Whynter Elite D-Series Portable Dehumidifier With Pump #RPD-711DWP Instruction Manual

WHYNTER ELITE D–SERIES ENERGY STAR 70 PINT PORTABLE DEHUMIDIFIER WITH PUMPModel # : RPD-711DWPINSTRUCTION MANUAL

Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference.

DISPOSAL INFORMATION

Thank you for choosing the Whynter Portable Dehumidifier. Please follow the instructions provided in this user guide to obtain the very best performance from your dehumidifier. We trust that your Whynter dehumidifier will provide the performance and reliability that we stand for.Your Whynter dehumidifier is designed to remove moisture in the air by condensation removal and collecting the condensation water in the drain bucket or draining through a drain hose.Please keep this user manual in a safe place for future reference.

This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment.

Further information about the recycling of this product can be obtained from your local municipal authority.

SAFETY PRECAUTIONS

WARNINGTO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR PORTABLE DEHUMIDIFIER, FOLLOW THESE BASIC PRECAUTIONS:

  • Read all instructions before using the appliance.
  •  Never clean appliance parts with flammable fluids. The fumes can create a fire hazard. Do not use an excessively wet cloth, industrial solvents, and oil-based products to clean this appliance.
  • Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard.
  • Do not abuse, sit on, or stand on the appliance.
  • This appliance is not intended for use by persons (including children with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
  • Please dispose of packing materials properly.
  • Use the portable dehumidifier only for its intended function. This appliance is designed for household, noncommercial use only. Any other use will void the warranty.
  • To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas.
  • During installation, the power supply must not be excessively or dangerously bent or flattened.
  • Do not tamper with controls.
  • Make sure the power plug is placed fully and firm into the wall socket. If the wall receptacle you intend to use is not adequately grounded or protected by a time-delay fuse or circuit breaker, have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements.
  • Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire.
  • Make sure the power plug is clean before usage.
  • Do not turn this appliance on and off by plugging and unplugging. Always use the ON/OFF switch.
  • After turning the appliance off, please take the power plug out of the socket.
  • Make sure hands are dry when connecting the power plug. The appliance is equipped with a three-prong grounded plug on the power cord for your protection. Never modify, remove or attempt to repair the power plug yourself.
  • Do not repair, disassemble and/or modify the appliance by yourself.
  • Always turn off the appliance when cleaning the air filter, and transporting.
  • At the end of each season, all water must be drained from the appliance and air filter must be cleaned before storage.
  • Do not drink or use the water collected or drained from the appliance.
  • Do not remove the drain bucket during operation.
  • Transport the appliance in an upright position only, or leave it in an upright position for at least 2 hours before first use.
  • When positioning or moving the appliance, ensure that it is not turned upside down or greater than 45° or more off level.
  • This appliance must be installed in an area protected from the element, such as wind, rain, water spray, or drips.
  • Always place the appliance on even and hard and level surface that can support the unit when it is full of water.
  • Ensure objects are not obstructing the exhaust and air intake.
  • Never insert your fingers or other objects into the air intakes and air outlets.
  • Do not operate the appliance without the air filter.

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED

INTRODUCTION

How it WorksWhen the dehumidifier is started, the fan begins to pull moisture -laden air across the dehumidifying coils. The coils condense or draw moisture from the air, and air flows through the top louver into the room as dry, warm air. Moisture removed from air is collected in a drain bucket on the front of the dehumidifier.

The appliance is designed to operate between 41°F (5°C), and 96°F (35°C). The “Compressor” circuit has an automatic 3 minute time delayed start if the appliance is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. Make sure the drain bucket is fitted correctly otherwise appliance will not turn on.Energy Saving GuideThis Whynter dehumidifier is an Energy Star rated appliance. Follow the guide below can help to get the best performance and efficiency from your dehumidifier.

  • Do not cover the air intake and outlet.
  • Do not place the appliance in front of curtains or drapes – to ensure they do not obstruct the air intake.
  • Keep curtains, blinds or drapes closed during the sunniest part of the day.
  • Close all windows and doors.
  • Indoor relative humidity should ideally be kept between 35%RH and 60%RH depending on the ambient temperature.
  • Make sure the appliance is on a hard and level surface.
  • To prolong the compressor’s life, please wait at least 3 minutes before turning the appliance back on after shutting it off.
  • Inspect and keep the air filter clean by cleaning regularly.
  • Perform routine maintenance.

PARTS AND CONTROLS

Power Cord Buckle InstallationFor easy storage, install the power cord buckle to the rear of the unit. Once installed, the power cord can be wrapped using the buckle for safe storage.

