Controls overview

Getting started

Installing the filter

Note: Make sure the air purifier is unplugged from the electrical outlet before installing the filter.

  1. Pull the back cover and remove it from the appliance.
  2. Pull the filter from the appliance.
  3. Remove all packaging materials of the air purification filter.
  4. Put the filter back into the appliance.
  5. Reattach the back cover.
Wi-Fi indicator
Wi-Fi icon status Wi-Fi connection status
Blink in orange Connecting to the smartphone
Blink in white Connecting to the router
Stable in white Connected to the router
Off Wi-Fi function disabled
Wi-Fi connection

First-time connection

  1. Download and install the Philips “Clean Home+” app from the App Store or Google Play.
  2. Connect your smartphone or tablet to your Wi-Fi network.
  3. Launch the “Clean Home+” app and click on “Connect a New.

Device” or press the “+” button on the top of the screen. Follow the on-screen instructions to connect the air purifier to your network.

Reset the Wi-Fi connection

  1. Touch and for seconds until you hear a beep.The Wi-Fi indicator blinks orange.
  2. Follow steps 3 in the “First-time connection” section.Note: Please check www.philips.com/cleanhome for the latest update of supported Operation systems and devices.

Using the air purifier

Air quality light

After approximately 30 seconds, the particle sensor selects the color that corresponds to the surrounding air quality of airborne particles.Note: The color of the air quality light is determined by the highest risk index among PM2.5, IAI, and readings.

PM2.5 refers to airborne particle pollutants smaller than 2.5 micrometers.

PM2.5 level Air quality light color Air quality level
.60 Blue Good
61-120 Blue-purple Fair
121-250 Purple-red Poor
>250 Red Very poor

IAI refers to the level of indoor air allergen.

IAI level Air quality light color Air quality level
1-3 Blue Good
4-6 Blue-purple Fair
7-9 Purple-red Poor
10-12 Red Very poor
Turning On and Off

Note:

  • Put the plug of the air purifier in the power socket.
  • If the purifier stays connected to the electrical outlet after turning it OFF, the air purifier will operate under the previous settings when turned ON again.
  • Touch to switch on the air purifier.
  • The “ ” displays on the screen during warming up. Then the air purifier shows the PM2.5/IAI level after measuring the air quality.
  • The air purifier operates in auto mode with PM2.5 displayed on the screen.
  • Touch and hold the button for 3 seconds to switch off the air purifier.
Changing the mode setting

You can choose Auto mode, Turbo mode, Gentle mode, or Sleep mode by touching the button.

Auto mode ( ): The air purifier automatically adjusts the fan speed in accordance with the ambient air quality.

Turbo mode ( ): The air purifier operates at the highest speed.

Gentle mode ( ): The air purifier operates at a low speed.

Sleep mode (): The air purifier operates quietly at a low speed. After 3 seconds, the screen lights off.

Switching the display indicator

Note:

  • The appliance display PM2.5 level by default.
Using the light on/off function

You can touch the light on/off button manually to turn off all lights and the control panel. Touch any button to wake up all lights.With the light sensor:

  • The control panel can automatically turn on, turn off or dim according to the ambient light.
  • The control panel will be off or dim when the ambient light is dark.

You can touch any button to wake up all lights. If no further operation, all lights will be off or dim again to match with the ambient light.

Checking the filter status
  • Touch the filter status check/reset button to check the filter service life status.
Icon color Display (%)
Blue 16-100
Blue-purple 9-15
Purple-red 4-8
Red 0-3

Note: The appliance goes back to normal display if no operations after 3 seconds.

Cleaning and maintenance

Note:

  • Do not attempt to clean the particle sensor with a vacuum cleaner.
  • witch off the air purifier and unplug from the power socket before the following action.
Cleaning the body of the air purifier

Use a soft, dry cloth to clean both the interior and exterior of the air purifier and the air outlet.

Cleaning the particle sensor

Clean the particle sensor every 2 months for optimal functioning of the appliance.

  1. Clean the particle sensor inlet and outlet with a soft brush.
  2. Clean the particle sensor with a damp cotton swab. Dry all parts thoroughly with a dry cotton swab.
Cleaning the surface of the filter

Clean the surface of the filter with a vacuum cleaner when the filter cleaning alert is displayed on the screen.

  1. Pull the back cover and remove it from the appliance.
  2. Pull the filter from the appliance.
  3. Clean the surface of the filter with a vacuum cleaner.
  4. Put the filter back into the appliance.
  5. Reattach the back cover.
  6. Touch the button to switch on the appliance.
  7. Touch and hold the filter status check/ reset button for 3 seconds to reset the filter cleaning time.
  8. Wash your hands thoroughly after cleaning the filter.
Replacing the filter

Note:

  • The filter is not washable or reusable.
  • Do not smell the filter as it has collected pollutants from the air.

When the filter needs to be replaced, the filter replacement alert lights up red.

