StarTech RK3236BKF 32U Knock-Down Server Rack Cabinet with Casters User Manual
Use of Trademarks, Registered Trademarks, and other Protected Names and Symbols
This manual may make reference to trademarks, registered trademarks, and other protected names and/or symbols of third-party companies not related in any way to StarTech.com. Where they occur these references are for illustrative purposes only and do not represent an endorsement of a product or service by StarTech.com, or an endorsement of the product(s) to which this manual applies by the third-party company in question. Regardless of any direct acknowledgement elsewhere in the body of this document, StarTech.com hereby acknowledges that all trademarks, registered trademarks, service marks, and other protected names and/or symbols contained in this manual and related documents are the property of their respective holders.
Warning Statements
- Make sure that you assemble this product according to the instructions.
- Do not exceed the weight capacity of this product. Overloading this product might result in injury or property damage. This product can support the following weight: Stationary = 1763.7 lb. (800 kg) Rolling = 352.7 lb. (160 kg).
- This product is intended for indoor use only and should not be used outdoors.
- This enclosure is extremely heavy. Never attempt to move or lift this enclosure without assistance.
- Tipping hazard! Unless properly stabilized and handled correctly, this enclosure can be prone to tipping. Always exercise extreme caution when handling the enclosure and loading and unloading equipment. Failure to do so can result in serious personal injury and/or equipment damage.
- Do not place any items on this enclosure and do not stack the enclosure on top of another enclosure.
- Keep liquid away from this enclosure.
- Make sure that you install the enclosure in an area that can handle the combined weight of the enclosure and the equipment that you intend to place inside of the enclosure.
- This product requires an earth ground connection. Do not use this product without an earth ground connection.
Safety Statements
Safety Measures
- Cables (including power and charging cables) should be placed and routed to avoid creating electric, tripping or safety hazards.
Product Diagram Front View
1 | Top Panel | 6 | Bottom Panel |
2 | Plastic Corner Caps | 7 | Casters |
3 | Center Beam | 8 | Side Panel |
4 | Front Door | 9 | Rear Door |
5 | Leveling Feet |
Product Dimensions
Side
Product InformationPackage Contents
- Side Panels x 2
- Center Beams x 4
- Bottom Panels w/ Cable Management Slot x 2
- Bottom Panel x 1 Front Door x 1
- Rear Door x 1
- Plastic Corner Caps x 8
- M8 x 20 mm Hex Screws x 8
- M8 Spring Washers x 8
- M4 x 10 mm Flat Head Screws x 8
- M6 x 12 mm Hex Screws x 4
- M5 x 12 mm Screws x 6
- M6 Hex Key x 1
- M8 Hex Key x 1
- M6 x 12 mm Phillips Screws x 40
- M6 Cage Nuts x 40
- M6 Plastic Cap Washers x 40
- Casters x 2
- Caster w/Brakes x 2
- M6 x 10 mm Phillips Bolts x 16
- Leveling Feet x 4
- Front/Rear Door Keys x 2
- Side Panel Keys x 2
- Phillips Head Screwdriver x 1
- Door Hinge Pin x 2
Requirements
- 14 mm Wrench x 1
- Grounding Wires x 2
- (Optional) Cage Nut Tool x 1
Assembling the Server Rack
- Align the Screw Hole located at the corner of the Side Panel with the Screw Hole at the end of a Center Beam. Ensure that the Lip on the Center Beam lines up with the Lip onthe inner side of the Side Panel.
- Slide an M8 Spring Washer over a M8 x 20 mm Hex Screw.
- Insert the M8 x 20 mm Hex Screw through the Screw Hole in the Side Panel and into the Screw Hole on the Center Beam.
- Using the M8 Hex Key tighten the M8 x 20 mm Hex Screw, being careful not to over-tighten.
- Repeat steps 1 – 4 for the remaining Center Beams and to install the other Side Panel. Ensure that the Side Panels are orientated similarly.
- Orientate the Server Rack vertically so that the Caster Mounting Holes are accessible.
- Align the Mounting Holes on the Casters with the Mounting Holes at the corner of the Server Rack Frame.
- Insert four M6 x 10 mm Screws through the Mounting Holes on the Caster and into the Mounting Holes in the Server Rack Frame.
