Package Contents

Installation Requirements

  • Drill, 6 mm drill bit, and Phillips screwdriver (wall-mounting)
  • For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable

IMPORTANT: Although the cabling can be located outdoors, the EdgeSwitch itself should be housed inside a protective enclosure. WARNING: To reduce the risk of re or electric shock, do not expose this EdgeSwitch to rain or moisture.

Hardware Overview

Management Power/Link LED
Off No Power/No Link
Amber After bootup, the LED indicates power. After an initial link is established, the LED indicates a 10/100 Mbps connection. If the link terminates, the LED turns off until a link is re-established. If the unit reboots, the LED will again indicate power until a link is established.
RJ45 PoE LED (Ports 1 – 5)
Off No Power over Ethernet
Green 24V Power over Ethernet
RJ45 Speed/Link/Act LED (Ports 1 – 5)
Off No link
Amber Link established at 10/100 Mbps
Amber Flashing Link activity at 10/100 Mbps
Green Link established at 1000 Mbps
Green Flashing Link activity at 1000 Mbps
Management Port
10/100 Mbps port used to access the EdgeSwitch Configuration Interface.
USB Port
Reserved for future use.
RJ45 (Ports 1 – 5)
Reset Button
To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the unit is powered on.
Power
Connect the included Power Adapter to the Power port.

Hardware Installation

Place the EdgeSwitch on a benchtop or other surface. WARNING: FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARDS.KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW.

Wall-Mounting

Grounding the EdgeSwitch (Optional)

The EdgeSwitch is grounded through the Power Adapter; however, you can add optional ESD grounding for enhanced ESD protection.

Connecting Power

Connecting Ethernet

Note: PoE is disabled by default on all numbered ports and is not available on the Management port. To enable PoE on the appropriate ports, use the Ports tab in the Configuration Interface.

Accessing the Conguration Interface

Connect to the Conguration Interface:

  1. Ensure that your computer (or another host machine) is connected to the Management port on the EdgeSwitch. Note: By default, you can configure the EdgeSwitch via any port; however, we recommend the Management port. (Access to the Conguration Interface can be limited to the Management port only. You can configure this setting on the Device tab.)
  2. Configure the Ethernet adapter on your host system with a static IP address on 192.168.1.x subnet (e.g., 192.168.1.100).
  3. Launch your web browser. Type https://192.168.1.20 in the address eld. Press enter (PC) or Return (Mac).
  4. Enter ubnt in the Username and Password fields. Click Login.

The Conguration Interface will appear and allow you to customize your settings. You can enable PoE on the Ports tab.You can also manage your device using the Ubiquiti® Network Management System. UNMS™ lets you conjure, monitor, upgrade, and back up your devices using a single application.

Specifications

ES 5XP
Dimensions 197 x 87.5 x 27.3 mm (7.76 x 7.28 x 1.61″)
Weight 250 g (8.82 oz)
Power Input 24VDC, 2.5A Power Adapter (Included)
Max. Power Consumption 60W
PoE Out Voltage Range 22-24VDC
Max. PoE Wattage Per Data Port 11.5W
ESD Rating ±24 kV Air/Contact
PoE Method Passive
Button Reset
USB Port 2.0 Type-A (Reserved for Future Use)
Processor MIPS 24K, 400 MHz
System Memory 64 MB
Code Storage 8 MB
PoE Configurable Per Port Management Port N/A
LEDs Per PortManagement PortData Ports Power/LinkPoE, Speed/Link/Activity
Networking InterfacesManagement PortData Ports (1) 10/100 Ethernet Port(5) 10/100/1000 Ethernet Ports
Operating Temperature -25 to 55° C(-13 to 131° F)
Operating Humidity 90% Noncondensing
Certifications CE, FCC, IC

Safety Notices

  1. Read, follow and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

WARNING: Failure to provide proper ventilation may cause re hazard. Keep at least 20 mm of clearance next to the ventilation holes for the adequate arrow. WARNING: To reduce the risk of re or electric shock, do not expose this product to rain or moisture. WARNING: Do not use this product in a location that can be submerged by water.WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment, or pose is a hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualied service technician.
  3.  This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.c. Contact a qualied electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.d. Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.e. Protective bonding must be installed in accordance with local national wiring rules and regulations.

ui.com/support/warrantyThe limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

ComplianceFCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2.  This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada

CAN ICES-3(A)/NMB-3(A)

Australia and New Zealand

Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.

CE Marking

CE marking on this product represents the product is in compliance with all directives that are applicable to it.

WEEE Compliance StatementDeclaration of ConformityOnline Resources

report this ad

© 2020 Ubiquiti Inc. All rights reserved.

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by