pump is in the pond. The return system, e.g.a pond filter is connected to the pump outlet.

  1. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
  2. Shorten the stepped hose adapter to the diameter of the hose used if necessary This reduces pressure losses.Align the stepped hose adapter prior to tightening the union nut.
  3. Connect the hose with the stepped hose adapter and secure it with a hose clip.

Questions, problems, missing parts?Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at [email protected]. Or visit our website at www.oase-livingwater.com

Installation and connection

Install the unit at a dry placeInstall the unit so that it is not exposed to direct sun radiation.

  1. Remove screws. The screws are used as transport protection and not required for operation.
  2. Actuate the engagement hook and fold up the strainer top casing.
  3. Remove pump.
  4. Screw the stepped hose adapter including the sealing ring onto the inlet.
  5. Shorten the stepped hose adapter to the diameter of the hose used if necessary.• This reduces pressure losses.
  6. Connect the hose with the stepped hose adapter and secure it with a hose clip.• Align the stepped hose adapter prior to tightening the union nut.
  7. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
  8. Shorten the stepped hose adapter to the diameter of the hose used if necessary.• This reduces pressure losses.• Align the stepped hose adapter prior to tightening the union nut.
  9. Connect the hose with the stepped hose adapter and secure it with a hose clip.

Start-up

Attention! Sensitive electrical components.Possible consequences: The unit will be destroyed.Protective measures: Do not connect the unit to a dimmable power supply.This is how to connect the power supply:

  1. Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
  2. Switching off: Disconnect the unit from the mains.

Important:

  • When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length (Environmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump switches off automatically after approx. 90 seconds if it runs dry (is blocked). In the event of a malfunction, disconnect the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.

Maintenance and cleaning

Attention! Dangerous electrical voltage.Possible consequences: Death or serious injuries.Protective measures:

  • Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the water.
  • Isolate the unit before starting any work.
  • Secure the unit to prevent unintentional switching on.

Cleaning the unitNote!Recommendation on regular cleaning:

  • Clean the pump at least twice a year.
  • Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the function.
  • Recommended cleaning agent for removing stubborn limescale deposits:• Vinegar- and chlorine-free household cleaning agent.
  • After cleaning, thoroughly rinse all parts in clean water.

Clean the pump

  1. Screw off the stepped hose adapter.
  2. Remove screws.• The screws are used as transport protection and not required for operation.
  3. Actuate the engagement hook and fold up the strainer top casing.Questions, problems, missing parts?Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at [email protected]. Or visit our website at www.oase-livingwater.com
  4. Remove pump.
  5. Remove screws.
  6. Remove the pump housing including its holding ring, sealing, and impeller unit.• Clean all components under running water using a soft brush, replace damaged parts.
  7. Reassemble the unit in reverse order.• Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.

Storage/Winterization

  • Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
  • Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!

Wear partsThe impeller unit is a wearing part and does not fall under the warranty.RepairA damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regulations.DisposalDo not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further information about the recycling of this product can be obtained from your local municipal authority.

Troubleshooting

Issue Cause

Solution

The pump does not start No mains voltage Check mains voltage; Check supply lines
The pump does not deliver Filter housing clogged Clean strainer casings
Insufficient delivered quantity Filter housing clogged Clean strainer casings
Excessive loss in the supply lines
  • Select larger hose diameter
  • Adapt stepped hose adapter to hose diameter
  • Reduce hose length to reduce frictional loss
  • Avoid unnecessary connection elements
The pump switches off after a short running period Excessively soiled water Clean pump. The pump automatically switches on again once the motor has cooled down.
Water temperature too high Note maximum water temperature of 95 °F (+35 °C). The pump automatically switches on again once the motor has cooled down
The pump has run dry Flood pump. Fully submerge the unit when operated in the pond.
Impeller unit blocked Disconnect the power supply and remove obstacles. Then switch the pump on again.

Questions, problems, missing parts?Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at [email protected]. Or visit our website at www.oase-livingwater.com

Model

ModelNo. Ratedvoltage Powerconsumption Max. flowrate Max. headheight Immersiondepth Cordlength Weight Watertemperature Connection for hoses

Dimensions

1200 40347 120V AC/ 60 Hz 45 W / max. 1.3 A 5 1.200 gph5 4.560 1/h 5 8.2 ft5 2.5 m max. 13 ftmax. 4 m 20 ft6 m 9.7 lbs4.4 kg 39 … 95 °F+4 … +35 °C 1″ / 1-1/4″ / 1-1/2″25 / 32 / 38 mm 11 x 9 x 5.5 in.279 x 230 x 140 mm
1900 57620 70 W / max. 1.4 A 5 1.900 gph5 7.200 I/h 5 9.5 ft5 2.9 m
2700 57621 110 W/ max. 1.5 A 5 2.700 gph5 10.200 I/h < 10.8 ft5 3.3 m 11 lbs5 kg
3600 57623 150 W / max. 1.8 A 5 3.600 gph5 13.700 1/h 5 13 ft5 4 m
Dust-tight. Submersible 13.3 ft (4 m) depth. Remove the unit at temperatures below zero (centigrade) Possible hazard for persons wearing pacemakers! Protect from direct sun radiation Do not dispose of it together with household waste! Attention!Read the operating instructions

Pos.

AquaMax Ego Classic

1200 1900 2700 3600
1 21904 21904 21904 21904
2 21906 21906 21907 21907
3 21902 21902 21902 21902
4 40760 22817 21914 21914
5 40761 22818 22836 22837
6 10143 10143 10143 10143

OASE North America INC.www.oase-livingwater.com23795/01-17