NASAL PILLOWS SYSTEMThank you for choosing the Swift LT.Rx OnlyIntended UseThe Swift LT channels airflow noninvasively to a patient from a positive airway pressure device such as a continuous positive airway pressure (CPAP) or bilevel system.The Swift LT is:
to be used by adult patients (> 66 lb/30 kg) for whom positive airway pressure has been prescribed
intended for single-patient re-use in the home environment and multi-patient re-use in the hospital/institutional environment.
Using the Swift LTWhen using the Swift LT with ResMed flow generators that have mask setting options, if available select ‘SWIFT’; otherwise select ‘MIRAGE’ as the mask option.For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representativeNotes:
The Swift LT is not compatible for use with ResMed AutoSet CS™ 2 and VPAP™ Adapt SV devices.
SmartStop may not operate effectively when using Swift LT with some flow generators that have this feature.
If you experience nasal dryness or irritation, the use of a humidifier is recommended.
Swift LT mask components
Fitting your Swift LT
Using the Plastic Tube Retainer (Optional)
Disassembling your Swift LT
Cleaning your Swift LT in the home
Notes:
The nasal pillows system and headgear should be cleaned by handwashing.
The headgear may be washed without being disassembled.
WARNINGDo not use aromatic-based solutions or scented oils (eg, eucalyptus or essential oils), bleach, alcohol, or products that smell strongly (eg, citrus) to clean any of the system’s components. Residual vapors from these solutions can be inhaled if not rinsed thoroughly. They may also damage the system, causing cracks.
CAUTIONIf any visible deterioration of a system component is apparent (cracking, crazing, tears, etc.), the component should be discarded and replaced.Daily/After Each UseHandwash the separated mask components (excluding headgear) by gently rubbing in warm (approx. 86°F/30°C) water using mild soap for one minute. Rinse all components well with drinking quality water and allow them to air dry out of direct sunlight.WeeklyHandwash the headgear and tube retainer in warm (approx. 86°F/30°C) water using a mild soap. Rinse well and allow them to air dry out of direct sunlight.Reprocessing your Swift LT between PatientsOnly Sleep Lab Mask (SLM) variants of the mask are intended for multi-patient re-use. When using between patients, these masks must be reprocessed according to cleaning and disinfection instructions available on ResMed.com/ downloads/masks.StorageEnsure that your Swift LT is thoroughly clean and dry before storing it for any length of time. Store the mask in a cool dry place out of direct sunlight.DisposalThe Swift LT does not contain any hazardous substances and may be disposed of with your normal household refuse.
Reassembling your Swift LT
Reassembling the headgear
Troubleshooting
Pillows won’t seal properly, are uncomfortable, or cause red marks
Possible reason
Solution
Pillows may havebeen fitted incorrectly,
Carefully follow instructions in “Fitting your Swift LT”.Check headgear is not over-tightened.
incorrectly adjusted, orthe headgear is too tight.
Check ResMed logo on top of pillows is facingoutwards.
Inner wall position ofone/both pillows are incorrect.
Squeeze pillow sides to release the inner wall. Thethe correct position is shown in “Reassembling yourSwift LT”.
The pillows are the wrong size. Pillows may be dirty.
Talk to your clinician.Clean pillows according to instructions in “Cleaningyour Swift LT in the Home”.
Nasal pillows system is too noisy
System is assembledincorrectly.
Reassemble the Swift LT. Make sure the pillows arefully inserted into the frame.
Before using your Swift LT
WARNINGS
The vent holes must be kept clear.
The mask should not be used unless the CPAP system is turned on and operating properly.
Follow all precautions when using supplemental oxygen.
Oxygen flow must be turned off when the flow generator is not operating so that unused oxygen does not accumulate within the flow generator enclosure and create a risk of fire.
At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen concentration varies, depending on the pressure settings, patient breathing pattern, mask, point of application, and leak rate.
The technical specifications of the mask are provided for your clinician to check that they are compatible with the flow generator. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the flow generator function.
Discontinue using the Swift LT if you have ANY adverse reaction to the use of the mask, and consult your physician or sleep therapist.
As with all masks, some rebreathing may occur at low CPAP pressures.
Refer to your flow generator manual for details on settings and operational information.
Remove all packaging before using the mask.
Technical specifications
Note: The mask system does not contain latex, PVC, or DEHP materials.Pressure–Flow CurveNote: The mask contains passive venting that meets the requirements for protection against rebreathing as specified in ISO 17510-2. As a result of manufacturing variations, the vent flow rate may vary.
Dead SpaceInformation
Physical dead space is the empty volume of the mask to the end of the swivel. Using the large cushions this is 94 mL.
Standards
CE designation in accordance with EC directive 93/42/EEC, class IIa. ISO 14971, ISO 13485, ISO 10993-1, and ISO 17510-2.
TherapyPressure
4 to 20 cm H2 O.
Resistance
Drop in pressure measured (nominal) at 50 L/min: 0.6 cm H2 O and at 100 L/min: 2.0 cm H2 O.
Sound
DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with ISO 4871. The A-weighted sound power level of the mask is 25 dBA, with an uncertainty of 3 dBA. The A-weighted sound pressure level of the mask at a distance of 1 m is 17 dBA, with an uncertainty of 3 dBA.
EnvironmentalConditions
Operating temperature: +41°F to 104°F (+5°C to +40°C)Operating humidity: 15%–95% non-condensingStorage and transport temperature: -4°F to 140°F (-20°C to +60°C)Storage and transport humidity: up to 95% non-condensing.
GrossDimensions
380 mm (H) x 57 mm (W) x 62 mm (D). Mask fully assembled with short tube assembly – no headgear.
Note: The manufacturer reserves the right to change these specifications without notice.
Symbols
Caution, consult accompanying documents; LOT Lot number; REF Part number; Temperature limitation; Humidity limitation; Does not contain latex;Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device.
Limited warranty
ResMed Pty Ltd (hereafter ’ResMed’) warrants that your ResMed mask system (including mask frame, cushion, headgear, and tubing) shall be free from defects in material and workmanship from the date of purchase for the period of 90 days or in the case of disposable masks the maximum use period. This warranty is only available to the initial consumer. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components.This limited warranty does not cover: a) any damage caused as a result of improper use, abuse, modification, or alteration of the product; b) repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs; and c) any damage or contamination due to cigarette, pipe, cigar or other smoke.Warranty is void on products sold, or resold, outside the region of original purchase.Warranty claims on defective products must be made by the initial consumer at the point of purchase.This warranty replaces all other expressed or implied warranties, including any implied warranty of merchantability or fitness for a particular purpose. Some regions or states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation, or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.This warranty gives you specific legal rights, and you may also have other rights which vary from region to region. For further information on your warranty rights, contact your local ResMed dealer or ResMed office.