Installation and Operating Manual
Art-Nr. | 801041 801043 801044 | ||
Power (W) | 36 | ||
Input voltage Panel | 39-45VDC, 750mA | ||
Input voltage Driver | 220-240V, 50/60Hz, 170mA | ||
Luminous Flux (Im) | 3.600 | ||
Color temperature (K) | 4.000 I | 4.000 | I 3.000 |
LED lifetime (hr) | 30.000 | ||
Switch cycles | 15.000x | ||
Dimensions (mm) | 595 | x595 x 341 | 620 x620x 34 |
General safety instructions
Please read the operating instructions for the LED ceiling light before use. The operating instructions are part of the product. They contain important notes on the start-up and handling of the device. Always keep the enclosed operating instructions so as to be able to look up information. They must be enclosed when passing the device on to third parties.
Safety precautions
The user must observe the safety notes and warnings in order to maintain this status and to ensure safe operation. Please read the operating instructions before startup.Avoid contact with high temperatures or vibrations, this may cause damage to the ceiling light. Do not immerse the enclosure into water.Never attempt to open the device other than described in this manual. The LED ceiling light cannot be repaired; this part must be immediately disposed of in case of a defect. Ensure sufficient ventilation of the device. Never cover it during operation. Do not install in reach of children or animals.Any other use of the device than described above can damage the product or endanger the user due to e. g. short-circuits, fire or an electric shock. The entire product may not be modified or adapted. Don’t touch the ceiling light while in use or after use until it’s cooled down. The ceiling light must have an earthed connection for safe operation.These safety notes must be observed in all cases! Any warranty claim is void in the case of damages caused by the non-observance of these operating instructions. We are not liable for consequential damages or for damages to property or persons caused by non-observance of the safety notes and improper operation of the device.Safe operation is not possible anymore, if: – the LED ceiling light has visible damages, -the LED ceiling light does not work anymore
Note:
- The installation should be carried out by persons with electro technical knowledge and experience. Installation indoors only because the LED light is designed for protection class IP20 (protection against foreign objects from 12.5mm).
Notes on Disposal
The product is designated for separate collection at an appropriate collection point. Do not dispose of the product with household waste. For more information, contact the retailer or the local authority responsible for waste management.
Care
Before cleaning the unit, disconnect it, if necessary form other components; do not use aggressive cleaning agents.
Warranty
The unit has been carefully checked for defects. If nevertheless, you do have cause for complaint, please go back to the retailer where you have bought the product together with your proof of purchase.
Safety
General advice
- Read the manual carefully before use. Keep this manual for future reference.
- Only use the product for its intended purposes. Do not use the product for other purposes than described In the manual.
- Do not use this product if any part is damaged or defective. If the product is damaged or defective, replace the product immediately.
- This product Must not be used in the immediate vicinity of children without the supervision of an adult. Children must not be allowed to play with the device.
- Do not modify the product in any way.– Do not expose the product to water or moisture. (IP 20)– Do not immerse the product into water. (IP 44 —IP 66)
- Keep the product away from heat sources.
- Do not block the ventilation openings.
- Do not look directly into the light source of the lamp.
- Keep a minimum distance of >2 meters between the lamp and the surface being illuminated.
Electrical safety
- To reduce risk of electric shock, this product should only be opened by an authorized technician when service is required.
- Do not use the product if the cable or plug is damaged or defective. When damaged or defective, it must be replaced by the manufacturer or an authorized repair agent.
- Before use, always make sure that the voltage is the same as the voltage on the rating plate of the device.
- Make sure that the cable does not hang over the edge of a worktop and cannot be caught accidentally or tripped over
Warning
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similarly qualified person.
- Caution, risk of electric shock.
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire has to be destroyed.
Disclaimer
We reserve the right to make technical modifications. without notice. All logos, brands, and product names are trademarks or registered trademarks or their respective holders and are hereby recognized as such.We are not liable for damage arising from incorrect handling, improper use or wear or tear.Please visit us online For more information about our company and our products,
Documentation
The product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all member states of the European Union. The product complies with all applicable specifications and regulations in the country of sales.
Formal documentation is available upon request. The formal documentation includes, but is not limited to the Declaration of Conformity, the Material Safety Data Sheet and the product test report.CE declaration
This product complies with the following directives:ND: 2014/35/EU EMC: 2014/30/EU RoHS: 2011/65/EU Additionally, for Products with Radio transmitter units:RED: 2014/53/EU
The complete Declaration of Conformity Document (DOC) can be found at www.shada.nl
Installation Instructions
Panel lighting mounting pattern 1 — Ceiling inset 01
Panel lighting mounting pattern 5 — Hanging mounting 01/02
[xyz-ips snippet=”download-snippet”]