WANPTEK DC Power Supply Instruction Manual

WANPTEK DC Power Supply

Safety Summary

Welcome to use the adjustable program Rcontrolled DC stable voltage power supply (hereinafter referred to as the power supply) produced by Shenzhen Solid Measurement Electronic Technology Co., Ltd. Before use, please read this manual, especially about safety, to avoid personal injury, or cause damage to the power supply and other electronic equipment connected to the power supply. This manual contains important safety instructions that must be followed for the operation and storage environment of the WPS/APS series adjustable program controlled DC regulator.

Whan you get a new power supply, you need the necessary checks to ensure the instrument.

  1. Check if there is any damage caused by transportation.
  2. Check whether the accessories are complete and complete.
  3. Before powering on, be sure to check whether the product meets your actual input voltage.
  4. Check whether the output voltage and current of the machine are normal.

If any problems are found in Ula above inspection, please contact the dealer in time.

Product Overview

The WPS /APS series Is a digital display programmable switch DC voltage stabilization supply to simultaneously display voltage, current and power. This power supply Is widely used for product aging, R & D testing, school and production line use, Its output voltage and output current are presently adjusted by the encoder knob and can be continuously adjustable between O end nominal values. The stability and ripple coefficient of the power supply are very good, with short- circuit protection, overpressure protection, overcurrent protection, overtemperature protection and other protection circuits. The product design is beautiful, convenient for operation, and can work for a long time. This computer is equipped with USB fast charging interface; computer PC-terminal software control function. Popular by the majority of users.

Product parameters

Model List

WPS-Series Model

Product model Output voltage Output current Output power
WPS305HIB 0-30V                       0-5A 150W
WPS3010HIB 0-30V                      0-10A 300W
WPS605H/B 0-60V                       0-5A 300W
WPS1203HIB 0-120V 0-3A 360W
WPS1602HIB 0-160V 0-2A 320W
Product Size Produd Size: H 220mm X Width 90mm X H 145mm
Package dimensions Package Size: 300mm X Width 140mm X H 200mm
Product Weight Net product quantity: 1.6Kg, gmu, weight: 1.8Kg

APS-Series Model

Product model Output voltage              Output current

I

Output power
APS305H 0-30V                       0-SA

I

150W
APS3010H 0-30V                      0-10A

I

300W
APS605H 0-60V Qm5A 300W
APS1203H 0-120V 0-3A 360W
APS1602H 0-160V          I                  0-2A 320W
Product Size Produc:t Size: H 220mm X Width 90mm X H 145mm
Package dimensions Package Size: 300mm X Width 140mm X H 200mm
Product Weight Net product quantity: 1.6Kg, gross weight: 1.8Kg

Appearance description of the WPS model

Front panel

  1. Power supply switch
  2. Voltage regulation encoder
  3. Current regulation encoder
  4. Output switch
  5. Voltage display
  6. Current display
  7. Power display
  8. Constant pressure status indicator
  9. Constant current status Indicator
  10. OCP short circuit indicator
  11. Output indicator
  12. Positive output terminal+
  13. Negative output terminal-
  14. Ground terminal
  15. USB fast charge InterfaceREAR PANEL
  16. Cooling fan
  17. AC input power outlet
  18. Fuse box
  19. USB host computer interface
  20. AC Input voltage selector switch

Appearance description of the APS model

Front panel

  1. Power supply switch
  2. Voltage regulation encoder
  3. Current regulated encoder
  4. Output switch
  5. Voltage display
  6. Current display
  7. Power display
  8. Constant pressure status indicator
  9. Constant current status Indicator.
  10. Positive output terminal+
  11. Negative output terminal-
  12. Ground terminal
  13. USB fast charge interface
  14. Cooling fan
  15. AC in put power socket
  16. Fuse box
  17. USB host computer interface
  18. AC Input voltage selector switch
  19. OCP short circuit protection switch
  20. M1-M3 storage button

