Qubino GOAEZMNHXD1 3 phases Smart Meter User Manual

QuintoQubino 3 phases Smart MeterSKU: GOAEZMNHXD1

QuickstartThis is a secure Smart Meter for Europe. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:Toggle the Service button S between 0.2 and 6 seconds

Important safety informationPlease read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section Z-Wave ensures reliable communication by reconfirming every message (two-way communication) andevery mains-powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in the direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise, it will automatically turn into a lower level of security to maintain backward compatibility.For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product DescriptionThe Qubino Smart Meter is an extremely versatile and powerful Z-Wave module for measuring energy in a single-phase electrical power network of up to 65A. Ain microprocessor calculates energy, power, and power factor from the measured signals. It is designed to be mounted on a DIN rail.The Qubino Smart Meter can be used in residential, industrial, and utility applications. It measures energy directly in 2-wire networks by means of fast sampling o voltage and current signals. It calculates energy, power, and power factor from the measured signals. You can control the module through the Z-Wave network. Facts as a repeater in order to improve the range and stability of the Z-Wave network. The Smart Meter is designed to be mounted on a DIN rail.

Properties:

  • Z-Wave Plus
  • EU frequency: 868.42 MHz
  • Package content: 1x Qubino Smart Meter

Main terminals (LI, NI,Lo, No)

  • Contacts capacity: 1.5…16(25)mm
  • Connection screws: M5
  • Max torque: 3.5 Nm

Optional terminals (1,2,4,5)

  • Contact capacity: 0.05 … 1 (2.5) mm
  • Connection screws: M3
  • Max torque: 0.6 Nm

Measuring input

  • Type (connection): single-phase (1b)
  • Reference current (Iref): 5 A
  • Maximum current (Imax): 65 A
  • Minimum current (Imin): 0.25 A
  • Starting current: 20 mA
  • Voltage (Un): 230 V (±20%)
  • Power consumption at Un: < 2 W
  • Nominal frequency (fn): 50 and 60 Hz

Accessory

  • IKA232-20/230 V (GOAEIKA23220)
  • BICOM432-40-WM1 (GOAEBICOM432)

Prepare for Installation / ResetPlease read the user manual before installing the product.In order to include (add) a Z-Wave device to a network, it must be in the factory default state. Please make sure to reset the device into factory default. You can do by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to the primary controller of the previous network to make sure the very device is excluded properly from this network.Reset to factory defaultThis device also allows being reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable Press and hold the S service button between 6 seconds and 20 secondsSafety Warning for Mains Powered DevicesATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

InstallationStep 1 – Turn OFF the fuse:– To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance- Be aware that even if the circuit breaker is off, some voltage may remain in the wires — before proceeding with the installation, be sure no voltage is prewiring.– Take extra precautions to avoid accidentally turning the device on during installation.Step 2 – Installing the device:– Connect the device exactly according to the diagrams shown below

Step 3 – Turn ON the fuse:

Step 4 – Add the device to your Z-Wave network:-For more details on how to include the device, please refer to the Z-Wave Inclusion chapter.Step 5 – The Installation is now complete. It’s time to make your life more comfortable with the help of the Qubino 3-Phase Smart MeterEXTERNAL RELAYS:It is possible to connect two external relays to a 3-Phase Smart Meter device. One controlled by built-in optical (IR) communication port on the side, second count output on terminal 15.* IKA and BICOM are sold separately – for more info, please see the Qubino catalog. Product ordering codes (model numbers): IKA232-20/230V: 030 046 833 0BICOM432-40-WM1: 30.074.038

Inclusion/ExclusionOn factory default, the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate withdevices of this network. This process is called Inclusion.Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. the controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.InclusionToggle the Service button S between 0.2 and 6 secondsExclusionToggle the Service button S between 0.2 and 6 seconds

Auto-InclusionBesides the standard inclusion, these devices support the so-called auto inclusion. Right after powering up the device remains in an inclusion state and can be incl(any) gateway without further actions on the device itself. The auto inclusion mode will time out after some time.Product UsageThe 3-Phase Smart Meter can be used in many different scenes, which can help make your life more comfortable. We have prepared a few of them for you soget an idea for your next smart home project. Of course, there are countless other options for how to use the Qubino 3-Phase Smart Meter to remotely control via your smartphone.

LED SIGNALIZATION FOR INCLUSION/EXCLUSIONLED1 (Green)– LED is ON = Power ON, the module is included– LED is 1s OFF, 1s ON = Power ON, module is excludedLED2 (Yellow)a. External IR relay enabled only– LED is ON = External IR relay is turned ON– LED is OFF = External IR relay is turned OFF– LED is 0.5s OFF, 0.5s ON = IR communication errorb. External TRIAC relay enabled only– LED is ON = External IR relay is turned ON– LED is OFF = External IR relay is turned OFFc. Both TRIAC and IR enabled– LED is ON = External IR relay is turned ON– LED is OFF = External IR relay is turned OFF– LED is 0.5s OFF, 0.5s ON = IR communication errord. External IR relay disabled– LED is ON = Modbus packet is sent– LED is OFF = Modbus packet is receivedQuick troubleshootingHere are a few hints for network installation if things don’t work as expected.