- Using a Phillips Head Screwdriver, tighten the M6 x 10 mm Screws, being careful not to over-tighten.
- Repeat steps 7 – 9 to install the other Caster and Casters with Brakes. Ensure that the set of Casters with Brakes are placed at the required end of the Server Rack Frame.
- Insert the Leveling Feet into the Pre-Threaded Holes on the bottom of the Server Rack Frame.
- Using a 14 mm Wrench, adjust the Leveling Feet so that the four Leveling Feet are all approximately the same height and are shorter than the height of the Casters.
- Align the Screw Hole in the Plastic Corner Caps (x 4) with the Screw Hole on each of the corners on the Server Rack.
- Insert a M4 x 10 mm Flat Head Screw through the Screw Holes in the Plastic Corner Cap and into the Screw Hole on the Server Rack. Using a Phillips Head Screwdriver, tighten the M4 x 10 mm Flat Head Screws, being careful not to over-tighten.
- Orient the Server Rack Frame onto the Casters.
- Repeat steps 13 – 14 to install the other four Plastic Corner Caps.
- Rest the Bottom Plate w/ Cable Management Slot at the bottom of the Server Rack Frame (at either end) and align with the Screw Holes in the frame.
- Insert two M6 x 12 mm Phillips Screws through the Screw Holes in the Bottom Plate w/ Cable Management Slot and into the Screw Holes on the interior of the Side Panel.
- Using a Phillips Head Screwdriver, tighten the M6 x 12 mm Phillips Screws, being careful not to over-tighten.
- Repeat steps 17 – 19 to install the other Bottom Plate w/ Cable Management Slot and then the Middle Bottom Plate (position accordingly).
- On the top of the Server Rack, align the Screw Holes in the four corners on the Top Panel with the Screw Holes in the four corners on the top of the Server Rack Frame.Note: The Top Panel should fit tightly against the corner piece of the Top of the Server Rack.
- Insert a M6 x 12 mm Hex Screw through the Screw Hole in the Top Panel and into the Screw Hole on the Server Rack Frame.
- Using the M6 Hex Key, tighten the M6 x 12 mm Hex Screw, being careful not to over-tighten.
- Repeat steps 22 – 23 for the remaining corners.
- Facing the front/rear of the Server Rack Frame, insert a Door Hinge Pin into the Hinge Pin Hole located in the bottom right corner of the Server Rack Frame.
- Angle the bottom corner of the Front Door towards the Door Hinge Pin.
- Insert the Door Hinge Pin into the bottom Hinge Pin Hole on the Front Door. The required corner is located on the side opposite to the lock which does not have the Spring Loaded Pin.
- In the top corner on the Front Door, pull the Spring- Loaded Hinge Pin down.
- While holding down the Spring-Loaded Hinge Pin, angle the top corner of the Front Door towards the top corner of the Server Rack, aligning the Spring-Loaded Hinge Pin with the Hinge Pin Hole.
- 30. Release the Spring-Loaded Hinge Pin into the Hinge Pin Hole.
- Repeat steps 25 – 30 to install the Rear Door.
Stabilizing the Server Rack
Prior to the installation of any rack equipment, the Server Rack must be properly stabilized using the Leveling Feet which increases the size of the Base (for improved stability) and helpsto prevent any Server Rack movement. The Server Rack floor should be a flat, level surface which can support the combined weight of the Server Rack and installed rack equipment.
- Using the 14 mm Wrench, lower the Leveling Feet located next to each Caster) by turning each one clockwise until the base of the Leveling Feet are tightly pressed against thesurface and supporting the weight of the Server Rack.
Grounding the Enclosure
Note: This product must be grounded. Do not use this product without an earth ground connection.
- Attach Grounding Wires to the Server Rack at the labeled Grounding Studs located on the Front/Rear Doors and Side Panels.
- Route the primary Grounding Wire out from the bottom or top of the Server.
Installing Equipment
Note: When you load equipment into this product, load the heaviest equipment in the bottom units first. Continue loading equipment in a descending order of weight, so thatthe lighter equipment is installed in the upper sections of the enclosure and the heavier items are on the bottom.
- Decide where in the Server Rack you want to install the equipment and insert the M6 Cage Nuts in the Mounting Rails.
