SPECIFICATION

This specification describes the requirements of 750W,850W,1000Wattsswitching power supply with an stretch ATX form-factor and EPS12V, +5Vstandby voltage, remote on/off control, full range line input capability andforced air cooling characteristics.

AC INPUT
AC input requirements

The input voltage, current, and frequency requirements for continuous operation are stated below.

Table 1 AC Input Line Requirements.

Parameter Min. Nom. Max.

Unit

Vin( Full range )

90 100—240 264

VACrms

Vin Frequency

47 60—50 63

Hz

Iin(750W)

10—5

Arms

Iin(850W)

11—5.5

Arms

Iin(1000W) 12—6 Arms

Power factor correction (PF)>0.90 at full load.

The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and over the specified temperature range (Top). The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device).

DC OUTPUT

DC voltage regulation

Parameter

Range Min Nom. Max

Unit

+3.3V

+/-3% +3.20 +3.3 +3.40

Volts

+5V

+/-3% +4.85 +5.0 +5.15

Volts

+12V

+/-3% +11.64 +12.0 +12.36

Volts

-12V

+/-10% -13.20 -12.0 -10.80

Volts

+5VSB

+/-5% +4.85 +5.0 +5.25

Volts

Load ranges

750W(ST75F-P)Load Range

Parameter

Min Nom Max Peak

Unit

+3.3V

0 20

Amps

+5V

0.5 25

Amps

+12V

0.1 60 66

Amps

-12V

0 0.3

Amps

+5VSB

0.1 3.5

Amps

  1. Maximum continuous total DC output power should not exceed 750W.
  2. Maximum continuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 150W.
  3. Maximum peak total DC output power should not exceed 800 W.
  4. Peak power and current loading shall be supported for a minimum of 12 second.
  5. Peak current for the combined 12V outputs shall be 66A.
  6. When +12V is load to 28A , -12V minimum load is 0.02A.

850W(ST85F-P)Load Range

Parameter Min Nom Max Peak

Unit

+3.3V

0 20

Amps

+5V

0.5 25

Amps

+12V

0.1 67 72

Amps

-12V

0 0.3

Amps

+5VSB

0.1 3.5

Amps

  1. Maximum continuous total DC output power should not exceed 850W.
  2. Maximum continuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 180W.
  3. Maximum peak total DC output power should not exceed 950 W.
  4. Peak power and current loading shall be supported for a minimum of 12 second.
  5. Peak current for the combined 12V outputs shall be 72A.
  6. When +12V is load to 28A , -12V minimum load is 0.02A.

1000W(ST1000-P)Load Range

Parameter

Min Nom Max Peak

Unit

+3.3V

0 30

Amps

+5V

0.5 30

Amps

+12V

0.1 80 85

Amps

-12V

0 0.3

Amps

+5VSB

0.1 3.5

Amps

  1. Maximum continuous total DC output power should not exceed 1000W.
  2. Maximum continuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 180W.
  3. Maximum peak total DC output power should not exceed 1100 W.
  4. Peak power and current loading shall be supported for a minimum of 12 second.
  5. Peak current for the combined 12V outputs shall be 85A.
  6. When +12V is load to 28A , -12V minimum load is 0.02A.
Output Ripple

Ripple regulation

Parameter

Ripple & Noise

Unit

+3.3V

50

mVp-p

+5V

50

mVp-p

+12V

120

mVp-p

-12V

120

mVp-p

+5VSB

50

mVp-p

DefinitionThe ripple voltage of the outputs shall be measured at the pins of the outputconnector when terminated in the load impedance specified in figure 1. Rippleand noise are measured at the connectors with a 0.1uF ceramic capacitor anda 10uF electrolytic capacitor to simulate system loading. Ripple shall be measured under any condition of line voltage, output load, line frequency, operation temperature.

Ripple voltage test circuit

Overshoot

Any overshoot at turn on or turn off shall be less 10% of the norminal voltage value, all outputs shall be within the regulation limit of section 2.0 before issuing the power good signal of section 5.0.

Efficiency

Power supply efficiency typical 85% at 115Vac normal voltage.

Remote ON/OFF control

When the logic level “PS-ON” is low, the DC outputs are to be enabled.When the logic level is high or open collector, the DC outputs are to be disabled.

PROTECTION

Over Current Protection

The power supply shall have current limit to prevent the +3.3V,+5V,and +12Voutputs from exceeding the values shown in the following Table. If the currentlimits are exceeded the power supply shall shutdown and latch off.

750W(ST75F-P)

Voltage Over Current Limit (Iout limit)
+12V 66A minimum; 90A maximum
+5V 30A minimum; 50A maximum
+3.3V 30A minimum; 50A maximum

850W(ST85F-P)

Voltage Over Current Limit (Iout limit)
+12V 70A minimum; 100A maximum
+5V 30A minimum; 50A maximum
+3.3V 30A minimum; 50A maximum

1000W(ST1000-P)

Voltage Over Current Limit (Iout limit)
+12V 88A minimum; 130A maximum
+5V 35A minimum; 50A maximum
+3.3V 35A minimum; 50A maximum
Over Temperature Protection

The power supply will be protected against over temperature conditions causedby loss of fan cooling or excessive ambient temperature. In an OTP condition the PSU will shutdown. When the power supply temperature drops to within specified limits, the power supply shall restore power automatically. The OTP circuit must have built in hysteresis such that the power supply will not oscillate on and off due to temperature recovering condition.

