7 Day Digital2 Channel Heating &Hot Water ProgrammerCat. No. TRT036Cat. No. TRT036Operating & Installation Instructions
What is a programmer?…an explanation for householders
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times.Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time.You may be able to temporarily adjust the heating program, for example, ‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature.
Introduction
TRT products are a cost-effective comprehensive range of thermostats and controllers designed for internal use only.The TRT036 is a two-channel programmer dedicated to central heating and hot water, with automatic summer/winter time changeover (which can be canceled), 5 day plus 2 or 7 (individual) day programming, pumped or gravity fed system, holiday mode, boost function, advance to next program and permanent on/off override. There are three timed control periods per day.The unit is fitted with a factory-installed battery which gives up to 24 hours back up of time, date, and programs in the event of a mains failure.It is designed to be surface mounted on its supplied wall plate.The electrical supply must be isolated before removing the thermostat from the wall plate.
TRT036 7 Day Digital Programmer
Fig. 1
Rear View of TRT036
ContentsTRT036 programmerTRT036 wall plateTRT036 instruction leaflet2 x wall plugs2 x screws
Siting
The TRT036 should be located at a position that eases wiring runs and gives good access for programming. It should be mounted approximately 1.5m above floor level.
Installation
This product should be installed by a qualified installer to current installation standards.If in any doubt contact the Timeguard Helpline 020 8450 0515.Always isolate the mains supply before removing the unit from its wall plate.The TRT036 is designed to be surface mounted on the supplied wall plate.Isolate 230VAC mains supply.The incoming and outgoing cable should be 1.5mm sq.
Remove wall plate from the unit, by undoing retaining screws, and pivoting the bottom of the unit outwards. The unit can then be lifted off. Pass incoming wires through opening in a wall plate, and fix wall plate securely to the wall, using screws provided. The screws which secure the product to the wall plate should point downwards.Allow sufficient excess cable to wire up the unit, but not too much to make it difficult to close the unit to the wall plate.Connect the conductors to the relevant terminal, according to the wiring diagram on the wall plate (or below). Ensure that the curved brass washer grips the conductor.
Wiring Diagram
This unit is double insulated and hence does not need a connection to the earth. If earth continuity is required, please use the earth terminal on wall plate. To reinstall the unit on the wall plate hook the top of the unit over the retaining tabs, and push firmly back.There will be some resistance from the terminals.Once in place, secure with the retaining screws.Restore mains to the unit after checking all system wiring is complete.
Operation
Decide whether weekday/weekend (5-2) or individual (7) day programming is required, and move the jumper on the rear of the product (see Fig. 2). Also move the system jumper to either G (gravity) or P (pumped) as appropriate for the system.It is important to make these decisions first, as after any change of jumper position, reset needs to be pressed, which will return the unit to the default time and program.ResetWhen programming a new unit or one that has been disconnected from the mains for more than 24 hours, open the program access flap and press the reset button (see Fig. 1a) using a pen or similar implement which will clear the memory.
All of the screen segments will show briefly, and then the default program will be displayed.Setting time and date To program the current time and date, simultaneously press and hold both the select and set
Once the time and date have been set, press set to exit back to the operating mode. If at any time a button is not pressed for 15 seconds, the unit will return to operating mode. Individual (7 day) programming on/off times The default on/off times for heating and hot water are as follows:
6:00 AM on8:00 AM off10:00 PM on12:00 PM off6:00 PM on10:00 PM off
These apply to every day independent of whether weekday/weekend (5-2) or individual (7) day option is chosen. Note: to omit days and programs please refer to “Omitting days and programs” To change from default values, proceed as follows:Press set and MON will flash (with the program (P) 1 on time for heating Press set and MON will flash (with program
Omitting days and programsDays can be omitted by entering the same time in each of the 3 on/off programs for that day.In 5-2 day mode the weekend can be omitted by using the same technique for the 2 day (Sat & Sun) programs.A program (usually P2) can also be omitted for a given day by making the P2 on and off times the same.This can also be applied to P1 and P3 if required.BoostIn operating mode, there is a boost facility for between 1 and 9 hours in one-hour steps. Press the boost button the required number of times for the number of hours of boost required.The programmer returns to operating mode 15 seconds after the last button push. To cancel boost, press the boost button until 0 hrs is shown.Press and hold the light button and the programmer will enter holiday mode. Use the buttons
To clean use a clean dry cloth only. Do not use any liquid cleaners.Gravity SystemAlthough the hot water may be programmed to come on at different times to the heating, by the nature of the system, it will also come on during all the on times programmed for heating. This will also be true when in boost or advanced modes.
SpecificationsCurrent rating: 3 (1) AVoltage: 230V, 50HzSwitch type: single pole, double-throw (SPDT) for both heating and hot waterOperating temperature range: 0ºC to 50ºCComplies with: BS EN 60730Conforms to directives: Conforms to the latest directivesMicro disconnection: Type 1.B control action
For assistance with the product please contact:-HELPLINE020 8450 0515 or email [email protected]
3 Year GuaranteeIn the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible replacements (were agreed on byTimeguard Ltd) the customer is responsible for all shipping/ postage charges for sending replacements outside the UK. All shipping costs are to be paid in advance before a replacement is sent.
For a product brochure please contact:Timeguard Ltd. Victory Park, 400 Edgware Road,London NW2 6ND Tel: 020 8452 1112or email [email protected]