Philio PSE04 Multiple Sound Siren User Manual

Multiple Sound Siren PSE04

The PSE04 is a wireless siren, based on Z-Wave technology. It is the Z-Wave™ plus product, it supports the security, OTA… Those newest features of the Z-Wave™ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems, and household appliances.

This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.

The device adopts the Z-Wave™ 700 series chip when your Z-Wave™ network system is all made by Z-Wave™ 700 series devices. The network system will have the advantages as below.

  • Concurrent multi-channel support reduces external interference.
  • Better RF range, improve about 10 meters in indoor.
  • Support 100 Kbps transmit speed, speed up communication.

Specification

Rating 6VDC (AA Battery *4)
RF distance Min. 40M indoor,100M outdoor line of sight,
RF Frequency 868.40 MHz, 869.85 MHz(EU)908.40 MHz, 916.00 MHz(US)920.9MHz, 921.7MHz, 923.1MHz(TW/KR/Thai/SG)921.40 MHz, 919.80 MHz(ANZ)869.00 MHz(RU)865.20 MHz(IN)916.00 MHz(IL)
RF Maximum Power +10dBm (Peak), -10dBm(Average)
Dimension 170mm(L) X 48mm (W) X 30(H)
Weight 205g
IP classification IP44; Outdoor use
Operation temperature -20 to 55° C
Humidity 85%RH max
FCC ID RHHPSE04
Marking CE/NCC

* Specifications are subject to change and improvement without notice.

Troubleshooting

Symptom Cause of Failure Recommendation
The device can not join to Z-Wave™ network The device may be in a Z- Wave™ network. Exclude the device then include it again.

For Instruction to

http://www.philio-tech.com

Overview

Battery Installation

When the device reports a low battery message. The user should replace the battery with a new one. The battery type is AA, 1.5V Please loosen the screw on the back cover to  release the front cover

Adding to Z-Wave™ Network

There is one tamper key on the device. The tamper key can add, remove, reset from the Z-Wave™ network.In the first time, add the device into the Z-Wave™ network. First, make sure the primary controller is in the add mode. And then power on the device. The device will auto start the smart start Inclusion mode.Notice: Including a node ID allocated by Z-Wave™ Controller means “Add” or “Inclusion”. Excluding a node ID allocated by Z-Wave™ Controller means “Remove” or  “Exclusion”..

Function

Description

Add 1. Have Z-Wave™ Controller entered inclusion mode.2. Press the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successfully, the LED will light ON 1 second
Remove 1. Have Z-Wave™ Controller entered exclusion mode.2. Press the tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded.
Reset Node ID has been excluded.Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Press the tamper key four times within 1.5 seconds and do not release the tamper key in the 4 pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second.Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.
SmartStart 1. Product has a DSK string, you can key in the first five-digit to increment the SmartStart process,or you can scan a QR code. Ex:desk 10209-46687-52248- 13629-04783-07465-15776-565192. SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave QR Code present on the product providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of minutes On in the network vicinity.*notice1:The QR code can be found on the device PSE04 or on the box.
Association This machine provides one group of nodes. Each group can set 1 Node.

Group 1: Used for returned events. Report type:1. Notification report2. Sensor multilevel report3. Device Reset Locally Notification4. Battery Report5. Indicator Report

• Failed or successful in including/excluding the node ID can be viewed from Z-Wave™ Controller.

Z-Wave™ Message Report

In default, the device will use Notification Report to represent the tamper trigger event.* Tamper Report:When the tamper key is pressed over 5 seconds. The device will into the alarm state. In that state, if the tamper key be released, the device will unsolicited to send the report to the nodes in group 1.

Notification Report (V8)Notification Type: Home Security (0x07)Event: Tampering. Product covering removed (0x03)

* Siren State Report:When the siren starts playing or stops the alarm sounds, the device will unsolicited to send the “Notification Report” to the nodes in the group1.

Notification Report (V8)Notification Type: Siren (0x0E)Event: Siren active (0x01) , Siren idle (0x00)

*Temperature Report:When the temperature differential is over, the device will unsolicited send the “Sensor Multilevel Report” to the nodes in the lifeline group.Sensor Type: Temperature (0x01)*** Temperature differential report ***This function default is disabled, to enable this function by setting the configuration NO.5 is greater than 0. The default is to disable temperature differential reports.If setting the configuration NO.5 to 1, when the temperature is changed to plus or minus one degree Fahrenheit (0.56 degree Celsius), the device will report temperature information to the nodes in the lifeline group.The device will measure the temperature in every 10 seconds. And if the temperature is over 140 degrees Fahrenheit (60 degrees Celsius), the device will always report each measurement.Notice 1: The PSE04 must stay awake for at least 2 seconds after communicating, so therefore the more communication, the power consumption fast, please pay attention to use configuration NO.5.Notice 2: This product cannot reflect outdoor temperature immediately because of the temperature sensor equipped inside rather than the surface.

