TSI TA410 Ventilation Testing Air Velocity Meter User Manual

AIR VELOCITY METERALNOR® MODEL AVM410AIRFLOWTM INSTRUMENTSMODEL TA410OPERATION AND SERVICE MANUAL

P/N 1980575, REV GNOVEMBER 2020

START SEEING THE BENEFITS OF REGISTERING TODAYThank you for your TS! instrument purchase. Occasionally, TS! releases information on software updates, product enhancements and new products. By registering your instrument, TSI will be able to send this important information to you.http://register.tsi.comAs part of the registration process, you will be asked for your comments on 151 products and services. 151’s customer feedback program gives customers like you a way to tell us how we are doing.

UNDERSTANDING, ACCELERATEDTSI Incorporated Visit our website www.tsi.com for more information.USA Tel: +1 800 874 2811India Tel: +9180 67877200

CopyrightTSI Incorporated / 2007-2020 / All rights reserved.AddressTSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USAFax No. (651) 490-3824Limitation Of Warranty And Liability (effective February 2015)(For country-specific terms and conditions outside of the USA, please visit www.tsi.com.)

Seller warrants the goods, excluding software, sold hereunder, under normal use and service as described in the operator’s manual, to be free from defects in workmanship and material for 24 months, or if less, the length of time specified in the operator’s manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions and exceptions:a. Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment;b. Pumps are warranted for hours of operation as set forth in product or operator’s manuals;c. Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment;d. Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer’s warranty applies;e. This warranty does not cover calibration requirements, and seller warrants only that the instrument or product is properly calibrated at the time of its manufacture. Instruments returned for calibration are not covered by this warranty;f. This warranty is VOID if the instrument is opened by anyone other than a factory authorized service center with the one exception where requirements set forth in the anual allow an operator to replace consumables or perform recommended cleaning;g. This warranty is VOID if the product has been misused, neglected, subjected to accidental or intentional damage, or is not properly installed, maintained, or cleaned according to the requirements of the manual. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller.The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO THE SELLER’S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS. BUYER’S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER’S OPTION REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS.TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER’S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, THE SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE  OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENT SHALL THE SELLER BE LIABLE FOR LOST PROFITS, BUSINESS INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller’s factory shall be at Buyer’s risk of loss, and will be returned, if at all, at Seller’s risk of loss. Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an officer of Seller.Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call the Customer Service department at +44 (0) 149 4 459200 (UK), (800) 680-1220 (USA), or (1) 651-490-2860 (International).Trademarks TSI, the TSI logo, Alnor, and Airflow Instruments are registered trademarks and trademarks of TSI Incorporated in the United States and may be protected under other country’s trademark registrations.

Chapter 1 Unpacking and Parts Identification

Carefully unpack the instrument and accessories from the shipping container. Check the individual parts against the list of components below. If anything is missing or damaged, notify TSI® Incorporated immediately.1. Carrying case2. Instrument

Chapter -2 Setting-up

Supplying Power to the Alnor® AVM410/AirflowTM Instruments TA410

The Alnor® AVM410/AirflowTM Instruments TA410 is powered with four size AA batteries.

Installing the Batteries

Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Alnor® AVM410/ AirflowTM Instruments TA410 is designed to operate with either alkaline or NiMH rechargeable batteries, although it will not recharge NiMH batteries. Battery life will be shorter if NiMH batteries are used. Carbon-zinc batteries are not recommended because of the danger of battery acid leakage.

Using the Telescoping

Probe The telescoping probe contains the velocity and temperature sensors. When using the probe, make sure the sensor window is fully exposed and the orientation dimple is facing upstream.NOTE For temperature measurements, make sure that at least 3 inches (7.5 cm) of the probe is in the flow to allow the temperature sensor to be in the air stream.

Extending the Probe

To extend the probe, hold the handle in one hand while pulling on the probe tip with the other hand. DO NOT hold the cable while extending the probe as this prevents the probe from extending.

Retracting the Probe

To retract the probe, hold the handle in one hand while pulling gently on the probe cable with the other hand.

Chapter 3 Operation

Keypad Functions
ON/OFF Key Press to turn the Alnor® AVM410/AirflowTm Instruments TA410 on and off. During the power-up sequence, the display will show the following: Model Number, Serial Number, Software Revision, and Last Date Calibrated.
ft/min / m/s Key Pressing this key changes the display to read air velocity.
°C / °F Key Pressing this key changes the display to read the temperature.
Changing Units To change units, first put the desired measurement (air velocity or temperature) on the display. Then press and hold the left, unlabelled key for five seconds. Finally, use the and ENTER keys to select the units.

