Turbosound iQ Series Powered Loudspeaker/Subwoofer User Guide

Quick Start Guide

iQ Series2500 Watt 2 Way 8″/10″/12″/15″ Powered Loudspeaker 3000 Watt 15″/18″ Powered SubwooferKLARK TEKNIK DSP Technology, Speaker Modelling and ULTRANET Networking

Important Safety Instructions

CAUTIONRISKOFELECTRICSHOCK!DO NOT OPEN!ATTENTION

Terminals marked with this symbol carry an electrical current of sufficient magnitude to constitute a risk of electric shock. Use only high-quality professional speaker cables with ¼” TS or twist-locking plugs pre-installed. All other installation or modifications should be performed only by qualified personnel.

This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure – voltage that may be sufficient to constitute a  risk of shock.

This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.

CautionTo reduce the risk of electric shock, do not remove the top cover (or the rear section). No user-serviceable parts inside. Refer servicing to qualified personnel.

CautionTo reduce the risk of fire or electric shock, do not expose this appliance to rain and moisture. The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids, such as vases, shall be placed on the apparatus. CautionThese service instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform anyservicing other than that contained in the operation instructions. Repairs have to be performed by qualified service personnel.

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with a dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. Use only attachments/accessories specified by the manufacturer.
  12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
  13. Unplug this apparatus during lightning storms or when unused for long periods of time.
  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  15. The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
  16. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
  17. Correct disposal of this product: This symbol indicates that this product must not be disposed of with household waste,according to the WEEE Directive (2012/19/EU) and your national law. This product should be taken to a collection center licensed for the recycling of waste electrical and electronic equipment (EEE). The mishandling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the efficient use of natural resources. For more information about where you can take your waste equipment for recycling, please contact your local city office or your household waste collection service.
  18. Do not install in a confined space, such as a bookcase or similar unit.
  19. Do not place naked flame sources, such as light candles, on the apparatus.
  20. Please keep the environmental aspects of battery disposal in mind. Batteries must be disposed of at a battery collection point.
  21. Use this apparatus in tropical and/or moderate climates.

LEGAL DISCLAIMER

MUSIC Tribe accepts no liability for any loss which may be suffered by any person who relies either wholly on or in part upon any description, photograph, or statement contained herein. Technical specifications, appearances, and other information are subject to change without notice. All trademarks are the property of their respective owners. MIDAS, KLARK TEKNIK, LAB GRUPPEN, LAKE, TANNOY, TURBOSOUND, TC ELECTRONIC, TC HELICON, BEHRINGER, BUGERA, and COOLAUDIO are trademarks or registered trademarks of MUSIC Tribe Global Brands Ltd. © MUSIC Tribe Global Brands Ltd. 2018 All rights reserved.

LIMITED WARRANTY For the applicable warranty terms and conditions and additional information regarding MUSIC Tribe’s Limited Warranty, please see complete details online at music. be/warranty.

Thank you for choosing a TURBOSOUND loudspeaker product for your application. If you would like further information about this or any other TURBOSOUND product, please visit our website at turbosound.com.

Unpacking the Loudspeaker

After unpacking the unit please check carefully for damage. If damage is found, please notify your supplier at once. You, the consignee, must instigate any claim. Please retain all packaging in case of future re-shipment.

Controls

(1) LCD SCREEN displays the current DSP module and parameter settings.(2) SETUP button steps through parameters within DSP processing modules.(3) PROCESS button steps through the DSP processing modules.(4) SIGNAL LED lights up to indicate the channel is receiving a signal.(5) GAIN controls adjust the analog input level. To increase signal gain, rotate the controls clockwise; to reduce the gain, rotate the knobs counter-clockwise. (Fullrange models have separate GAIN knobs for channels A and B, while iQ15B and iQ18B subwoofers have a single dedicated A/B knob for both channels.)(6) OUTPUT A/OUTPUT B XLR connectors provide un-processed copies of the INPUT A or INPUT B signals.(7) LINE/MIC switch adjusts the input sensitivity for INPUT A and INPUT B.(8) INPUT A/INPUT B combo jacks accept input signals using XLR, balanced ¼” TRS, or unbalanced ¼” TS connectors.(9) POWER switch turns the unit on and off.(10) AC INPUT accepts power connections from power cables fitted with Neutrik powerCON twist-locking connectors.(11) ENCODER KNOB toggles between Graphic and Edit modes (when pressed) and changes parameter values (when rotated).(12) EXIT button returns to the top-level DSP screen when pressed.(13) ENTER button saves changes and deactivates Edit mode when pressed.(14) MIX OUTPUT XLR jack (unavailable on iQ15B and iQ18B subwoofers) sends out a post-GAIN signal composed of the summed INPUT A and INPUT B signals.(15) USB connection enables firmware updates and remote control over parameters via computer. Please visit turbosound.com to download DSP control software for your computer.(16) ULTRANET THRU sends out unprocessed digital audio from the ULTRANET IN connector to additional ULTRANET-equipped devices.(17) ULTRANET IN RJ45 plug comes with 2 linked green status LEDs. Whenever a CAT5 cable has been connected, and a valid ULTRANET signal is detected, both LEDs will light up simultaneously to indicate that the ULTRANET signal is ready to use.(18) VENTILATION FAN speed adjusts automatically to ensure trouble-free operation.(19) AC LINK OUTPUT connects power to other devices using power cables with Neutrik powerCON twist-locking connectors.