PARTS AND CONTROLS

1. Pump ButtonPress to activate the pump operation. The Pump indicator light will illuminate when water pump is in operation.Note: Make sure the pump drain hose is installed into the unit and the continuous/gravity drain assembly is removed from the unit before the pump operation is activated. The water pump function will start when the drain bucket is full.

2. Comfort ButtonPress to activate the Comfort Dehumidifying mode operation. The Comfort Dehumidifying indicator light will come on when this mode is selected. In this mode, the unit will automatically control the room humidity in a comfortable range of 45%~55% according to the room temperature. The humidity setting function is automatically disabled. To stop Comfort Dehumidifying operation, press the Comfort button and set the desired RH percentage value to resume normal peration.

3. Filter ButtonThe check filter indicator is a reminder to clean the air filter for more efficient operation. The filter light will illuminate after approximately 250 hours of operation. To reset after cleaning the filter, press the Filter button and the light will turn off.

4. Continuous ButtonPress to activate the Continuous dehumidifying operation. The Continuous indicator light will come on when this mode is selected. To stop continuous operation, press the Continuous (CONT.) Button and set the desired RH percentage value to resume normal operation.

Note: The Humidity Set Control Buttons will be disabled. The compressor will not stop unless the drain bucket is full, or is removed.

5. Turbo Button Press the Turbo button to engage Turbo Fan mode. The Turbo indicator light will come on when this speed is selected. Press the Turbo button again to set the unit to Normal Fan mode. The Turbo indicator light will turn off when Normal Fan mode is activated.

PARTS AND CONTROLS

5. Timer ButtonPress to activate the Timer delay feature, in conjunction with the Timer Control Buttons.

  • Timer Delay Switch OffWhen the appliance is ON, press the Timer button to activate Auto-stop function and the Timer OFF light will come on. Set the desired time delay OFF hours by pressing the and buttons. The time increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance switches off. To cancel the delayed switch off function, set the time to “00” or turn off the appliance.
  • Timer Delay Switch OnWhen the appliance is OFF, press the Timer button to activate Auto-start function and Timer ON light will come on. Set the desired time delay ON hours by pressing the and buttons. The time increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance turns on. To cancel the delayed switch on function, set the time to “00” or turn off the appliance.
  • Timer Delay Switch On and Off SequenceWhen the appliance is OFF, press the Timer button to activate Auto-start function and Timer light ON will come on. Set the desired time delay ON hours by pressing the and buttons. Once Timer Delay Switch On is placed, press the Timer button again to activate Auto-stop function and the Timer OFF light will come on. Set the desired time delay OFF hours by pressing the and buttons. When the delay time set has elapsed, the appliance switches off. To cancel the delayed switch off function, set the time to “00” or turn off the appliance.

6. Humidity /Timer Control Buttons

  • Humidity Set Control ButtonsThe humidity level can be set within a range of 35%RH(Relative Humidity) to 85%RH in 5% increments. For lower humidity level, press the button and set to a lower RH percentage value. For higher humidity level, press the button and set to a higher RH percentage value. Once the RH% is set, the set RH% will stay on the display for about 5 seconds then it will revert back to current RH%.
  • Timer Set Control ButtonsIf Timer Button is pressed, use the and buttons to set the Auto Start and Auto Stop time from 0.0 hour to 24 hours.

7. Power ButtonPress to turn the dehumidifier on and off

Energy SaverWhen the unit is running on normal operation, once the RH% is reached, the fan will still run continuously to avoid high start-up amperage which makes the unit energy-efficient . Please note that the fan may run continuously or shut off intermittently depending on the RH% and set humidity.

PARTS AND CONTROLS

Bucket Full IndicatorThe appliance will run continuously until the set RH% is reached or when the drain bucket is full. When the drain bucket is full, the Full indicator light will illuminate and the dehumidifier will stop operating. Remove the water in the bucket with two hands, then place the drain bucket back to it’s proper position and the machine will start operating again.

Auto Defrost IndicatorIn the event frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost is evaporated. This happens when the appliance is operating in low temperatures (less than 53°F or 12°C), which affects the efficiency of the dehumidifier. When this happens, the Auto Defrost light will turn on and the machine will go into periodic defrost mode automatically. Defrost time may vary. If the dehumidifier freezes up, turn the appliance off for few hours and then restart. The appliance will not operate satisfactorily if the room temperature is below 41°F

DisplayThe display screen shows a number of different indications depending on the selection function.

  • Shows the set % relative humidity level from 35%RH to 85%RH.
  • Once the RH% is set, the set RH% will stay on the display for about 5 seconds then it will revert back to current RH%.
  • Shows Auto Start and Auto Stop time from 0.0 hour to 24 hours.
  • After the option settings are completed, the display shows the approximate room humidity level in a range of 30%RH (Relative Humidity) to 90%RH .