Chapter -4Maintenance

The Alnor® AVM410/AirflowTM Instruments TA410 requires very little maintenance to keep it performing well.

Recalibration

To maintain a high degree of accuracy in your measurements, we recommend that you return your Alnor® AVM410/AirflowTM Instruments TA410 to TSI® Incorporated for annual recalibration. Please contact one of TSI’s offices or your local distributor to make service arrangements and to receive a “Service Request” number. To fill out an online “Service Request” form, visit TSI’s website at tsi.com/service.

U.S. & International UK
 TSI IncorporatedAlnor® Products 500Cardigan RoadShoreview MN 55126-3996 Tel: (800) 680-1220(651) 490-2860 Fax: (651) 490-3824 TSI Instruments Ltd.Stirling RoadCressex Business ParkHigh Wycombe BuckinghamshireHP12 3ST the United KingdomTel: +44 (0) 149 4 459200
Cases

If the instrument case or storage case needs cleaning, wipe it off with a soft cloth and isopropyl alcohol or a mild detergent. NEVER immerse the Alnor® AVM410/AirflowTM Instruments TA410. If the enclosure of the Alnor® AVM410/AirflowTM Instruments TA410 becomes broken, it must be replaced immediately to prevent access to hazardous voltage.

Storage

Remove the batteries when storing the unit for more than one month to prevent damage due to battery leakage.

Chapter 5 -Troubleshooting

Table 5-1 list the symptoms, possible causes, and recommended solutions for common problems encountered with the Alnor® AVM410/AirflowTM Instruments TA410. If your symptom is not listed, or if none of the solutions solves your problem, please contact TSI® Incorporated.Table 5-1: Troubleshooting the Alnor® AVM410/Airflow® Instruments TA410

Symptom Possible Causes Corrective Action
No Display Unit is not turned on Switch unit on.
Low or dead batteries Replace batteries or plug in an AC adapter.
Dirty battery contacts Clean the battery contacts.
Velocity reading fluctuates unstable Fluctuating flow

 

Reposition probe in less-turbulent flow
Instrument Error message appears Fault in instrument Factory service required on the instrument.

WARNING!Remove the probe from excessive temperature immediately: excessive heat can damage the sensor. Operating temperature limits can be found in Appendix A, Specifications.

Specifications

Specifications are subject to change without notice.Velocity: Range:………………………… 0 to 4000 ft/min (0 to 20 m/s)Accuracy1&2: ………………… ±5% of reading or ±5 ft/min (±0.025 m/s),whichever is greater Resolution: ………………….. 1 ft/min (0.01 m/s)Temperature: Range:………………………… 0 to 200°F (-18 to 93°C)Accuracy3: …………………… ±0.5°F (±0.3°C)Resolution: ………………….. 0.1°F (0.1°C)Instrument Temperature Range: Operating (Electronics): … 40 to 113°F (5 to 45°C)Operating (Probe): ……….. 0 to 200°F (-18 to 93°C)Storage:………………………. -4 to 140°F (-20 to 60°C)External Meter Dimensions: 3.3 in. 7.0 in. 1.8 in. (8.4 cm 17.8 cm 4.4 cm) MeterWeight: Weight with batteries:……. 0.6 lbs (0.27 kg)Power Requirements: Four AA-size batteries (included)

  1. Temperature-compensated over an air temperature range of 40 to 150°F (5 to 65°C).
  2. The accuracy statement of ±5.0% of reading or ±5 ft/min (±0.025 m/s), whichever is greater, begins at 30 ft/min through 4000 ft/min (0.15 m/s through 20 m/s).
  3. Accuracy with instrument case at 77°F (25°C), add the uncertainty of 0.05°F/°F (0.03°C/°C) for change in instrument temperature.

Notes………

TSI IncorporatedVisit our website www.tsi.com for more information.USA Tel: +1 800 680 1220India Tel: +91 80 67877200

TSI Instruments Ltd.Visit our website at www.tsi.com for more information.

UK Tel: +44 149 4 459200France Tel: +33 1 41 19 21 99P/N 1980575 Rev. G©2020 TSI IncorporatedPrinted in the U.S.A.