Panel function description

  1. Power switch Used to turn the power on or off.
  2. VOLTAGE voltage regulation encoder: Used to adjust the setting voltage. Tum clockwise to increase the value; tum counterclockwise to decrease. the value. Presa the coding switch to shift to the left 3 seconds after the voltage setting operation Is completed, the flashing stops, and !he current setting value is stored.
  3. CURRENT current regulating encoder: Used to adjust the setting current Tum clockwise to increase the value; tum c:ounten::lockwise to decrease the value. Press the coding switch to shift to the left. 3 seconds after the current setting operation is completed, the flashing stops, and the current setting value is stored. WPS models also have: long press to enable/disable short-circuit protection
  4. Output switch: Used to turn on or off the output of the power supply. When the short-circuit protection alarms, press to release the alarm and enter the closed output state.
  5. Voltage display: Used to display the voltage setting value or output value. When setting the voltage, It displays the setting voltage value. When the power output is turned on, the actual output voltage value is displayed.
  6. Current display: Used to display the current setting value or output value. When setting the current, it displays the setting current value. When the power output is turned on, the actual output current value is displayed.
  7. Power display: Used to display the output power.
  8. CV constant voltage status indicator: The CV indicator lights up, and the machine Is working In a constant voltage state.
  9.  Constant current status indicator: The CC indicators lights up and the machine la working In a constant current state.
  10. OCP short circuit indicator: Used to prompt whether the OCP function Is enabled. light up to Indicate that the OCP function Is enabled.
  11. Output indicator: The Indicator light is on to Indicate that the power output Is on, and the Indicator light is off to Indicate that the power output is off.
  12. Positive output terminal: The•+• positive output terminal is used to connect the positive pole of the load device.
  13. Negative output terminal: The”-” negative output terminal is used to connect the negative pole of the load device.
  14. Grounding boll: Used for grounding.
  15. USB Independent fast charging Interface: This machine supports USB fast charging function, built-in fast charging protocol chip, output power up to 18W. It can provide fast charging for mobile phones, PADs, power banks and other devices with fast charging functions. Automatically adjust the output voltage end current according to the fast charging protocol of1he charged device. When electronic devices that do not have the fast charging function are used, they will be charged according to the standard 5V.
  16. Cooling fan: Used for chassis heat dissipation, temperature control type, start the fan when the temperature that needs heat dissipation is reached.
  17. Input power socket: AC power Input socket
  18. Fuse box: Used to store the fuse for easy replacement.
  19. USB host computer Interface: II is used to conned ‘lo the upper computer of the computer to realize the remote control of the power supply. The upper computer software can be downloaded from the official website. Download link: wanp’lek.com
  20. AC input voltage selection switch:This machine supports AC115V or AC230V dual-voltage Input work, which needs to be switched by this switch.
  21. OCP short circuit protection switch: APS model: Press the OCP button to enable/disable the OCP short-circuit protection function. After this function is enabled, the indicator will light up. When the load is short-circuited, the machine will stop output and give an alarm. Press the output output button to release the alarm and enter the dosed output state . WPS model: Long press the current knob to enable/disable the OCP short-circuit protection function. After this function is enabled, the indicator will light up. When the load is short-circuited, the machine will stop output and give an alarm. Press the Output button to release the alarm and enter the shutdown output status.
  22. Storage button (applicable to APS models) The APS model has 3 groups of memory functions for easy storage and recall of commonly used parameter. Long press any button of M1-M3, the machine will memorize the currently set voltage and current value, short press any button of M1-M3, the machine will recall the previously stored voltage and current value. WPS model does not have this function!

WARNING: When using this product, please make sure that the power cord is well grounded. If the power socket has no ground wire, Wires can be used to connect the casing of the machine to the ground. Good grounding can effectively prevent machine leakage and reduce output ripple Interference.

Requirements

  1. Please use a power cord that meets the pow11r requirements of this product
  2. Before use, the power supply must be grounded reliably, and the weak leakage current caused by the Internal anti-electromagnetic interference circuit of the power supply should be led to the ground, otherwise false leakage will occur, which may cause damage to the load equipment or cause the power supply to resist Interference D8Cf98se in ability.
  3. When using this power supply to charge reusable batteries (such as lead-acid batteries), you must ensure that the positive and negative poles of the power supply m1 correctly connected to the positive and negative poles of the battery. If they are connected reversely, the Internal rectifier components of the power supply may be burned out , Or damage the load equipment.
  4. It Is strictly forbidden to use this product In an environment with flammable, explosive materials, humidity, and corrosive gas.
  5. When this product Is working, It will generate heat, especially under full power usage. There & before, please use this product in an environment with good ven1ilation and heat dissipation, and ensure that there are no other obstacles In the vicinity of the product’s cooling fan and vents.
  6. When using this power supply, please select an output wire with sufficient wire diameter according to the output current of the product. The connection area between the wire and the power supply, the wire and the load equipment is large enough, the contact surface is clean and free of corrosion, and the connection must be firm to avoid heat damage to the terminal or load equipment, which may cause a fire In severe cases.
  7. If you encounter product use problems and quality problems, please consult our after-sales personnel. If n9C88Sary, the power supply must be sent to our company for maintenance. Because there Is high voltage Inside the machine (even if the power is off, the circuit will still have high voltage for a certain period of time), please do not repair or modify It by yourself, otherwise, It may cause the expansion of the fault or cause personal Injury.
  8. Please confirm the AC voltage allowed by the machine first. This machine can realize two kinds of AC voltage Input through the switch on the rear panel: AC 230V±10% or AC 115V±10% (when [IllB] ‘”230V” appears, allowable input voltage: AC 230V±10%, when IJOO “11 fN” appears When, allowable input voltage: AC 115±10%).