  1. Make sure a device is in a factory reset state before including it. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise, you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Don’t poll FLIRS devices.
  6.  Make sure to have enough mains powered devices to benefit from the meshing

Association – one device controls another deviceZ-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are all related to certain events (e.g. button pressed, sensor triggers, …). In case the event happens all devices stored in the respective association group will receive the same wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline

Configuration ParametersZ-Wave products are supposed to work out of the box after inclusion, however, certain configuration can adapt the function better to user needs or unlock further enhanced features.IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 … 255 the value sent in the application shall be the devalue minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In the case of a two-byte value, the same log applies: Values greater than 32768 may be needed to be given as negative values too.Parameter 7: Input switch function selection Available configuration parameters for input switch I1Size: 1 Byte, Default Value: 0

Setting Description
0 disabled
2 IR external relay control – monostable push button
3 IR external relay control – bi-stable switch
4 External relay control – monostable push button
5 External relay control – bi-stable switch

Parameter 40: Reporting on power changeThis parameter is valid for Active Power Total, Active Power Phase1, Active Power Phase2, and Active Power Phase3.NOTE: if the power change is less than 5 W, the report is not sent (pushed).NOTE: The device is measuring also some disturbances even if the output is no load. To disturbances:- If measured Active Power (W) is below e.g. 5W-> the reported value, in this case, is 0WSize: 1 Byte, Default Value: 50

Setting Description
0 reporting disabled
1 – 100 1% – 100% reporting enabled. Power report is sent only when actual power in Watts (in real-time changes more than set percentage comparing to previous Active Power, step is 1%.

Parameter 42: Reporting on time intervalThis parameter is currently valid only for Active Energy Total Import/Export (kWh), Reactive Energy Total (vary), Total Energy (HVAC)Note: Device is reporting only if there was a change of 0.1 in EnergyNote: In the future will be possible to measure and report also Active Energy on PH1, PHPH3.Size: 2 Byte, Default Value: 600

Setting Description
0 reporting disabled
600 – 65536 Reporting enabled. The report is sent with the time interval set by entered value. Seconds

Parameter 100: Enable / Disable External IR relay (BICOM)NOTE1: After parameter change, first exclude a module (without setting parameters to default value) and then re-include the module.NOTE 2: If you don‘t have IR BICOM relay module mounted and you enable IR communication (parameter 100 is 1 or 2) there will be no valid IR relay state reported. It will be reported IR COMMUNICATION ERROR and LED2 will BLINK.Size: 1 Byte, Default Value: 0

Setting Description
0 External relay disabled
1 External relay enabled and connected to Phase 2

Parameter 106: External IR relay (BICOM) power threshold settings – maximum power of all phases togetherThis parameter defines a threshold when the External IR relay is being turned off. (If Parameter no. 100 is set to the value 1 or 2)NOTE: Meter is capable of measuring max 3x65A!Size: 2 Byte, Default Value: 0

Setting Description
0 no function
10 – 60000 Watt

Parameter 107: External relay (IKA) power threshold settings – maximum power on phase L2This parameter defines a threshold when the External relay is being turned off (if the parameter no. 100 is set to the value 1 or 2).NOTE: Meter is capable of measuring max 65ASize: 2 Byte, Default Value: 0

Setting Description
0 no function
10 – 20000 Watt

Parameter 112: Power threshold – Delay before power onExternal IR relay/ External relay is turned off due to detected overload (as set by parameter 106&107) and remains off for a time, defined in this parameter. Lifetime, the output turns on to check if the overload is still present.NOTE: the delay time may be prolonged for more than 10s of the time set by the parameter.Size: 2 Byte, Default Value: 0

Setting Description
0 External IR relay/ External relay will not turn back on
30 – 32535 Seconds

Technical Data

Dimensions 53,6 x 84 x 65 mm
Weight 221 gr
Hardware Platform ZM5101
IAN 3.83006E+12
IP Class IP 20
Voltage 3x 230 V/400V
Load 65 A
Device Type Smart Meter
Firmware Version 1
Z-Wave Version 04.3d
Z-Wave Product Id 0x0159.0x0007.0x0054
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Switch Binary
  • Meter
  • Crc 16 Encap
  • Association Grp Info
  • Device Reset Locally
  • Zwaveplus Info
  • Multi-Channel
  • Supervision
  • Configuration
  • Manufacturer Specific
  • Powerlevel
  • Firmware Update Md
  • Association
  • Version
  • Multi-Channel Association
  • Security
  • Transport Service
  • Security 2
  • Transport Service
  • Security 2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways, Remote Controls or
  • battery-operated controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators, and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

(c) 2020 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by Z-Wave Europe GmbH. The product content is maintained by Z-Wave Europe GmbH, Support team, [email protected]. Last update of the product data: 2018-07-23 15:04:07