US-16-XG Quick Start Guide

Package Contents

Installation Requirements

  • Phillips screwdriver (for rack- or wall-mounting)
  • Standard-sized, 19” wide rack with a minimum of 1U height available (for rack-mounting)
  • Use compatible ber SFP+ modules with the appropriate ber optic cabling. For information about compatible ber SFP+ modules, visit: community.ubnt.com/uni
  • For indoor applications, use Category 6A (or above) UTP cabling approved for indoor use.
  • For outdoor applications, shielded Category 6A (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable

Note: Although the cabling can be located outdoors, the UniFi Switch itself should be housed inside a protective enclosure.

System Requirements

  • Linux, Mac OS X, or Microsoft Windows 7/8/10
  • Java Runtime Environment 1.6 (1.8 or newer recommended)
  • Web Browser: Google Chrome (Other browsers may have limited functionality.)

Hardware Overview

1. System LED
Click here for detailed descriptions.
2. SFP+ Speed/Link/Act LED (Ports 1 – 12)
Off No Link
Green Solid: 1 Gbps Unk Established Flashing: Activity
White Solid: 10 Gbps Link Established Flashing: Activity
3. R145 Speed/Link/Act LED (Ports 13 -16)
Off No Link
Green Solid: 1 Gbps Unk Established Flashing: Activity
White Solid: 10 Gbps Link Established Flashing: Activity
4. SEP+ (Ports 1 – 12)
Hot-swappable SFP+ ports support 1 Gbps and 10 Gbps connections.
5. R145 (Ports 13 – 16)
R145 ports support 1 Gbps and 10 Gbps Ethernet connections.
6. Reset Button
This button serves two functions for the UniFi Switch:• Restart Press and release the Reset button quickly.

Console Port

7. Console Port
RJ45 serial console port for Command Line Interface (CLI) management. Use an 8145-toD89, serial console cable, also known as a rollover cable, to connect the Console port to your computer. Then configure the following settings as needed:•Baud rate 115200•Data bits 8•Parity NONE•Stop bits 1•Flow control NONE
8. DC Input
The 48/24VDC input can connect a redundant or stand-alone DC power source (not included) with minimum power 56W, 57 to 20V.Note: You can use the redundant DC power source as a hot spare; if the Internal AC/DC power supply no longer provides power, the UnIFI Switch will switch to the DC power source without interrupting its operation.9. Power Port
Connect the included Power Cord to the Power port.

Hardware InstallationMounting in a Rack (Optional)

1.

2.

 

Connecting Power

1.

2.

Connecting SFP+

1.

2.

3.

For information about compatible ber SFP+ modules, visit: community.ubnt.com/uni

Connecting RJ45

1.

2.

Software Installation

Download and install the latest version of the UniFi Controller software at ui.com/download/uni and follow the on-screen instructions.Note: If you already have UniFi Controller v5.4 or higher installed, go to the section, Adopting the UniFi Switch.After you have installed the software and run the UniFi Installation Wizard, a login screen will appear for the UniFi Controller management interface. Enter the username and password that you created and click Sign In.

To adopt the UniFi Switch, proceed to the section, Adopting the UniFi Switch.For information on conjuring and using the UniFi Controller software, refer to the User Guide on the website: ui.com/download/uni

Adopting the UniFi Switch

  1. From the UniFi Controller dashboard, click Devices in the left menu bar.
  2. Locate the UniFi Switch in the list of devices under the Model column. Click Adopt.
  3. The System LED on the UniFi Switch will turn blue to confirm that it has been successfully adopted.
    Dimensions 443 x 221 x43 mm (17A4x 8.70 x 1.691
    WeightWith Mount Brackets 2.67 kg (5.89 Ib)2.76 kg (6.04 Ib)
    Total Non-Blocking Line Rate 160 Gbps
    Max. DC Power Consumption 36W(excludes SFP/SFP+ modules)
    Power MethodACDC 100-240VAC/50.60 Hz Universal Input48VDC/24VDC
    Power Supply AC/DC, Internal, 56W DC
    Supported Voltage Range 100 to 240VAC 57 to 20VDC
    Rack-Mount Yes, 1U High
    ESD/EMP Protection Ain ±24 kV, Contact ± 24 kV
    Shock and Vibration ETSI300-019-1A Standard
    LEDs Per PortSFP+ Data Ports R145 Data Ports Speed/Link/ActivitySpeecUUnk/Activity
    InterfacesNetworking InterfacesManagement Interface (12) 1/10 Gbps SFP+ Ethernet Ports (4) 1/10Gbps R145 Ethernet Ports(1) R145 Serial Port Ethernet In-Band
    Operating Temperature -5 to 40° C (23 to 104° F)
    Operating Humidity 5 to 95% Nonoondensing
    Certifications CE, FCC, IC

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

WARNING: Failure to provide proper ventilation may cause re hazard. Keep at least 20 mm of clearance next to the ventilation holes for the adequate arrow.WARNING: To reduce the risk of re or electric shock, do not expose this product to rain or moisture.WARNING: Do not use this product in a location that can be submerged in water.WARNING: Avoid using this product during an electrical storm. There may be a remote risk of

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment, or pose is a hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.d. Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.e. Protective bonding must be installed in accordance with local national wiring rules and regulations.

Limited Warranty

ui.com/support/warrantyThe limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

ComplianceFCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area are likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada

CAN ICES-3(A)/NMB-3(A)Australia and New ZealandWarning: This equipment is compliant with Class A of CISPR 32. In a residential environment this

CE Marking

CE marking on this product represents the product is in compliance with all directives that are applicable to it.

WEEE Compliance StatementDeclaration of ConformityOnline Resources