ThermoPro TP-63B/TP63C Humidity and Temperature Monitor Instruction Manual

Wireless Indoor/Outdoor Humidity and Temperature MonitorModel: TP-63B/TP63CV20201106Instruction Manual

Introduction

Congratulations on your purchase of the wireless indoor/ outdoor humidity and temperature monitor. You will now be able to know the outdoor/indoor temperature and humidity while sitting inside.

Components

  1. One base station unit (Receiver).
  2. One remote sensor (Transmitter).

Indoor Base Station (Receiver) Features

1. Large LCD display2. Remote low Battery Icon3. Outdoor temperature4. Base Station Low Battery Icon5. Indoor temperature6. Outdoor humidity7. Indoor humidity8. Backlight Touch Button 9. Wail Mount10. Magnet11. Stand12. Battery compartment13. CHANNEL SYNC14 .°F/°C ALL-TIME/2415. MAX/MIN CLEAR
  1. LCD display: Displays the current outdoor humidity/ temperature and indoor humidity/temperature.
  2. Battery Compartment: Holds 2 AAA batteries to power the unit.
  3. Tabletop, wall-mountable and magnet-mountable design.
  4. Indoor Temperature range: -4 °F-158°F(-20°C-70°C).
  5. Humidity range: 10% — 99%.
  6. Temperature display unit: °C and °F selectable.
  7. Temperature Resolution: 0.1 °C/°F.
  8. Humidity Resolution:1%.
  9. Low battery indication.

Buttons

: Touch once to turn on/off the backlight. If the button is not pressed in 15 seconds, the backlight will automatically turn off.MAX/MIN/CLEAR: Press once to display the maximum or minimum temperature and humidity; Press and hold to clear the history data.°F/°C/All-time/24: Press to select the temperature display in °C or °F; After pressing the MAX/MIN button, and the display shows the maximum or minimum temperature and humidity. Touch this button once to set the maximum and minimum data recording time interval between ALL TIME or 24 hours.

Note: Both ALL TIME and 24 hours represent the last time after you manually cleared the history data or installed a new battery.

CHANNEL/SYNC: Press to switch between the temperature readings from up to 3 outdoor remote sensors; Press and hold this button to enter the synchronization mode.

Temperature & Humidity Trend

  1. indicates the temperature & humidity are in an upward trend.
  2. → indicates the temperature & humidity is in a no change trend.
  3. indicates the temperature & humidity is in a downward trend.

Outdoor Remote Sensor (Transmitter) Features

  1. LED
  2. Reset
  3. Wall Mount
  4. Charging Socket
  5. ON/OFF
  6. Channel Selector
  7. Humidity Sensor
  8. Temperature Sensor
  1.  Built-in rechargeable lithium battery: Type 18650.
  2. Rain-proof and wall-mount design.
  3. Outdoor Temperature range: -31°F-158°F(-35°C-70°C).
  4. Humidity range: 10% – 99%. (ON: Flash 1 time, of Flash 3 times)

To access the CHANNEL SELECTOR and RESET buttons, you need to unscrew the cover as per Fig.

CHANNEL Selector (1,2,3): Slide to set Channel 1,2 or 3.RESET: Press once to reset the remote sensor.

: Press and hold for 2 seconds to turn ON/OFF the unit.( ON: Flash 1 Time, OFF : Flash 3 Times)

Synchronize Remote Sensors with The Base Station

  1. Bring the remote sensor near the base station;
  2. Once the batteries are installed into the base station, the RF indicator will flash for 3 minutes, indicating that the base station is in synchronization mode and is waiting for remote sensors to be registered.
  3. Set the CHANNEL selector on the back of the remote sensor unit to position 1 or 2 or 3. The unit is preset on Channel 1 and you can always leave it unchanged unless you have purchased more than 1 remote sensor.
  4. Press and hold the ON/OFF button on the back of the remote sensor for 2 seconds to turn on the remote sensor. If done correctly, the temperature/humidity of the remote sensor will appear on the base station.
  5. IF the RF indicator no longer flashes and the remote sensor temperature is not displayed on the base station. Press and hold the CHANNEL/SYNC button on the back of the base station for 3-4 seconds until the RF indicator flashes again to set it back in synchronization mode;
  6. If you have additional remote sensors, repeat the above steps to synchronize the additional remote sensors. Please note the additional sensors should be set to a different channel.
  7. If you have registered more than one sensor, press the CHANNEL/SYNC button on the base station to select the remote channel you want to be displayed permanently on the base station. If you wish to cycle through all the channels, press the CHANNEL/SYNC button until you observe a circular arrow on the base station LCD display, the unit will auto-scroll, changing from channel to channel every 5 seconds. Press the CHANNEL button until you observe the circular arrow disappear, the unit will stop cycling.

Low Battery Warning

If the battery power (base station or remote sensor) is low, there will be a low battery icon showing on the base station display.If the low battery icon for the base station appears, please replace the batteries with new batteries.If the low battery icon for the remote sensor appears, please charge the remote sensor as soon as you can.

