UBIQUITI UDM-Pro UniFi Dream Machine Pro User Guide
Table of Contents
UDM-Pro Quick Start Guide
Package Contents
System Requirement
Either of the following is required:
iOS or Android™ Mobile Device with UniFi Network App Installed
Web Browser: Google Chrome (Other browsers may have limited functionality)IMPORTANT: We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power.
Hardware Overview
Bootup Animation
Initializing.
Location Animation
This indicates that you clicked Locate in the UniFi Controller software. The software will also display the location of the device on the map.
HDD LED
Flashing White
Indicates Read/Write Activity
Steady Amber
Indicates HDD Error
RJ-45 Speed/Link/Activity LED (Ports 1 – 9)
Off
No Link
Amber
Link Established at 10/100 MbpsFlashing Indicates Activity
Green
Link Established at 1 GbpsFlashing Indicates Activity
SFP+ Speed/Link/Activity LED (Ports 10 – 11)
Off
No Link
Green
Link Established at 1 GbpsFlashing Indicates Activity
White
Link Established at 10 GbpsFlashing Indicates Activity
HDD Bay
Install a 3.5″ or 2.5″ HDD (not included) to use the device as an NVR for UniFi Protect.
RJ45 LAN (Ports 1 – 8)
The RJ45 ports support 10/100/1000 Ethernet connections. By default, they are set to DHCP Server with the fallback IP address, 192.168.1.1/24.
RJ45 Internet (Port 9)
The RJ45 port supports a 10/100/1000 Ethernet connection. Set to DHCP Client by default.
SFP+ Internet (Port 10)
The SFP+ port supports a 1/10G Ethernet connection. Set to DHCP Client by default.
SFP+ LAN (Port 11)
The SFP+ port supports a 1/10G Ethernet connection. By default, it is set to DHCP Server with the fallback IP address, 192.168.1.1/24.
Reset Button
Resets to factory defaults. The device should be running after bootup is complete.Press and hold the Reset button for about 10 seconds until the display indicates that the device has reset itself. After a few seconds, the LED will turn off, and the device will automatically reboot.
USP RPS LED
USP Connect DC Input
Reserved for future use.
Power Port
Connect the included Power Cord to the Power port.
Installation Requirements
Phillips screwdriver
Standard-sized, 19″ wide rack with a minimum of 1U height available
For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with an industrial-grade shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable Note: Although the cabling can be located outdoors, the UDM-Pro itself should be housed inside a protective enclosure.
Installing an HDD
Ensure the device is powered off before you install the 3.5″ or 2.5″ HDD (not included).
Enable Bluetooth on your mobile device and use the UniFi Network app.
Use a computer connected to the UDM-Pro on a LAN port. Go to “Chrome Instructions”.
UniFi Network App
Follow the on-screen instructions.
Chrome Instructions
Use the Chrome web browser to set up your device.
Ensure that your host system is on the same Layer 2 network as the UDM-Pro.https://setup.ui.com
Follow the on-screen instructions of the Setup Wizard.After you run the UniFi Setup Wizard, a login screen will appear for the UniFi Network Controller management interface. Enter the Username and Password that you created in the UniFi Setup Wizard. Then click Sign in.
You can manage your network and view network statistics using the UniFi Network Controller management interface. For information on using the UniFi Network Controller software, refer to the User Guide located on our website at: ui.com/download/unifi
Specifications
UDM-Pro
Dimensions
442.4 x 43.7 x 285.6 mm (17.42 x 1.72 x 11.24″)
WeightWith Mount Brackets
3.90 kg (8.60 Ib)3.99 kg (8.80 Ib)
Interfaces NetworkingManagement
(8) 10/100/1000 RJ45 LAN Ports(1) 10/100/1000 RJ45 WAN Ports(1) 1/10G SFP+ LAN Port(1) 1/10G SFP+ WAN PortEthernet In-Band (1) Bluetooth BLE
Max. Power Consumption
33W
Power Method
(1) Universal AC Input, 100 to 240VAC(1) RPS DC Input
Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in a location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
Electrical Safety Information
Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.d. Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.e. Protective bonding must be installed in accordance with local national wiring rules and regulations.
Limited Warranty
ui.com/support/warrantyThe limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area are likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.This radio transmitter has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: operation of the device.This radio transmitter has been approved by ISED Canada.
IMPORTANT NOTE
Radiation Exposure StatementThis equipment complies with radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
Country List
AT
BE
BG
CY
CZ
DE
DK
EE
EL
ES
FI
FR
HR
HU
IE
IT
LV
LT
LU
MT
NL
PL
PT
RO
SE
SI
SK
UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.The following applies to products that operate in the 5 GHz frequency range: Note: This device is restricted to indoor use only when operating in the 5150 – 5350 MHz frequency range within all member states.Note: All countries listed may operate at 30 dBm. BFWA member states may operate at 36 dBm. Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.Other countries listed may use the 5.8 GHz, frequency band.
WEEE Compliance StatementDeclaration of ConformityOnline Resources