- Line up the Mounting Holes on the equipment with the M6 Cage Nuts.
- Insert the Screws through the Mounting Holes on the equipment and into the M6 Cage Nuts.
- Using a Phillips Head Screwdriver tighten the Screws, being careful not to over-tighten.
Adjusting the Mounting Rails
- Each Mounting Rail has four M6 Screws securing the Mounting Rail to two Depth Adjustment Rails. Two M6 Screws are located at the top and two M6 Screws are located at the bottom of a Mounting Rail.
- Using a Phillips Head Screwdriver, remove the four M6 Screws and to detach the Mounting Rail.
- Remove the Cage Nuts from the Depth Adjustment Rails by pinching the two Prongs on the Cage Nut inwards.Note: Use a Cage Nut Tool (sold separately) if you are having trouble removing the Cage Nuts from the Depth Adjustment Rails.
- Reposition the Mounting Rail along the Depth Adjustment Rails to the desired mounting depth and determine the new Cage Nut mounting locations.Notes: The distance between each of the Mounting Rail Adjustment Hole is 7/8 inch.
- Insert the Cage Nuts into the required Square Mounting Holes on the Depth Adjustment Rails. To install, insert one side of the Cage Nut into the Square Mounting Hole andpush the other side into the Square Mounting Hole, until it locks into place.Note: Use a Cage Nut Tool (sold separately) if you are having issues installing the Cages Nuts into the Depth Adjustment Rails.
- Reposition the Mounting Rail again along the Depth Adjustment Rails and insert the removed M6 Screws through the Mounting Rail and into the Cage Nuts in theDepth Adjustment Rails.
- Using a Phillips Head Screwdriver to tighten the M6 Screws. Be careful not to over-tighten the M6 Screws.
Warranty Information
This product is backed by a lifetime warranty. For further information on product warranty terms and conditions, please refer to www.startech.com/warranty.
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their officers, directors, employees or agents) for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of profits, loss of business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the product.Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the limitations or exclusions contained in this statement may not apply to you.
Hard-to-find made easy. At StarTech.com, that isn’t a slogan. It’s a promise.
the latest technology to legacy products — and all the parts that bridge the old and new — we can help you find the parts that connect your solutions.We make it easy to locate the parts, and we quickly deliver them wherever they need to go. Just talk to one of our tech advisors or visit our website. You’ll be connected to the products you need in no time. Visit www.startech.com for complete information on all StarTech.com products and to access exclusive resources and time-saving tools. StarTech.com is an ISO 9001 Registered manufacturer of connectivity and technology parts. StarTech.com was founded in 1985 and has operations in theUnited States, Canada, the United Kingdom and Taiwan servicing a worldwide market.
Reviews
Share your experiences using StarTech.com products, including product applications and setup, what you love about the products, and areas for improvement.
StarTech.com Ltd. 45 Artisans Crescent London, Ontario N5V 5E9 Canada StarTech.com Ltd.Unit B, Pinnacle 15 Gowerton Road Brackmills, Northampton NN4 7BW United Kingdom StarTech.com LLP 4490 South Hamilton Road Groveport, Ohio 43125U.S.A. StarTech.com Ltd. Siriusdreef 17-27 2132 WT Hoofddorp The Netherlands.
Read More About This Manual & Download PDF:
References
StarTech.com Support
StarTech.com Warranty Policy
当社は、接続、変換、拡張、分離、切換えを行うIT & A / Vプロフェッショナルのためのパーツを製造しています | 日本
32U Server Rack Cabinet Adjustable Depth – Server-Racks
StarTech.com | IT Pro\’s Trusted Source for Connectivity Accessories
StarTech.com conçoit et fabrique une vaste sélection de pièces d’ordinateur, de câbles, de commutateur KVM, de racks… | France
Pezzi per computer, cavi, switch KVM, server rack e soluzioni per reti | Italia
Unsere Produkte dienen IT- und A/V-Profis zum Verbinden, Konvertieren, Erweitern, Splitten und Switchen | Deutschland
StarTech.com ontwerpt en produceert een enorme selectie computeronderdelen, kabels, KVM-switches, serverracks en… | Nederland
StarTech.com | IT Pro\’s Trusted Source for Connectivity Accessories
[xyz-ips snippet=”download-snippet”]