Warning: Wrong AC voltage input will cause serious damage to the machine. Please confirm the input voltage value required by the machine.

Main features of the product

  1. Constant voltage and constant cu1Tent automatic switching function. Constant voltage value and constant current value can be preset with coding $Witch, which i$ convenient to Use.
  2. There Is a separate power output switch button, through which the power output can be turned on or elf conveniently. When the output is stopped. the screen displays the set voltage value and set current value, which is convenient for setting.
  3. Short-circuit protection alarm function (OCP). When this function is enabled, the power supply will stop outputting when the load equipment Is short-circulated, and there will be a buzzer sound and OCP characters to Indicate. After the external short circuit is released, press the output button to release the alarm or restore the output It can effectively protect the load equipment.
  4. The selling voltage, setting current, actual voltage and actual current are all displayed in four digits.
  5. The use of low-noise, temperature-controlled cooling fans to ensure that the power supply works within the appropriate temperature.
  6. This power supply has an overheating protection function. When the Internal temperature of the power supply reaches 75 degrees or more, the power supply will be forbidden to output to avoid damage to the machine due to overheating.
  7. The constant voltage and constant current values are automatically memorized when the machine is turned off (or power down), end the set value at the last shutdown (or power down) will be used when the machine is turned on again.

Method of operation

  1. Power on: Press the POWER button to tum on the power, and the screen will display the voltage and current values that were set when the machine was turned off last time.
  2. Voltage setting: Regardless of whether the power supply is in the output slate, you can Wm the “VOLTAGE” coding switch to set the voltage. When It enters the voltage setting state, The currently set “bit” is prompted by flashing; tum clockwise to increase the value, and tum counterclockwise to decrease the value. Presa the coding switch to shift to the left. 5 seconds after the voltage setting operation Is completed, the flashing stops, and the current setting value is stored.
  3. Currant setting: Regardless of whether the power supply Is In the output state, you can rum the “CURRENT” coding switch to set the current. When entering the current setting slate, the currently set “bit will flash in a flashing way, tum clockw1se to Increase the value, and tum counterclockwise to decrease the value . Press the coding switch to shift to the left 5 seconds after the current setting operation is completed, the flashing stops, and the cul1’8nt setting value is stored.
  4. Output switch: Short press the “Output” button on the panel, you can switch the power output and turn off’.
  5. OCP short circuit protection: WPS model: Presa the “Current coding switch for 3 seconds to tum on (or tum off) the OCP short-circuit protection alarm function. APS model: Press the “OCP” button to tum on (or tum off) the OCP short-circuit protection alarm function. After the OCP protection alarm function is turned on, when the machine detects a short circuit or over current in the external load, the machine will stop output and give an alarm to effectively protect the external load. In the OCP short-circuit alarm state, short press the Output key to release the alarm state and enter the closed output state.

Examples of use:Set the power supply 10 12V and the current to 3A The operation Is as follows:

  1. Turn on the power switch,
  2. Rotate the “VOLTAGE” coding switch to preset the voltage 1o “12.00”V.
  3. Rotate the “CURRENT” coding switch to preset the current to “3.000”A.
  4. Connect the output terminals on the panel of the machine to the load equipment correctly and firmly with appropriate wires.
  5. Short press the “Output’ output button, the Indicator light will light up, and the machine will output normally.
  6. If you need to enable the short-circuit protection (over-current protection} function, you can press the -OCP” button at any time (WPS model, long press the “CURRENT” coding switch) to enable this function.

Note:

  1. In the actual CV operation, If the load resistance decreases and the output current increases to the set current value, the power supply will automatically switch to CC mode. When the load resistance continues to decrease, the current will remain at the current setting Value, the voltage drops proportionally {l=V/RJ. At this lime, increase the load resistance or increase the current setting value to restore the CV output state.
  2. The machine Judges whether there Is a short circuit In the output, based on whether the output current is greater than the current set by the user. Therefore, when the OCP short -circuit protection function is enabled, the machine cannot be used in constant current mode.

Connect load equipment

  1. Rotate counterclockwise to loosen the terminal knob
  2. Put the output wire terminals Into the terminal screw according to the positive and negative poles
  3. Tum clockwise to tighten the terminal knob
  4. Firmly connect !he other end of the wire with the positive and negative poles of the load device.

Note: Incorrect connection may cause damage to the power supply and the load connected to the power supply. When connecting a battery load, do not connect the “+” and “-” poles reversely, as this may damage the power supply.

