TRIPP-LITE PDU12IEC PDU Rack Mount Power Strip Owner’s Manual

TRIPP-LITE PDU12IEC PDU Rack Mount Power Strip Owner’s Manual

Important Safety Instructions

This manual contains information concerning the proper installation and use of Tripp Lite’s Rack mount Power Strips.

SAVE THESE INSTRUCTIONS. 

Do not connect your power strip to an ungrounded outlet. Do not use it with extension cords or adapters that eliminate its connection to ground. Your power strip is designed for indoor use only. Install it away from heat emitting devices such as radiators and heat registers. Do not install where excessive moisture or other conductive contaminants are present. Never install electrical wiring during a lightning storm.

The power requirement of each device connected to an outlet of your power strip must not exceed the Output Power Rating of your power strip (see Specifications). The total power requirements of all devices connected to your power strip must not exceed the Maximum Load Rating of your power strip (see Specifications).

CAUTION Only those who are properly trained or qualified to use this device should do so. Anyone who is not trained or qualified should not use this device unless it is under the supervision of someone who is properly trained or qualified to do so.

Children must be supervised to ensure that they do not use the device as a toy.

Never use the device if the cord and plug are damaged; if it is not working properly, or if it has been dropped or damaged, take it to an authorized service center for inspection and repair.

If the power cord is damaged, it must be replaced by the manufacturer, its authorized service agent, or by qualified personnel in order to avoid a danger.

Installation

1U Rackmount Installation

To Mount Unit in Rack: Put four user-supplied rackmount screws (A) through the unit’s mounting ears (B) and into the rack rails as shown. The user must determine the fitness of the rackmount screws to hold the unit in the rack before installation.

0U Rackmount Installation

  1. Reorient Mounting Ears: Unscrew the screws (A) holding the unit’s mounting ears (B) to the sides of the unit. Use the screws from Step 1 (A) to reattach the mounting ears (B) to the unit as shown. Use only the manufacturer-supplied screws or their equivalent (#6-32, ¼” flat head) to reattach the mounting ears.
  2. Mount Unit on Outside of Rack Rails: Put four user-supplied screws (C) or similar mounting hardware through the unit’s mounting ears (B) and into the side of the rack as shown. The user must determine the fitness of the user-supplied mounting hardware to support the unit before mounting.

Wallmount/Under Counter Installation

Reorient the unit’s mounting ears as per the 0U Rackmount Installation above, then put four usersupplied screws or similar mounting hardware through the unit’s mounting ears and into the mounting surface. The user must determine the fitness of the user-supplied mounting hardware to support the unit before mounting

Connecting the PDU

Note: The PDU12IEC has no power cord. Instead, it has an IEC C20 inlet receptacle. To connect the PDU12IEC to utilitypower, the user must supply a detachable power cord with an IEC C19 plug on one end and a plug appropriate for the localutility outlets on the other.

Attach a user-supplied power cord to the PDU by inserting the IEC C19 connector (A) of the power cord into the cable clamp and IEC C20 power inlet (B) located near the end of the PDU. Install the cable clamp to the PDU chassis (C) using the provided screws. Then install and tighten the third screw (D) as needed to secure the power cord connection. Connect the other end of the input power cord to a compatible source of AC power, such as a UPS system, PDU or utility outlet.

Features

Worldwide Compatibility for Maximum Application FlexibilityThe PDU12IEC accepts 16A input power over a 100-240V range, making it compatible worldwide.The IEC C20 inlet accepts any country-specific power cord with an IEC C19 connector, and the 12 IEC C13 (four front-facing, eight rear-facing) and two rear IEC C19 outlets offer additional flexibility when connecting multiple items of equipment. All outlets can be adapted for specific applications with an appropriate plug adapter.

Circuit Breaker(s)If the current draw of the equipment connected to your power strip exceeds your model’s Maximum Load Rating (see Specifications) for longer than a few seconds, a circuit breaker will trip to prevent any possible damage. When a circuit breaker trips, its plunger will pop up. Remove excess equipment and allow the breaker to cool one minute before depressing its plunger to reset the breaker.

Grounding LugUse this screw (located by the power strip’s receptacles) to connect your power strip to ground.

Specifications

  • Nominal Voltage/Frequency:100V to 240V/50 or 60Hz
  • Output Power Rating (amps):15 amps for 100V to 120V or 16 amps for 208 to 240V
  • AC Receptacles:4 x IEC C13 (front), 8 x IEC C13 / 2 x IEC C19 (rear)
  • AC Line Cord:N/A (IEC C20 inlet)
  • Maximum Load Rating (amps):16 amps
  • Circuit Breaker(s) (Resettable):2 x 16 amps
  • Dimensions (HxWxD):1¾ × 17¼ × 3¾ in. (44 x 445 x 108 mm)

Limited Warranty

Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for a period of 5 years (except internal UPS system batteries outside USA and Canada, 1 year) from the date of initial purchase. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609 USA. Seller will pay return shipping charges. Visit www.tripplite.com/support before sending any equipment back for repair

THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTEND PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction).

WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application.

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

 

References

[xyz-ips snippet=”download-snippet”]