Superlux ECM999 Condenser Measurement Microphone Instructions

ECM999CONDENSER MEASUREMENTMICROPHONE

Description

The ECM999 is an Omni-directional microphone for free-field measurement with a built-in highly reliable circuit,  1/4″ pre-polarized condenser capsule, high stability, low dis- portion, and less noise in performance. Its excellent flat frequency response makes it an ideal candidate for sonic analysis systems and for special recording as well.

Features

  • Sturdy metal construction, solemn black finish.
  • Very flat response, excellent electro-acoustic characteristics.
  • Ideal for room sonic analysis systems, measurement, testing, and recording.
  • Powered by phantom power 12 – 52 V.
  • Standard 1/2″ measurement diameter.

ECM999 Frequency Response (Omni)

Included

www.superlux.com.tw

Specifications

Type Back electretØ6 mm (Ø0.24″)
Polar Pattern Omni
Frequency Response 20 – 20,000 Hz
Sensitivity -37 dB/Pa (14 mV)
Output Impedance 200 Ω
Min. Load Impedance 1,000 Ω
S/N Ratio 70 dB
Equivalent Output Noise 24 dB
Max. SPL 132 dB
Dynamic Range 108 dB
Power Requirements 12 – 52 V, 2 mA
Finish Connector Dimensions  Black
Connector XLR3M
Dimensions Ø21 × 192 mm(Ø0.83″ × 7.56″)
Net Weight 140 g (4.9 oz.)

This information sheet contains important information for the safe use of the product. Read and follow the safety and handling instructions given here. Please keep this information sheet for future reference. If you pass on the product described overleaf, please enclose this information sheet.

Safety instructions

Intended useThis device converts acoustic signals in electrical signals. Any other use or use under the conditions excluded here is considered improper and can lead to personal injury or property damage. Neither the manufacturer nor the distributor is liable for damage resulting from improper use.Choking hazard for childrenMake sure that plastic sleeves, packaging, etc. cannot get into the reach of babies and small children. Do not allow children to use electrical devices unsupervised. They could loosen parts of the product,  then swallow them and choke on them!Place of operationThe device must not be used

  • at particularly high temperatures or humidity
  • in particularly dusty or polluted places
  • in places where it can be exposed to moisture

General handlingTo prevent damage, never use force when handling the product. Never immerse the product in liquids. Just wipe it with a clean, dry cloth. Never use liquid cleaners such as benzene, thinner, or flammable detergents to clean the product.

Disposal

Old devicesDevices with this label are subject to the current EU directive on waste electrical and electronic equipment  (WEEE directive) and may not be disposed of with household waste, but only via a suitable disposal company. Ask your local authority or your specialist dealer about your options for proper disposal.PackagingsEnvironmentally friendly materials have been selected for the packaging and are to be recycled. Do not just throw away plastic sleeves, packaging, etc., but recycle them. If necessary, note the instructions and labels on the packaging.

www.superlux.com.tw