Constant voltage/constant current characteristics:  

The working characteristic of this series of power supplies is constant voltage/constant current automatic conversion type, which can automatically change between constant voltage and constant current states with the change of load. The intersection point between constant voltage and constant current is called the conversion point. For example, If the load makes the power supply work in a constant voltage mode, it outputs a constant voltage. A:s the load increases, the output voltage will remain stable and the output current will increase. When the current value reaches the set current limit value, the pawer supply will automatically switch to constant current mode. The output current remains stable, and the output voltage decreases proportionally with the further increase of the load. The conversion between constant voltage and constant current is indicated by the LED on the front panel. The CV indicator light is on when the voltage is constant, and the CC Indicator light Is on when the current is constant.

System settingsPress and hold the Output button for 5 second$ to enter the system setting function. According to the needs of use, the machine can be set by default. The system default setting Items Include:

  1. The ID of the machine.
  2. The J>OW6I’ supply output status.
  3. Screen brightness.
  4. Buzzer switch.
  5. Serial communication baud rate.
  6. Set the size of the serial port data.After entering the system settings, tum the voltage encoding switch to change the default parameter of the current project; press the voltage encoding switch to switch to the next Item, If you have switched to the last Item (item 6), click the voltage encoding switch again, the machine will Save the parameters and exit the setting state. If any other key is pressed during the parameter setting process, the setting state will be exited and the parameter setting will not be saved.

The specific setting items and parameter meanings are shown in the following table:

Serial

number

project parameter meaning Defaults
1 Native ID 1-4 Specify the number of this machine in the network 1
 

2

Output

default state

0 When the Power is turned on, the OUT output is turned off  by default  

0

1 When the power Is turned on, the OUT output

is turned on by default

 

3

Screen

brightness

0 Low brightness  

0

1 high brightness
 

4

 

Buzzer mute

0 No beeps  

0

1  

With beep

 

 

5

 

 

Communication baud rate

1 2400  

 

1

2 4800
3  

9600

4 19200
 

6

Communication

size end Ian setting

0 Small end structure  

0

1  

Big-endlan structure

Remote operationThis product can be equipped with a communication module (optional) to realize remote operation. The following describes how to realize remotes operation and control the output of power supply.Instructions:

  1. Use a USS cable to connect the power supply to the PC. You can also use a different conversion data cable to realize the use to RS232/485 Interface.
  2. Select the correct communication port and communication baud rate on the PC interface. After the receive” and “send” signals on the software interface flash normally, the machine is connected to the PC normally, and the power supply can be controlled through the software interface.

Fuse replacementIf the fuse blows, the machine will stop working. It is necessary to find out and correct the cause of the blown fuse, and then replace It with a fuse of the same specification.Fuse replacement method

High voltage danger: For effective safety protection, it is only limited to replacing the fuse of a specific specification. Before replacing the fuse, you must tum off the power and unplug the power cord from the power socket.

Product Maintenance

  1. When the machine 18 not In use, please disconnect the power supply.
  2. Unplug the power plug before cleaning the machine.
  3. Do not use solvents containing hydrocarbons, chlorides or similar, nor use detergents containing abrasive Ingredients.

Product Warranty

  1. This product enjoys free maintenance service within one year from the date of purchase. Except In the following cases:
    1. Fall um to show the product warranty card:
    2. Failures caused by abnormal use, such as Improper human operation and Improper repair, modification or adjustment of the device:
    3. Consumable materials are not covered by the warranty:
    4. Natural disasters that are irresistible, such as floods, fires, earthquakes, etc.
  2. Repairs beyond the warranty period will be charged a repair fee, and the user will be responsible for the expense incurred due to the maintenance.

Packing List

  1. One complete machine;
  2. One power cord;
  3. A pair of output load lines;
  4. A copy of the Instruction manual;
  5. A copy of the warranty card certificate;

common problemPower does not tum on Check whether the power cord has AC power and whether the fuse is intact.No power outputCheck whether the output button is turned on and whether the wire is in good conduction. Whether the voltage or current adjusts the output.What Is constant voltage mode (C.V)The power supply is constantly output according to the voltage set by the user, and the current will be output and supplied according to the actual needs of the load.What Is constant current mode (C.C)When the current required by the load exceeds the limit current value set by the user, the power supply will automatically switch to constant current mode. At this time, the current remains unchanged, and the voltage will be output and supplied according to the needs of the load.The power supply cannot be output according to the current sat by the user currant limit value set by the userThe current value set by the user refers to the maximum limit current value that the power supply is allowed to output, and the actual output current value is supplied according to the actual needs of the load, but will not exceed the.Shenzhen Guce Electronic Technology Co., Ltd.Address: Building F, Jinhengrun Science and Technology Park, Fucheng, Longhua District, ShenzhenPhone:0755-82736331http//www.wanptek.com

[xyz-ips snippet=”download-snippet”]