Over-Power Protection

The power supply will be shutdown and latch off when output power within105~150% of rated DC output.Note: Assurance machine can work at low voltage, full load won’t damage machine.

Under Voltage Protection

In an under voltage fault occurs, the supply will latch all DC outputs into a shutdown state when +12V,+5V & +3.3V outputs under 85% of it’s maximum value.

Over voltage protection

The over voltage sense circuitry and reference shall reside in packages that areseparate and distinct from the regulator control circuity and reference. No single point fault shall be able to cause a sustained over voltage condition on any or all outputs. The supply shall provide latch-mode over voltage protection as defined in Table.

Output Minimum Nominal Maximum Unit
+12VDC 13.3 15.0 15.6 Volts
+5VDC 5.70 6.30 7.00 Volts
+3.3VDC 3.90 4.20 4.50 Volts
Short circuit

An output short circuit is defined as any output impedance of less than 0.1 ohms. The power supply shall shut down and latch off for shorting the +3.3 VDC,+5 VDC or +12 VDC rails to return or any other rail. Shorts between main output rails and +5VSB shall not cause any damage to the power supply.The power supply shall either shut down and latch off or fold back for shorting the negative rails.+5VSB must be capable of being shorted indefinitely, but when the short is removed, the power supply shall recover automatically or by cycling PS_ON#. The power supply shall be capable of withstanding a continuous short-circuit to the output without damage or overstress to the unit

No load operation

No damage or hazardous condition should occur with all the DC output connectors disconnected from the load. The power supply may latch into the shutdown state.

TIMING

Signal timing drawing

Figure 2. is a reference for signal timing for main power connector signals and rails.

Figure 2. PS-OK Timing Sequence

  1. T3: Power good signal turn on delay time (100ms~500ms)
  2. T4: Power good signal turn off delay time (1ms min)
  3. T2: Rise time (0.1~70ms)
  4. T6: Hold up time (17ms min) Tested at 75% of maximum load and over100-240VAC input.
Hold up time

When the power loss its input power, it shall maintain 17ms in regulation limit at normal input voltage. (AC:115V/60Hz or 230V/50Hz,at 75% of maximum load)

ENVIRONMENT

Operation
Temperature 0 to 40 C
Relative Humidity 10 to 90%, non-condensing
Shipping and Storage
Temperature -20 to 60 C
Relative Humidity 5 to 95%, non-condensing
Altitude
Operating 10,000FT max
Storage 50,000FT max

MTBF

MTBF (mean time between failures) calculation

The demonstrated MTBF shall be 100,000 hours of continuous operation at 25 C, full load, and nominal line. The MTBF of the power supply be calculated in accordance with MIL-HDBK-217F. The DC FAN is not included.

MECHANICAL REQUIREMENTS

Physical Dimension

150 mm (W) × 86 mm (H) × 160mm (D)

Connectors

M/B 24PIN connector

Signal Pin Pin Signal
Orange +3.3V 13 1 +3.3V Orange
Orange +3.3Vsense 13
Blue -12VDC 14 2 +3.3V Orange
Black COM 15 3 COM Black
Green PS-ON 16 4 +5VDC Red
Black COM 17 5 COM Black
Black COM 18 6 +5VDC Red
Black COM 19 7 COM Black
White N/C 20 8 PWRGOOD Grey
Red +5VDC 21 9 +5Vsb Purple
Red +5VDC 22 10 +12V Yellow
Red +5Vsense 22
Red +5VDC 23 11 +12V Yellow
Black COM 24 12 +3.3V Orange

EPS 12V 8PIN Connector

Signal Pin Pin Signal
Yellow +12V 5 1 COM Black
Yellow +12V 6 2 COM Black
Yellow +12V 7 3 COM Black
Yellow +12V 8 4 COM Black

ATX 12V 4PIN (4+4PIN EPS 12V in split mode)

Signal Pin Pin Signal
Black GND 1 3 12V Yellow
Black GND 2 4 12V Yellow

4PIN peripheral connector (HDD)      4PIN floppy connector (FDD)

Signal Pin Pin Signal
Yellow +12V 1 1 +5VDC Red
Black COM 2 2 COM Black
Black COM 3 3 COM Black
Red +5VDC 4 4 +12V Yellow

SATA connector

Signal Pin
Orange +3.3V 5
Black COM 4
Red +5V 3
Black COM 2
Yellow +12V 1

8PIN PCI Express connector

Signal Pin Pin Signal
Yellow +12V 1 5 COM Black
Yellow +12V 2 6 COM Black
Yellow +12V 3 7 COM Black
Black sense1 COM 4 8 COM Black

6PIN PCI Express connector

Signal Pin Pin Signal
Yellow +12V 1 4 COM Black
Yellow +12V 2 5 COM Black
Yellow +12V 3 6 COM Black

SilverStone Technology Co. Ltd.www.silverstone.comissue date: September, 2009NO. G11210670