ResMed Swift FX Nasal Pillows System User Guide

Swift ™ FXNASAL PILLOWS SYSTEMUser Guide

Fitting 

Rx Only

Swift FX

Mask components

ItemDescription

  1. Headgear right
  2. Headgear right
  3. Backstrap
  4. Headgear left
  5. Soft wraps
  6. Pillows
  7. Short tube
  8. Swivel
  9. Swivel
  10. Elbow
  11. Swivel ring

A. Complete systemB. Complete systemC. Headgear assemblyD. Short tube assembly (Frame assembly)

Disassembly

Reassembly

NASAL PILLOWS SYSTEMThank you for choosing the Swift FX.

Intended useThe Swift FX channels airflow noninvasively to a patient from positive airway pressure (PAP) device such as a continuous positive airway pressure (CPAP) or bilevel system.The Swift FX is:

  • to be used by adult patients (> 66 lb/30 kg) for whom positive  airway pressure has been prescribed
  •  intended for single-patient re-use in the home environment and multipatient re-use in the hospital/institutional environment.

Using your maskWhen using your mask with ResMed CPAP or bilevel devices that have mask setting options, refer to the Technical specifications section in this user guide for mask selection options.For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representative.

Notes:

  • This mask is not compatible for use with ResMed AutoSet CS™ 2 and VPAP™ Adapt SV devices.
  • SmartStop may not operate effectively when using this mask with some CPAP or bilevel devices that have this feature.
  • If you experience nasal dryness or irritation, use of a humidifier is recommended.

WARNING

  • The vent holes must be kept clear.
  • The mask should not be used unless the CPAP system is turned on and operating properly.
  • Follow all precautions when using supplemental oxygen.
  • Oxygen flow must be turned off when the CPAP or bilevel device is not operating so that unused oxygen does not accumulate within the CPAP or bilevel device enclosure and create a risk of fire.
  • At a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration varies, depending on the pressure settings, patient breathing pattern, mask, point of application, and leak rate.
  • The technical specifications of the mask are provided for your clinician to check that they are compatible with the CPAP or bilevel device. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the CPAP or bilevel device function.
  • Discontinue using this mask if you have ANY adverse reaction to the use of the mask, and consult your physician or sleep therapist.
  • Using a mask may cause tooth, gum, or jaw soreness or aggravate an existing dental condition. If symptoms occur, consult your physician or dentist.
  • As with all masks, some rebreathing may occur at low CPAP pressures.
  • Refer to your CPAP or bilevel device manual for details on settings and operational information.
  • Remove all packaging before using the mask.

Cleaning your mask in the home

Your mask and headgear should only be hand washed by gently rubbing in warm (approximately 86°F/30°C) water using mild soap. All components should be rinsed well with drinking quality water and allowed to air dry out of direct sunlight.

Daily/After each use:

  • To optimize the mask seal, facial oils should be removed from the cushion after use.
  • Handwash the separated mask components (excluding headgear).
  • If the vent requires cleaning use a soft bristle brush.

Weekly:

  • Handwash the It may be washed without being disassembled.

WARNING

Do not use aromatic-based solutions or scented oils (eg, eucalyptus or essential oils), bleach, alcohol, or products that smell strongly (eg, citrus) to clean any of the mask components. Residual vapors from these solutions can be inhaled if not rinsed thoroughly. They may also damage the mask, causing cracks.

CAUTION

  • If any visible deterioration of a system component is apparent (cracking, crazing, tears or cushion damage), the component should be discarded and replaced.
  • Avoid connecting flexible PVC products (eg, PVC tubing) directly to any part of the mask. Flexible PVC contains elements that can be detrimental to the materials of the mask and may cause the components to crack or break.

Reprocessing the mask between patientsOnly Sleep Lab Mask (SLM) variants of the mask are intended for multi-patient re-use. When using between patients, these masks must be reprocessed according to cleaning and disinfection instructions available on ResMed.com/downloads/masks.