Networking capability

All iQ powered loudspeakers offer remote control via USB. The USB connection allows the user to configure and monitor all DSP parameters using dedicated iQ software for PC.The DSP firmware can also be updated via the USB connection. Visit turbosound.com for the latest firmware version.iQ speakers also offer proprietary ULTRANET networking capabilities through the ULTRANET IN and THRU connections using CAT5 cables with RJ45 connectors.ULTRANET allows the user to transmit unidirectionally up to 16 independent channels of 24-bit audio throughout the iQ system, as well as other ULTRANET-equipped devices such as digital mixers and personal monitor systems. Up to 7 devices can be connected in series on a single ULTRANET cable. ULTRANET can also be used for remote control of the iQ selection of modeled speakers.

ULTRANET connection with MIDAS M32 digital mixer and MIDAS DL16 digital snake

Networked mains power

iQ loudspeakers also facilitate the networked transmission of mains power using power cables with Neutrik powerCON locking power connectors. To set up networked mains power between iQ loudspeakers, first, run a power cable terminating in a powerCON connector to the AC INPUT connector on the rear panel. To power additional speakers downline, run power cables equipped with powerCON connectors at both ends from the first speaker’s AC LINK OUTPUT to the AC INPUT of the next iQ loudspeaker in series. The maximum number of linked systems depends on the AC supply voltage as well as the maximum current draw of the individual systems in the power chain. When linking a power chain, make sure that the integrated connectors as well as the supplied AC mains cable are never overloaded. If you are uncertain how to calculate the total current draw, please contact your dealer.

iQ DSP Menu Structure

Full range Subwoofer FunctionChoose from different sound Models, either the

Model “XYZ” Model “XYZ” TURBOSOUND signature voicing or a DSP model of an industry-standard product.
None  

None

Sets the frequency response to the default setting.
Live Live Sets the frequency response to a typical live sound setting.
Speech Speech Sets the frequency response for optimal speech intelligibility.
Playback Playback Sets the frequency response ideal for music playback.
User User Lets you define your own frequency response setting by entering the corresponding sub-menu.
Low/ High Shelving Low/ High Shelving Let’s define a low and high shelving filter.
Parametric 1 & 2 Parametric 1 & 2 Lets you define a parametric bell-type EQ (Frequency, Qual and Gain).
None None Unit is set for default full range/ subwoofer reproduction.
iQ8 Preset with ideal settings for use in combination with iQ8 full range speaker.
iQ10 Preset with ideal settings for use in combination with iQ10 full range speaker.
iQ12 Preset with ideal settings for use in combination with iQ12 fullrange speaker.
iQ15 Preset with ideal settings for use in combination with iQ15 fullrange speaker.
iQ15B Preset with high pass alignment for iQ15B subwoofer.
iQ18B Preset with high pass alignment for iQ18B subwoofer.
User User User crossover sub-menu for combination with other full range or subwoofer speaker systems.
Freq Freq Select the desired crossover frequency: For Fullrange Systems: 75 Hz to 400 Hz For Subwoofer Systems: 50 Hz to 150 Hz
Phase Phase Adjust the absolute phase (0° or 180°)
Fullrange Subwoofer Function
Auto Auto Automatically sets as many filters as required. Whenever a new feedback frequency is discovered, the first filter will be released to attenuate the new frequency, and so forth.
Single Single Activates the FBQ (feedback detection) functionality, up to 8 feedback filters.
Learn Learn Automatic procedure which searches for feedback frequencies and locks settings after all 8 filters have been set.