Power Up Procedure

Play SoundUsing the SWITCH_BINARY_SET or BASIC_SET to play the siren, Basic Set or Switch Binary Set with Value 0xFF, the Sound ID will be the same as the value which was set  in Configuration No.7, 0x00 will stop to play.

Value Sound
0x00 Stop Play
0x01 Fire
0x02 Ambulance
0x03 Police
0x04 Alarm
0x05 Ding Dong
0x06 Beep
0xFF Same as configuration NO.7 setting.

Switch Binary Set (V1)

Value Sound
0x00 Stop Play
0xFF Same as configuration NO.7 setting.

Over The Air (OTA) Firmware Update

The device is supported with Z-Wave™ firmware update via OTA.

  1. Set the Z-Wave™ Controller into the firmware update mode.
  2. Choose the hex file to update the firmware.
  3. Wait 10~15 minutes for completing the OTA process.
  4. Result of OTA will show in the Z-Wave™ Controller log.

During the OTA process, please DO NOT remove the power, otherwise, the firmware will be broken, and the device will be nonfunctional.

Z-Wave™ Configuration Settings

Notice 1: All of the configurations, the data size is 1.Notice 2: The reserved bit or not supported bit is allowed any value, but no effect.Notice 3: The PSE04 must stay awake for at least 2 seconds after communicating, so therefore the more communication, the power consumption fast, please pay attention to use configuration NO.1, NO.4, NO.5, NO.6.

NO.

Name Def. Valid

Description

1 Auto ReportTick Interval 0x1E 0~255 The interval time for auto report each tick.
2 Sound 0x06 0~127 Play sound duration, 1 tick is 30
Duration seconds.
3 CustomerFunction 0x00 All Customer function switch, using bit control.
0 Bit0: Disable Trigger Alarm.0: Enable, 1:Disable.
0 Bit1: Disable Sound. Only using the optical alarm. 0:Enable, 1:Disable.
0 Bit2: Temperature Unit.0:Fahrenheit, 1:Celsius.
0 Bit3: Reserve.
0 Bit4: Reserve.
0 Bit5: Reserve.
0 Bit6: Reserve.
0 Bit7: Reserve.
4 Auto Report Temperature Time 0x0C 0~127 The interval time for auto report the temperature.
5 Temperature Differential Report 0x00 0~127 The temperature differential to report.
6 Auto ReportBattery Time 0x0C 0~127 The interval time for auto report the battery level.
7 Play Sound

Control

0x41 All Control play sound’s level and which sound.
1 Bit0~1: Play sound’s level. Level

1~3.

0 Bit2: Reserve.
0 Bit3: Reserve.
4 Bit4~7: Which sound id will play when control forms controller. Sound ID 1~6, 0: Disable.

Z-Wave Supported Command Class

Command Class Version Required Security Class
Z-Wave Plus™ Info 2 None
c
Supervision 1 None
Transport Service 2 None
Association 2 Highest granted Security Class
Association GroupInformation 3 Highest granted Security Class
Device Reset Locally 1 Highest granted Security Class
Firmware Update MetaData 5 Highest granted Security Class
Indicator 3 Highest granted Security Class
Manufacturer Specific 2 Highest granted Security Class
Multi-Channel Association 3 Highest granted Security Class
Powerlevel 1 Highest granted Security Class
Version 3 Highest granted Security Class
Configuration 4 Highest granted Security Class
Sensor Multilevel 11 Highest granted Security Class
Basic 1 Highest granted Security Class
Switch Binary 1 Highest granted Security Class
Notification 8 Highest granted Security Class
Battery 1 Highest granted Security Class

CAUTIONRisk of explosion if the battery is replaced by an incorrect type.Dispose of used battery according to the instructions.Choosing a Suitable Location

  1. The suitable ambient temperature for the module/device is 0°C~40°C.
  2. Do NOT place the module/device direct under sunlight, in a humid place or in any location where they may contact moisture, dirt, dust.
  3. Do NOT place the module/device where exists combustible substances or any source of heat, fires, radiators, boiler etc.

Disposal

This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Philio Technology Corporation8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C)www.philio-tech.com

FCC Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful  interference to radio or television reception, which can be determined by turning the equipment off and on, the user  is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: