Meet The New StandardIn Non-Contact, High Voltage DetectionThe Amprobe TIC 300 PRO with VolTect™

99 Washington StreetMelrose, MA 02176Phone 781-665-1400Toll-Free 1-800-517-8431Visit us at www.TestEquipmentDepot.com

AMPROBE

TIC 300 PRO with VolTect’ Quick Start Guide

On/OffWhen the TIC 300 PRO is activated. the blue LED and audible alert will pulse at a slow rate. approximately twice per second.

LOW Range Setting

  1. Push the ON/OFF button to turn the unit ON. The unit will default to the high voltage setting when powered up.
  2. Push the LOW range button, and the unit is ready for low voltage detection.
  3. Place the probe tip near. but not touching. the low (<10001f) voltage source. See the bottom table for range details.
  4. If voltage is present. the blue LEDs and audible alerts will pulse at an increased rate.

Low Range Setting

Voltage (Phase to Ground) Detection Distance (from the energized line)Average
30 V 1.5″
75 V 6.5″
100 V 8.5″
120 V 10″
220 V 1’1″
500 V 1’7″
1000 V 2’10”
1500 V 7.9″

Self-testThe TEST button should be used to ensure the tool is operational. The TEST function will cause the blue LEDs and audible alerts to pulse at a continuous rate on either LOW or HIGH range settings.

HIGH Range Setting(> 1500V and <122 kV) (Must use with TIC 410A Hot Stick Attachment)

  1. Push the ON/OFF button to turn the unit ON. The unit will default to the high voltage setting when powered up.
  2. Approach the probe tip near, but not touching, the high voltage conductor. See the bottom table for range details.
  3. If voltage is present, the blue LEDs and audible alerts will pulse at an increased rate.

High Range Setting

Voltage(Phase to ground) 1 Detection DistanceAverage
1.5 kV 1’2′
2.0 kV 2′ 5′
4.0 kV 3″
10.0 kV 6’3″
25.0 kV 9’4′
50.0 kV 13’0′
75.0 kV 14’8′
100.0 kV 19’8′
122.0 kV 22’0′

For complete information on the TIC 300 PRO, visit amprobe.com

Meet TheNew StandardIn Non-Contact, HighVoltage Detection

The Amprobe TIC 300 PRO with VolTecr Non-Contact High Voltage Detector

Key Features

  • Bright visual and loud audible voltage indication
  • Self-test verifies that the tool is operational
  • Push-button functionality for ease of use with PPE gloves
  • Intrinsically safe and MSHA certified
  • Low range setting: 30V ac g 1,500V ac
  • High range setting: 1,500V ac g 122,000V ac (must use with TIC 410A Hot Stick Attachment)

Test Equipment Depot – 800.517.8431 – 99 Washington Street Melrose, MA 02176TestEquipmentDepot.com4159996 B