WARNING!

Please use ear protection during this procedure. The feedback signal may approach the system’s maximum level, which may cause hearing damage!

Reset Reset Resets all filters.
SETUP (page 1) INPUT Input Input Let’s you choose the audio input source. Chose between Local (Analogue Input) or ULTRANET (e.g., P16 monitoring system or

M32 audio via ULTRANET).

  Trim Trim Adjusts the input gain of the ULTRANET digital inputs in a range

FM +10 dB to – 30 dB

Remote Remote Enables ULTRANET remote control functionality in order to protect against misuse.
VU VU Displays the respective input level of all 16 channels receiving via ULTRANET; only visible when ULTRANET input is selected.
Stand Floor For positioning the speaker on a pole mount stand (full range) or on the floor (subwoofer).
 

Wall

 

Wall

For positioning the speaker on or next to a wall (fixed install); alternatively as a monitor speaker (wedge).
Ceiling For positioning the speaker on a wall next to the ceiling (fixed install).
 

Corner

 

Corner

For positioning the speaker in a corner next to the ceiling (fixed install); For positioning the speaker in a corner (subwoofer).
 

Delay

 

Delay

Adjusts the amount of delay (max 300msec = 103.08m or 338.19 feet).
Unit Unit Selects between msec, meter, and feet.
Limit Limit Adjust the limiter threshold for the input signal (from OFF up to -30 dB). This threshold adjustment allows you to set a max output power that is below the IQ system’s rated max output.
Full range Subwoofer Function
Version Version Displays the installed firmware version.
1. – 20. 1. – 20. To load a specific preset, turn the encoder to select the desired pet’s number, and then either the ENTER button or the encoder. When asked to confirm press the encoder again or EXIT to abort.
1. – 20. 1. – 20. To save a preset choose the respective preset slot and press ENTER or the encoder.
Save Preset Save Preset Name the preset by choosing the characters with the encoder and pressing to confirm each

character. When finished, press the ENTER button to save the preset.

Contrast Contrast Adjust LCD panel contrast.

The default contrast value is 15.

Screen Screen ON: LCD screen saver (default) turns on automatically after approx. 2 minutes.

OFF: LCD turns off automatically after approx. 5

minutes.

Logo Logo OFF: Deactivates front panel logo illumination.

ON: Activates front panel logo illumination.

LIMIT: Logo will light up when the limiter is active.

Lock Lock Lock the device and creat a password by choosing the password characters with the encoder

and pressing to confirm each character. When finished press the ENTER button. Unlock the device by entering the password or connecting the unit via USB to a PC running iQ software. The software does not require a password.

Warning Warning In case of overheating, an alert appears on the LCD screen, and the amplifier will shut down until the unit cools.

LCD Graphic Indicators

To help the user immediately recognize that a parameter has been selected and changed from the initial default setting, the parameter’s related text on the top-level screen will invert and change to black text on a white background. As an example, the following screenshots show how the text for the MODEL function changes when the iQ8 default sound has been changed to the modeled PS8 sound:

This indicator function occurs only on the main DSP menu level and works for all DSP-related functions, except for the LOAD, SAVE, and SETUP sub-sections on the second page of the top-level SETUP menu.

Mounting and fixing

iQ series powered loudspeakers are designed with multiple internal rigging points to suit many possible mounting methods in permanent installations. All cabinets can be simply suspended using optional M10 eyebolts coupled to the internal rigging points provided on the top, bottom, sides, and back. The simplest method is to use the two rigging points on the top and a single pull-back rigging point in the center of the rear panel. Remove the appropriate plastic caps and insert eyebolts, which must have a thread length of at least 30 mm. Use the rear rigging point to angle the cabinet for optimum room coverage.

Wall and Ceiling BracketsTURBOSOUND iQ8-WB, iQ10-WB, iQ12-WB, and iQ15-WB wall and ceiling brackets are optionally available for the iQ series.The graphic below shows the assembly of the optional mounting brackets (iQ8-WB, iQ10-WB, iQ12-WB, and iQ15-WB).