Troubleshooting

Problem / possible cause Solution
Pillows won’t seal properly, are uncomfortable or cause red marks
Pillows may have been fitted incorrectly, adjusted incorrectly or the headgear is too tight. Check that the ResMed logo on top of the pillows is facing outwards. Carefully follow the fitting instructions. Readjust the headgear to ensure it is not over-tightened.
Inner wall position of one or both pillows is incorrect. Squeeze pillow sides to release the inner wall. The correct position is shown in the reassembly instructions.
Pillows are the wrong size. Talk to your clinician.
Pillows may be dirty. Clean pillows according to the instructions.
Mask is too noisy
The system is assembled incorrectly. Disassemble the mask, then reassemble according to the instructions.
The system is leaking air. Refit or reposition you mask. Adjust your headgear.Check your mask is assembled correctly.
The vent is blocked or partially blocked. If the vent requires cleaning, use a soft bristle brush.

Technical specifications

Pressure–flow curve The mask contains passive venting to protect against rebreathing. As a result of manufacturing variations, the vent flow rate may vary.
Dead space information Physical dead space is the empty volume of the mask to the end of the swivel. Using the large cushions it is 106 mL.
Therapy pressure 4 to 20 cm H2O
Resistance Drop-in pressure measured (nominal) at 50 L/min: 0.4 cm H2O at 100 L/min: 1.4 cm H2O
Environmental conditions Operating temperature: +41°F to 104°F (+5°C to +40°C)Operating humidity: 15% to 95% relative humidity non-condensingStorage and transport temperature: -4°F to 140°F ( -20°C to +60°C)Storage and transport humidity: up to 95% relative humidity non-condensing
Gross dimensions Large: 16.34“ (H) x 3.70“ (W) x 1.77“ (D)   (415 mm (H) x 94 mm (W) x 45mm (D))Mask fully assembled with short tube assembly – no headgear.
Mask setting options For S9: Select ‘Pillows’For other devices: Select ‘SWIFT’, (if available), otherwise select ‘MIRAGE’ as the mask option.

Notes:

  • The mask system does not contain latex, PVC or DEHP materials.
  • The manufacturer reserves the right to change these specifications without notice.

StorageEnsure that the mask is thoroughly clean and dry before storing it for any length of time. Store the mask in a dry place out of direct sunlight.DisposalThis mask does not contain any hazardous substances and may be disposed of with your normal household refuse.

SymbolsCaution, consult accompanying documents; Lot number; Part number; Temperature limitation; Humidity limitation; Does not contain latex; Manufacturer; Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device; Keep away from rain; This way up; Fragile, handle with care.

Limited warranty

ResMed Pty Ltd (hereafter ’ResMed’) warrants that your ResMed mask system (including mask frame, cushion, headgear and tubing) shall be free from defects in material and workmanship from the date of purchase for the period of 90 days or in the case of disposable masks the maximum use period.This warranty is only available to the initial consumer. It is not transferable.If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components.This limited warranty does not cover: a) any damage caused as a result of improper use, abuse, modification or alteration of the product; b) repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs; and c) any damage or contamination due to cigarette, pipe, cigar or other smoke.Warranty is void on products sold, or resold, outside the region of original purchase.Warranty claims on defective products must be made by the initial consumer at the point of purchase.This warranty replaces all other expressed or implied warranties, including any implied warranty of merchantability or fitness for a particular purpose. Some regions or states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.This warranty gives you specific legal rights, and you may also have other rights which vary from region to region. For further information on your warranty rights, contact your local ResMed dealer or ResMed office.

Manufacturer:ResMed Pty Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia.See www.resmed.com for other ResMed locations worldwide.Swift FXProtected by patents: AU 785376, HK 1057714, EP 1314445, EP 1582230, JP 4354664,US 6581594, US 6823865, US 7159587. Other patents are pending.Protected by design registration: US D562976. Other designs are pending.Swift is a trademark of ResMed Pty Ltd and Swift is registered in U.S. Patent andTrademark Office.© 2020 ResMed.

Global leaders in sleep and respiratory medicine www.resmed.com

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by