OONO 50 Amp Forward & Reverse Relay Module User Manual

CZH-LABS.com50 Amp Forward & Reverse Relay ModuleModel: F-1021 series

Features:

  • Reversing relay module. Powers any reversing motor equipment, can be used for any application that requires the ability to reverse motion.
  • Support Momentary-action(Self-resetting) switch and Alternate-action (Self-holding) switch. For the Self-resetting switch, when the switch is pressed the motor operates, and when the switch is released the motor stops.
  • High-quality aluminum enclosure, thickness 1.5mm/0.06″. Diameter M6 / 6mm threaded copper terminals for battery and load. Connect switch terminal block: pitch 5.0mm/0.197″, wire size 26~12 AWG / 2.5mm square, stripping length 7mm/0.28″, Metric M2.5 slotted screw.
  • Power on indicating red LED. Forward and Reverse status indicating LED, forward status lighting red reverse lighting green.
  • Operating voltage: 10~15VDC or 20~30VDC, Rated current: 50 Amp.

Specifications:

12V Version 24V Version
Operating voltage 10 – 15V DC 20 – 30V DC
Switch short current 150mA @12V 75mA @24V
Switch disconnect voltage = V+
Load rated current 50A
Static current consumption 0.5mA (for power on LED)

Action Status:

FWD Switch REV Switch M1 Voltage M2 Voltage Motor Status
Disconnect Disconnect V+ V+ Stop
Connect Disconnect V+ OV Forward
Disconnect Connect OV V+ Reverse
Connect Connect OV OV Stop

Wiring diagram:

For Momentary-action(Self-resetting) switch

For Alternate-action(Self-holding) switch:

Dimensions:

References