Step 1: Secure Yoke Spacers

ITEM

DESCRIPTION

QUANTITY

1 Yoke spacer 2
2 M5 x 25 mm screw with nylon thread locking 4

Step 2: Assemble Steel Yoke Bracket: IQ12 and iQ15

ITEM

DESCRIPTION

QUANTITY

1 Steel yoke bracket 1 1
2 Steel yoke bracket 2 1
3 Steel yoke bracket 3 1
4 M6 plain washer 6
5 M6 x 16 mm screw 6
6 M6 nylon locking nut 6

Step 2: Assemble Steel Yoke Bracket: iQ8 and iQ10

ITEM DESCRIPTION

QUANTITY

1 Steel yoke bracket 1 1
2 Steel yoke bracket 2 1
3 M5 x 15 mm screw 2(IQ8) 4(iQ10)
4 M5 plain washer 2(IQ8) 4(iQ10)
5 M5 nylon locking nut 2(IQ8) 4(iQ10)

Step 3: Place Speaker Into Yoke Bracket

ITEM DESCRIPTION

QUANTITY

1 Steel yoke bracket assembly 1
2 M8 x 25 mm screw 2
3 M8 plain washer 2
4 M8 spring lock washer 2

NOTE: For iQ8 and iQ10, the finished bracket requires only 2 pieces, while the iQ12 and iQ15 bracket requires 3 pieces.

Pole Mounting

Fullrange iQ loudspeaker models (iQ8, iQ10, iQ12, and iQ15) may also be pole-mounted, either independently or in conjunction with iQ subwoofer models (iQ15B, iQ18B). The IQ pole mount sockets allow full range models to be mounted straight or angled 7.5° downwards for optimum coverage. iQ10, iQ12, and iQ15 models may also be placed on one side and deployed as wedge monitors. These models have been designed with sides angled at 48° to help with upward sound dispersion.

Transport

The subwoofers are supplied with castors for ease of transportation when used as a portable sound system. To assemble the castors to the back of the cabinets, remove the 16 bolts from the rear of the speaker, align the castors with the mount holes and replace the bolts.IMPORTANT NOTE: The mounting of a permanently installed sound system may be dangerous unless undertaken by qualified personnel with the required experience and certification to perform the necessary tasks. Walls, floors, or ceilings must be capable of safely and securely supporting the actual load. The mounting accessory used must be safely and securely fixed both to the loudspeaker and to the wall, floor, or ceiling.

When mounting rigging components on walls, floors, or ceilings, ensure that all fixings and fasteners used are of an appropriate size and load rating. Wall and ceiling claddings, and the construction and composition of walls and ceilings, all need to be taken into account when determining whether a particular fixing arrangement can be safely employed for a particular load. Cavity plugs or other specialist fixings, if required, must be of an appropriate type, and must be fitted and used in accordance with the maker’s instructions.

The operation of your speaker cabinet as part of a flown system, if installed incorrectly and improperly, can potentially expose persons to serious health risks and even death. In addition, please ensure that electrical, mechanical, and acoustic considerations are discussed with qualified and certified (by local state or national authorities) personnel prior to any installation or flying. Make sure that speaker cabinets are set up and flown by qualified and certified personnel only, using dedicated equipment and original parts and components delivered with the unit. If any parts or components are missing please contact your Dealer before attempting to set up the system.

Be sure to observe the local, state, and other safety regulations applicable in your country. MUSIC Group, including the MUSIC Group companies listed on the enclosed “Service Information Sheet”, assumes no liability for any damage or personal injury resulting from improper use, installation, or operation of the product. Regular checks must be conducted by qualified personnel to ensure that the system remains in a secure and stable condition. Make sure that, where the speaker is flown, the area underneath the speaker is free of human traffic c. Do not fly the speaker in areas that can be entered or used by members of the public.

Speakers create a magnetic field, even if not in operation. Therefore, please keep all materials that can be affected by such fields (discs, computers, monitors, etc) at a safe distance. A safe distance is usually between 1 and 2 meters.

