Standalone Keypad Access Control User Manual

Standalone Keypad Access Control User Manual

 

Packing List

Name

Quantity

Remarks

Keypad

1

 
User manual

1

 
Screw driver

1

Φ 20mm×60mm,Special for keypad
Rubber plug

2

Φ 6mm×30 mm, used for fixing
Self tapping screws

2

Φ 4mm×28 mm, used for fixing
Star screws

1

Φ 3mm×6mm, used for fixing

Please ensure that all the above contents are correct. If any are missing please notify the supplier of the unit.

Quick Reference Programming Guide

To enter the programming mode   999999 is the default factory master code
To exit from the programming mode
Note that to undertake the following programming the master user must be logged in
To change the master code The master code can be 6 to 8 digits
To add a PIN user. The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. can be added continuously without exiting programming mode
To add a card user Cards can be added continuously without exiting programming mode
To delete a PIN or a card user. Users can be deleted continuously without exiting programming mode
To unlock the door for a PIN user Enter the  then press 
To unlock the door for a card user Present the card

Description

The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish. The electronics are fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000 users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM cards,13.56MHz Mifare cards. The unit has many extra features including lock output current short circuit protection, Wiegand output , and a backlit keypad. These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons.

Features

  • Waterproof, conforms to IP68
  • Strong Zinc Alloy Electroplated anti-vandal case
  • Full programming from the keypad
  • 2000 uses, supports Card, PIN, Card + PIN
  • Can be used as a stand alone keypad
  • Backlight keys
  • Wiegand 26 input for connection to external reader
  • Wiegand 26 output for connection to a controller
  • Adjustable Door Output time, Alarm time, Door Open time
  • Very low power consumption (30mA)
  • Fast operating speed, <20ms with 2000 users
  • Lock output current short circuit protection
  • Easy to install and program
  • Built in light dependent resistor (LDR) for anti tamper Built in buzzer
  • Red, Yellow and Green LEDS display the working status

Specifications

Operating Voltage DC 12V±10%
User Capacity 2000
Card Reading Distance 3-6 cm
Active Current <60mA
Idle Current 25±5 mA
Lock Output Load Max 3A
Alarm Output Load Max 20A
Operating Temperature -45℃~60℃
Operating Humidity 10%- 90% RH
Waterproof Conforms to IP68
Adjustable Door Relay time 0 -99 seconds
Adjustable Alarm Time 0- 3 minutes
Wiegand Interface Wiegand 26 bit
Wiring Connections Electric Lock, Exit Button, External Alarm,External reader

Installation

  • Remove the back cover from the keypad using the supplied special screw driver
  • Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
  • Put the supplied rubber bungs to into the two holes
  • Fix the back cover firmly on the wall with 2 Self tapping screws
  • Thread the cable through the cable hole
  • Attach the keypad to the back cover.

Wiring

Color Function Description
Pink BELL_A Doorbell button one end
Pale blue BELL_B Doorbell button to the other end
Green D0 WG output D0
White D1 WG output D1
Grey ALARM Alarm negative(alarm positive connected 12 V+)
Yellow OPEN Exit button one end(the other end connected GND)
Brown D_IN Magnetic switch one end(the other end connected GND)
Red 12V+ 12V + DC Regulated Power Input
Black GND 12V – DC Regulated Power Input
Blue NO Relay normally-on end(Connect positive electric lock “-“)
Purple COM Relay Public end, connect GND
Orange NC Relay Closed end(connect negative electric lock “-“)

Common power supply diagram:

Special power supply diagram:

To Reset to Factory Default

  • a. Disconnect power from the unit
  • b. Press and hold # key whilst powering the unit back up
  • c. On hearing two “Di” release # key, system is now back factory settings

Please note only installer data is restored, user data will not be affected

Anti Tamper Alarm

The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate.

Sound and Light indication

Operation Status

Red Light Green Light Yellow Light

Buzzer

Power on Bright Di
Stand by Bright
Press keypad Di
Operation successful Bright Di
Operation failed DiDiDi
Enter into programming mode Bright  
In the programming mode Bright Di
Exit from the programming Bright Di

Detailed Programming Guide

 

11.1    User Settings

To enter the programming mode

999999 is the default factory master code

To exit from the programming mode
Note that to undertake the following programming the master user must be logged in
To change the master code The master code can be 6 to 8 digits long
Setting the working mode:

Set valid card only users

Set valid card and PIN users Set valid card or PIN users

 

 

Entry is by card only

  Entry is by card and PIN together

Entry is by either card or PIN (default)

To add a user in either card or PIN mode, i.e. in the  mode. (Default setting)
To add a Pin user

The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode as follows:

To delete a PIN user Users can be deleted continuously without exiting programming mode
To change the PIN of a PIN user

(This    step    must    be    done    out of programming mode)

To add a card user (Method 1)

This is the fastest way to enter cards, user ID number auto generation.

Cards can be added continuously without exiting programming mode

To add a card user (Method 2)

 

This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card.

User can be added continuously without exiting programming mode

To add a card user (Method 3)

 

Card number is the last 8 digits printed

on the back of the card, user ID number auto generation

User can be added continuously without exiting programming mode

To add a card user (Method 4)

 

In this method a User ID is allocated to a card number. Only one user ID can be allocated to the card number

User  can    be        added   continuously     without      exiting programming mode

To delete a card user by card. Note users can be deleted continuously without exiting programming mode
To delete a card user by user ID. This option can be used when a user has lost their card
To delete a card user by card number.

 

This option can be used when the user want to make the change but the card has lost

Note users can be deleted continuously without exiting programming mode

To add a card and PIN user in card and PIN mode
To Add a card and Pin user

(The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved.)

Add the card as for a card user

Press    to exit from the programming mode

Then allocate the card a PIN as follows:

To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves
To change a PIN in card and PIN mode (Method 2) Note that this is done outside
programming mode so the user can undertake this themselves  
To delete a Card and PIN user just delete the card
To add a card user in card mode
To Add and Delete a card user The operating is the same as adding and deleting a card user in

To delete All users
To delete ALL users. Note that this is a

dangerous option so use with care

To unlock the door
For a PIN user Enter the then press
For a card User
For a card and PIN user then enter

Door Settings

Relay Output Delay Time
To set door relay strike time

0-99 is to set the door relay time 0-99 seconds

Door Open Detection

Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically.

Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is forced open, or if the door is opened after 20 seconds, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the

Default being 1 minute.

To disable door open detection. (Factory default)
To enable door open detection
Alarm output time
To set the alarm output time (0-3 minutes) Factory default is 1 minute
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside buzzer will operate for 10 minutes, depending on the option selected below.
Normal status: No keypad lockout or alarm (factory default)      (Factory default setting)
Keypad Lockout   
Alarm and inside buzzer operate
To remove the alarm
To reset the Door Forced Open warning
To reset the Door Open Too Long warning Close the door or              

The unit operating as a Wiegand Output Reader

In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input.

 

[xyz-ips snippet=”download-snippet”]