  1. Replace the filter with Philips NanoProtect filter Series 3 (FY2180/10) , Please follow the step of Chapter “Installing the filter”.
  2. Touch the button to switch on the appliance.
  3. Touch and hold the filter status check/ reset button for 3 seconds to reset the filter replacement time.
  4. Wash your hands thoroughly after replacing the filter.

Filter reset

You can also replace the filter before filter replacement alert ( ) displays on the screen. After replacing a filter, you need to reset the filter lifetime counter manually.

  1. Touch the power button for 3 seconds to turn off the appliance and unplug from the power socket.
  2. Put the power plug in the power socket.
  3. Within 15 seconds after power-on, touch and hold and button for 3 seconds to reset the filter lifetime counter.

Storage

  1. Turn off the air purifier and unplug from the power socket.
  2. Clean the air purifier, particle sensor, and the surface of the filter (see the chapter “Cleaning and maintenance”).
  3. Let all parts air dry thoroughly before storing.
  4. Wrap the filter in air-tight plastic bags.
  5. Store the air purifier, filter in a cool, dry location.
  6. Always thoroughly wash your hands after handling filters.

Troubleshooting

This chapter summarizes the most common problems you could encounter with the appliance. If you are unable to solve the problem with the information below, contact the  Consumer Care Center in your country.

Problem Possible solution
The appliance does not work properly. • The filter replacement alert has been on continuously but you have not replaced the corresponding filter. As a result, the appliance is now locked. In this case, replace the filter and long press to reset the filter lifetime counter.
The airflow that comes out of the air outlet is significantly weaker than before. • The surface of the filter is dirty. Clean the surface of the filter (see the chapter “Cleaning and maintenance”).
The air quality does not improve, even though the appliance has been operating for a long time. • Check if the packing material is removed from the filter.• The filter has not been placed in the appliance. Make sure that the filter (FY2180/10) is properly installed.• The particle sensor is wet. The humidity level in your room is high and causes condensation.  Make sure that the particle sensor is clean and dry (see the chapter “Cleaning and maintenance”).• Room size is large or the outdoor air quality is poor.For optimum purification performance, please close the doors and windows when operating the air purifier.• There are indoor pollution resources. For instance, smoking, cooking, incense, perfume, or alcohol.• Filter reaches the end of life. Replace the filter with a new one.
The color of the air quality light always stays the same. • The particle sensor is dirty. Clean the particle sensor (see the chapter “Cleaning and maintenance”).
The appliance produces a strange smell. • The first few times you use the appliance, it may produce a plastic smell. This is normal.  However, if the appliance produces a burnt smell even if removing filters, contact your Philips dealer or an authorized Philips service center. The filter may produce a smell after being used for a  while because of the absorption of indoor gases. It’s recommended that you reactivate the filter by putting it in direct sunlight for repeated use. If odor still exists, replace the filter.
The appliance is extra loud. • It’s normal if the appliance runs at the Turbo mode.• In the Auto mode, if the appliance is too loud, maybe the appliance runs at high speed because of air quality becoming worse, or your personalized setting in App triggers a higher fan speed. You can choose the Sleep mode, or change the settings in the app.• If anything drops into air outlet, it may also cause abnormal loud sound. Immediate turn off the appliance, turn appliance upside down, to get foreign objectives out of the appliance.• If there is an abnormal sound, contact the Consumer Care Center in your country.
The appliance still indicates that I need to replace a filter, but I already did. • Perhaps you did not reset the filter lifetime counter. Switch on the appliance. Then touch and hold the reset button () for 3 seconds.
Error code “E1” displays on the screen. • The motor has malfunctioned. Contact the Consumer Care Center in your country.
The Wi-Fi setup is not successful. • If the router your purifier is connected to is dual-band and currently it is not connecting to a  2.4GHz network, please switch to another band of the same router (2.4GHz) and try to pair your purifier again.5GHz networks are not supported.If your purifier is connected to a dual-band router, please switch to the 2.4GHz network of the router and try to pair your purifier again.• Web authentication networks are not supported. Public Wi-Fi such as an office or hotel networks are not supported.• Check if the purifier is within range of the Wi-Fi router. You can try to locate the air purifier closer to the Wi-Fi router.• Check if the Wi-Fi password is correct. The password is case-sensitive.• Retry the setup with the instructions in the section “Reset the Wi-Fi connection”.• Keep the appliance away from other electronic devices that may cause interferences.• Check if the mobile device is in airplane mode. Make sure to have the airplane mode deactivated when connecting to the Wi-Fi network.• If the Wi-Fi pairing fails after trying several times, please turn of the cellular data on your smartphone in the Settings section and start the pairing again.• If the Wi-Fi icon on your purifier’s display is in stable white but without seeing the purifier in your app, click on “Connect a New Device” and add the purifier from the local list on the “Begin setup” page.• Consult the help section in the app for extensive and up-to-date troubleshooting tips.