Technical Specifications

System

iQ8 iQ10

iQ12

Frequency response 60 Hz – 18 kHz ±3 dB55 Hz – 20 kHz -10 dB 55 Hz – 18 kHz ±3 dB50 Hz – 20 kHz -10 dB 52 Hz – 18 kHz ±3 dB45 Hz – 20 kHz -10 dB
Nominal dispersion 90° H x 90° V @ -6 dB points 90° H x 60° V @ -6 dB points 80° H x 60° V @ -6 dB points
Maximum SPL 128 dB peak 129 dB peak 130 dB peak
Crossover type Active Active Active
Transducers 1 x 8″ (208 mm) LF driver1 x 1″ (25.4 mm)HF compression driver 1 x 10″ (256 mm) LF driver1 x 1″ (25.4 mm)HF compression driver 1 x 12″ (308.5 mm) LF driver1 x 1″ (25.4 mm)HF compression driver
Limiter Independent HF, LF, peak, and RMS Independent HF, LF, peak, and RMS Independent HF, LF, peak, and RMS

Amplifier

iQ8 iQ 10 

iQ 12

Maximum output power* 2,500 W 2,500 W 2,500 W
Type Class-D Class-D Class-D
Protection Short circuit, open circuit, thermal Short circuit, open circuit, thermal Short circuit, open circuit,thermal

Connectors

IQ 8 IQ 10

IQ 12

Input A / B SensitivityInput impedance Maximum input level 2 x combo jack/XLR Line +4 dBu, mic -22 dBu, switchable 20 kΩ unbalanced, 40 kΩ balanced +21 dBu 2 x combo jack/XLR Line +4 dBu, mic -22 dBu, switchable 20 kΩ unbalanced, 40 kΩ balanced +21 dBu 2 x combo jack/XLR Line +4 dBu, mic -22 dBu, switchable 20 kΩ unbalanced, 40 kΩ balanced +21 dBu
Output A / B 2 x XLR Linked to input 2 x XLR Linked to input 2 x XLR Linked to input
Mix output Output impedance XLR, balanced 100 Ω unbalanced, 200 Ω balanced XLR, balanced 100 Ω unbalanced, 200 Ω balanced XLR, balanced 100 Ω unbalanced, 200 Ω balanced
Ultranet input/link 2 x RJ45 2 x RJ45 2 x RJ45
Mains Supply Neutrik powerCON input 20A and link 15A Neutrik powerCON input 20A and link 15A Neutrik powerCON input 20A and link 15A

Controls

IQ 8 IQ 10

IQ 12

DSP Rotary push-encoder Buttons for PROCESS, SETUP, EXIT, ENTER Rotary push-encoder Buttons for PROCESS, SETUP, EXIT, ENTER Rotary push-encoder Buttons for PROCESS, SETUP, EXIT, ENTER
Mixer section 2 x gain controls (channels A and B) 2 x Line/Mic switch 2 x gain controls (channels A and B) 2 x Line/Mic switch 2 x gain controls (channels A and B) 2 x Line/Mic switch

User DSP Functions

IQ 8 IQ 10

IQ 12

Factory EQ presets Positioning, Sound mode, Sound Modeling, FBQ Positioning, Sound mode, Sound Modeling, FBQ Positioning, Sound mode, Sound Modeling, FBQ
Display LCD 128 x 32, blue backlit LCD 128 x 32, blue backlit LCD 128 x 32, blue backlit
Delay 0 – 300 ms 0 – 300 ms 0 – 300 ms
Equalization High and low shelving EQ 2 x parametric EQ High and low shelving EQ 2 x parametric EQ High and low shelving EQ 2 x parametric EQ
Limiter Zero attack input limiter Zero attack input limiter Zero attack input limiter
Presets 20 total presets, 19 user-definable 20 total presets, 19 user-definable 20 total presets, 19 user-definable
Crossover High Pass L-R 24 dB/oct High Pass L-R 24 dB/oct High Pass L-R 24 dB/oct
Protection Lock-out function for all settings Lock-out function for all settings Lock-out function for all settings

Ultranet Digital Network

IQ 8 IQ 10

IQ 12

System Signal Latency 16 channels < 0.9 ms 16 channels < 0.9 ms 16 channels < 0.9 ms
Cabling Cables Cable length  

Shielded CAT5 max. 246 ft / 75 m recommended

Shielded CAT5 max. 246 ft / 75 m recommended Shielded CAT5 max. 246 ft / 75 m recommended