Installing Batteries

  1. Base station: open the battery compartment of the base station and insert two “AAA” batteries with the correct polarity.
  2. Remote sensor: A built-in rechargeable lithium battery is installed in the remote sensor. Although there could be some power in the rechargeable battery before the unit leaves the manufacturing facility, it is always good to fully recharge the remote sensor before using by following the steps below:

Note, the package does not INCLUDE a wall adapter. Simply use any cellphone wall charger with a USB socket to charge the battery.

a. Connect the charger to the charging socket located on the back of the remote sensor;b. Plug the charger into a standard AC outlet;c. The red light on the remote sensor will light up;d. Charge it for at least 4 hours until the light changes from red to green which indicates charging is complete.

Place the Base Station and Remote Sensor

  1. The indoor base station (receiver) should always be placed in a well-ventilated indoor area and located away from vents, heating or cooling elements, direct sunlight, windows, doors, or any other openings.
  2. The remote sensor (transmitter) can be placed on a flat surface indoors or outdoors. Make sure the sensor is within the wireless distance from the base station and with minimal obstructions. Although the remote sensor is designed to be rain-proof, it still must always be put in a dry place avoiding direct rainfall.
  3. The base station and remote sensor can both be wall mounted.

Maximum & Minimum Recorded Temperature & Humidity

  1. Press MAX/MIN/Clear button once to display the highest indoor and outdoor temperatures/humidity recorded. MAX is shown on the display.
  2. Press MAX/MIN/Clear button again to display the lowest indoor and outdoor temperatures/humidity recorded. MIN is shown on the display.
  3. To clear and reset the max/min records, press and hold MAX/MIN/Clear for 3 seconds.
  4. When the MAX or MIN records are shown on the LCD display, press the ALL-TIME/24 button once to select the data recording time interval between ALL TIME or 24 hours.

Note: Both ALL TIME and 24 hours represent the time since you last time manually cleared the history data or battery installation.

Hints and Tips

If the receiver can’t connect to the transmitter, try the following:

  • Repeat the synchronization process as described above.
  • Relocate the base station or the remote unit until the connection is established again.
  • Signals from other electronic devices may cause Place the base station and receiver away from these devices.
  • If the base station is attached to a refrigerator or a metal object by a magnet, the transmission range may be Remove the base station from the refrigerator or the metal object or place the base station and remote sensor as close as possible.

Warnings

  • Do not subject the unit to excessive force, shock, dust, temperature, or humidity.
  • Do not immerse the unit in water.
  • Do not remove any screws.
  • Do not dispose of this unit in a fire. IT MAY EXPLODE.
  • Keep unit away from children. The unit or parts of the unit might be a choking hazard.
  • Dispose of the unit legally and recycle when possible.

Specifications

  1. Maximum Transmit Power: 8mW.
  2. Transmission range up to 500 feet in an open area. (range may be shorter based on interference present).
  3. Indoor Temperature range: -4°F-158°F (-20°C-70°C).
  4. Outdoor Temperature range: -31°F-158°F(-35°C-70°C).
  5. Humidity range: 10% — 99%.
  6. Temperature tolerance: ±0.5°F (±0.3°C).
  7. Humidity tolerance: ±2%.
  8. Power: 2 X AAA 1.5V for the base unit and 18650 lithium battery 3.7V for remote sensor.

FCC STATEMENT OF COMPLIANCE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:

– Reorient or relocate the receiving antenna.– Increase the separation between the equipment and the receiver.– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

Declaration of Conformity

Hereby, the manufacturer declares that this product complies with the basic requirements and applicable regulations of the Radio Equipment Directive 2014/53/EU, the EMC Directive 2014/30/EU. The complete declaration of conformity can be found at: https://itronicsmall.com/eu-declaration-of-conformity/

Disposal

Meaning of the “Dustbin” Symbol

  • Protect our environment: do not dispose of electrical equipment in the domestic
  • Please return any electrical equipment that you will no longer use to the collec­tion points provided for their disposal.
  • This helps avoid the potential effects of incorrect disposal on the environment and human health.
  • This will contribute to the recycling and other forms of utilization of electrical and electronic equipment.
  • Information concerning where the equipment can be disposed of can be obtained from your local authority.

CAUTION: Batteries/rechargeable batteries must not be disposed of with household waste!

  • The batteries must be removed from the appliance.
  • Take spent batteries to the appropriate collection point or to a dealer.
  • Your town or local authority can provide information about public collection points.

This symbol can be found on batteries/rechargeable batteries which contain hazardous.

  • Pb = contains lead
  • Cd = contains cadmium
  • Hg = contains mercury
  • Li = contains lithium

Limited one-year warranty

ThermoPro warrants this product to be free of defects in parts, materials, and workmanship for a period of one year, from the date of purchase.Should any repairs or servicing under this warranty be required, contact Customer Service by phone or email for instructions on how to pack and ship the product to ThermoPro.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Purchasing additional remote sensors

Additional sensors may be ordered directly from Amazon or ThermoPro by contacting our customer service listed below.

Customer service

Telephone: 1-877-515-7797 (USA & Canada only) 44-808-164-1683(UK)Email: [email protected]Hours: Weekdays 8:00 AM – 8:00 PM EST(USA & Canada only) 1:00 PM -12:00 PM CET(UK)

[xyz-ips snippet=”download-snippet”]


Posted

in

by