ULINE S-15286 Service Kit For L-Bar Sealer Instruction Manual
OPERATING INSTRUCTIONS
Changing Parts
Replacing Heating Element Wire
REMOVE PLUG FROM OUTLET BEFORE INSTALLATION
- Remove plastic cover from front post.
- Remove Teflon® tape on both the top and bottom sealing arms.
- Remove screw attaching heating element to post, located under plastic cap.
- Remove heating element.
- Remove rear top cover plate to expose rear post.
- Attach new heating element to front post with screw.
- Feed heating element through channel.
- Use flathead screwdriver to compress spring on rear post.
- Attach heating element to rear post.
- Replace top cover.
- Replace plastic cover on front post.
- Cut new Teflon® tapes in half to create four, 18” Place two on the top sealing arms and two over the bottom sealing wires.
[xyz-ips snippet=”download-snippet”]