Power Supply

IQ 8 IQ 10

IQ 12

Power consumption 150 W @ 1⁄8 max power 150 W @ 1⁄8 max power 150 W @ 1⁄8 max power
Voltage (fuses)
USA / Canada 120 V~, 60 Hz (T 15 A H 250 V) 120 V~, 60 Hz (T 15 A H 250 V) 120 V~, 60 Hz (T 15 A H 250 V)
UK / Australia / Europe 220-240 V~, 50/60 Hz (T 10 A H 250 V) 220-240 V~, 50/60 Hz (T 10 A H 250 V) 220-240 V~, 50/60 Hz (T 10 A H 250 V)
Korea / China 220-240 V~, 50/60 Hz (T 10 AH 250 V) 220-240 V~, 50/60 Hz (T 10 AH 250 V) 220-240 V~, 50/60 Hz (T 10 A H 250 V)
Japan 100 V~, 50/60 Hz (T 15 AH 250 V) 100 V~, 50/60 Hz (T 15 AH 250 V) 100 V~, 50/60 Hz (T 15 A H 250 V)

Enclosure

IQ 8 IQ 10

IQ 12

Dimensions HWD 457 x 279 x 279 mm (18.0 x 11.0 x 11.0″) 526 x 324 x 316 mm (20.7 x 12.7 x 12.4″) 609 x 370 x 370 mm (24.0 x 14.5 x 14.5″)
Net weight 14.7 kg (32 lbs) 17.2 kg (38 lbs) 21.1 kg (46 lbs)
Construction Injection-molded polypropylene enclosure Injection-molded polypropylene enclosure Injection-molded polypropylene enclosure
Finish Black painted Black painted Black painted
Grille Powder-coated perforated steel Powder-coated perforated steel Powder-coated perforated steel
Flying hardware M10 x 3 points M10 x 3 points M10 x 3 points
Accessories IQ 8 IQ 10 IQ 12
IQ8-WB Steel wall bracket IQ10-WB Steel wallbracket IQ12-WB Steel wall bracket

System

IQ 8 IQ 10

IQ 12

Frequency response 50 Hz – 18 kHz ±3 dB

42 Hz – 20 kHz -10 dB

50 Hz – 130 Hz ±3 dB

40 Hz – 130 Hz -10 dB

50 Hz – 100 Hz ±3 dB

36 Hz – 100 Hz -10 dB

Nominal dispersion 75° H x 55° V @ -6 dB points Half Space Half Space
Maximum SPL 132 dB peak 130 dB peak 132 dB peak
Crossover type Active Active Active
Transducers 1 x 1″ (387 mm) LF driver1 x 1″ (25.4 mm)HF compression driver 1 x 15″ (385.7 mm) LF driver 1 x 18″ (460 mm) LF driver
Limiter Independent HF, LF, peak, and RMS Peak and RMS Peak and RMS

Amplifier

Maximum output power* 2,500 W 3,000 W 3,000 W
Type Class-D Class-D Class-D
Protection Short circuit, open circuit, thermal Short circuit, open circuit, thermal Short circuit, open circuit, thermal

Connectors

Input A / BSensitivity Input impedance Maximum input level 2 x combo jack/XLRLine +4 dBu, mic -22 dBu, switchable 20 kΩ unbalanced, 40 kΩ balanced +21 dBu 2 x combo jack/XLR Line +4 dBu 20 kΩ unbalanced, 40 kΩ balanced +21 dBu 2 x combo jack/XLR Line +4 dBu 20 kΩ unbalanced, 40 kΩ balanced +21 dBu
Output A / B 2 x XLR Linked to input 2 x XLR Linked to input 2 x XLR Linked to input
Mix output Output impedance XLR, balanced 100 Ω unbalanced, 200 Ω balanced N/AN/A N/AN/A
Ultranet input/link 2 x RJ45 2 x RJ45 2 x RJ45
Mains Supply Neutrik powerCON input 20A and link 15A Neutrik powerCON input 20A and link 15A Neutrik powerCON input 20A and link 15A
Controls
DSP Rotary push-encoder Buttons for PROCESS, SETUP, EXIT, ENTER Rotary push-encoder Buttons for PROCESS, SETUP, EXIT, ENTER Rotary push-encoder Buttons for PROCESS, SETUP, EXIT, ENTER
Mixer section 2 x gain controls (channels A and B) 2 x Line/Mic switch 1 x gain controls (channels A and B) 2 x Line 1 x gain controls (channels A and B) 2 x Line
User DSP Functions
Factory EQ presets Positioning, Sound mode, Sound Modeling, FBQ Positioning, Sound mode, Sound Modeling, FBQ Positioning, Sound mode, Sound Modeling, FBQ
Display LCD 128 x 32, blue backlit LCD 128 x 32, blue backlit LCD 128 x 32, blue backlit
Delay 0 – 300 ms 0 – 300 ms 0 – 300 ms
Equalization High and low shelving EQ 2 x parametric EQ High and low shelving EQ 2 x parametric EQ High and low shelving EQ 2 x parametric EQ
Limiter Zero attack input limiter Zero attack input limiter Zero attack input limiter
Presets 20 total presets, 19 user-definable 20 total presets, 19 user-definable 20 total presets, 19 user-definable
Crossover High Pass L-R 24 dB/oct Low Pass L-R 24 dB/oct Low Pass L-R 24 dB/oct
Protection Lock-out function for all settings Lock-out function for all settings Lock-out function for all settings

Ultranet Digital Network

iQ15 iQ15B

iQ18B

System SignalLatency 16 channels < 0.9 ms 16 channels < 0.9 ms 16 channels < 0.9 ms
Cabling CablesCable length Shielded CAT5 max. 246 ft / 75 m recommended Shielded CAT5 max. 246 ft / 75 m recommended Shielded CAT5 max. 246 ft / 75 m recommended
Power Supply
Power consumption 150 W @ 1⁄8 max power 200 W @ 1⁄8 max power 200 W @ 1⁄8 max power
Voltage (fuses)
USA / Canada 120 V~, 60 Hz (T 15 AH 250 V) 120 V~, 60 Hz (T 15 AH 250 V) 120 V~, 60 Hz (T 15 AH 250 V)
UK / Australia / Europe 220-240 V~, 50/60 Hz (T 10 AH 250 V) 220-240 V~, 50/60 Hz (T 10 AH 250 V) 220-240 V~, 50/60 Hz (T 10 AH 250 V)
Korea / China 220-240 V~, 50/60 Hz (T 10 AH 250 V) 220-240 V~, 50/60 Hz (T 10 AH 250 V) 220-240 V~, 50/60 Hz (T 10 AH 250 V)
Japan 100 V~, 50/60 Hz (T 15 AH 250 V) 100 V~, 50/60 Hz (T 15 AH 250 V) 100 V~, 50/60 Hz (T 15 AH 250 V)
Enclosure
Dimensions HWD 711 x 450 x 381 mm (27.9 x 17.7 x 15.0″) 602 x 445 x 495 mm (23.7 x 17.5 x 19.5″) 691 x 533 x 559 mm (27.2 x 21.0 x 22.0″)
Net weight 26.1 kg (57 lbs) 30.6 kg (67 lbs) 39.8 kg (87.5 lbs)
Construction Injection-molded polypropylene enclosure Birch plywood, screwed and glued Birch plywood, screwed and glued
Finish Black painted Black painted Black painted
Grille Powder-coated perforated steel Powder-coated perforated steel Powder-coated perforated steel
Flying hardware M10 x 3 points N/A N/A
Accessories
IQ15-WB Steel wall bracket

*independent of limiters and driver protection circuits

Other important information

Important information

  1. Register online. Please register your new MUSIC Tribe equipment right after you purchase it by visiting turbosound.com. Registering your purchase using our simple online form helps us to process your repair claims more quickly and efficiently. Also, read the terms and conditions of our warranty, if applicable.
  2. Malfunction. Should your MUSIC Tribe Authorized Reseller not be located in your vicinity, you may contact the MUSIC Tribe Authorized Fulfiller for your country listed under “Support” at turbosound.com. Should your country not be listed, please check if your problem can be dealt with by our “Online Support” which may also be found under “Support” at turbosound.com. Alternatively, please submit an online warranty claim at turbosound.com BEFORE returning the product.
  3. Power Connections. Before plugging the unit into a power socket, please make sure you are using the correct mains voltage for your particular model. Faulty fuses must be replaced with fuses of the same type and rating without exception.

FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION

TURBOSOUNDiQ18B/iQ15B/iQ15/iQ12/iQ10/iQ8

Responsible Party Name: MUSIC Tribe Brands UK Ltd.
Address: Klark Industrial Park, Walter Nash Road, Kidderminster, Worcestershire, DY11 7HJ United Kingdom
Phone Number: +44 1562 732290

iQ18B/iQ15B/iQ15/iQ12/iQ10/iQ8This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
report this ad

This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.Important information:Changes or modifications to the equipment not expressly approved by MUSIC Tribe can void the user’s authority to use the equipment.

References

[xyz-ips snippet=”download-snippet”]