Auto RestartIn the event of a power outage, appliance restarts at the previously set function mode and settings when power is restored (not applicable to Timer Function).

OPERATION INSTRUCTIONS

AIR FILTERS INSTALLATIONYour Whynter portable dehumidifier is equipped with a 2 in 1 silver-coated washable pre-filter combo. This washable pre-filter removes large particles such as dust, pet hair and dander. The silver coating is designed to kill bacteria in the air and control the growth of microbes, such as viruses, fungi and spores.WARNING: NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER

START OPERATION

  1. Ensure that the appliance is connected to the power socket.
  2. Make sure the drain bucket is placed in proper position.
  3. Make sure filter is installed. (Fig. 1)
  4. When the unit is turned on for the first time, if the bucket full lamp lights up, just pull out the drain bucket then push it back to the proper position. (Fig. 2)
  5. Set the relative humidity level RH% by pressing the and buttons. We recommend setting the RH% to at least 10% lower than the current RH%.

OPERATION INSTRUCTIONS

POSITIONING THE UNIT

  • This dehumidifier is intended for indoor residential applications only and should not be used for commercial or industrial applications.
  • Place the dehumidifier on a smooth, hard and level floor strong enough to support the appliance with a full bucket of water.
  • Do not attempt to roll the appliance over objects.
  • Avoid placing the appliance in an area where the temperature will fall below 53°F. The coils may become covered with frost and may reduce performance.
  • Do not place the appliance near clothes dryer, heater or radiator.
  • Shut all doors, windows and openings to your target dehumidifying space for maximum performance.
  • Allow at least 10” of air space on all sides of the appliance for good air circulation and 20” or more above the appliance.

NOTE:

  • Dehumidifiers working in a basement will have little or no effect on adjacent enclosed rooms such as closets, unless there is enough circulation of air in and out of the enclosed area.
  • If the appliance has been switched off and needs to be switched on again, allow approximately three minutes for the correct operation to resume.
  • Select a suitable location and make sure you have easy access to the electrical outlet.
  • Ensure the air filter and drain bucket are correctly installed before switching the appliance on.
  • Always be careful when moving the appliance with a full drain bucket.
  • Ensure that the safety requirements and warnings detailed in this user manual are followed when operating this appliance.

WATER DRAINAGE INSTRUCTIONS

Using a portable dehumidifier requires that collected water be emptied frequently. Draining water from this unit can be done in 3 different methods:

1. DRAIN BUCKET METHOD
  1. When the bucket is full, the Full indicator light will light. The compressor and fan will turn off, the Full indicator will light, and a P2 code will be displayed.
  2. It is recommended to turn the unit off before removing the drain bucket.
  3. Grip the left and right handles of the drain bucket securely and carefully pull out the drain bucket. Do not put the drain bucket on the floor because the  bottom of the bucket is not even which may cause the water to spill. See Fig.3 and Fig. 4.
  4. Remove the water from the drain bucket and replace it back to the dehumidifier. The drain bucket must be installed properly and securely seated for the dehumidifier to operate.
  5. The machine will restart when the drain bucket is restored in its correct position. If the unit was turned off prior to the removal of the drain bucket, press the Power button to restore operation.

NOTES:

  • When you remove the drain bucket, do not touch any inside parts of the unit. Doing so may damage the product and result to injury.
  • Be sure to push the drain bucket gently all the way into the unit. Banging the bucket against anything or failing to push it in securely may cause the unit not to operate.
  • If the pump filter drops when you remove the bucket (see Fig.5), you must reinstall the pump filter properly to the unit before replacing the drain bucket into the unit (see Fig.6).
  • Upon replacing the bucket, firmly push the bucket in place until it locks. There should be no gaps between the bucket and the dehumidifier.
  • When the drain bucket is removed, the unit will beep 8 times and the digital display shows Eb. Eb is an error code that indicates that the drain bucket is removed or not positioned correctly. Make sure that the drain bucket is properly installed and the in right position.

WATER DRAINAGE INSTRUCTIONS

2. CONTINUOUS / GRAVITY DRAIN METHODWater can be automatically emptied into a floor drain by attaching the 20” continuous/gravity drain hose to the continuous/gravity drain outlet. To use gravity to drain your portable dehumidifier, it must be installed on a level surface or at least 12 inches above the ground, on a sturdy table or shelf unit. When using the function of continuous/ gravity drainage, your drain hose must be placed horizontally below the drainage hole. Avoid uneven ground and folding the hose.

  1. Remove the continuous drain cover and then attach the 20” continuous/gravity drain hose. Make sure the hose is securely fastened to prevent leakage.
  2. Direct the drain hose toward a drain or other suitable drainage outlet. Make sure that there are no distortions with the hose that may stop the water flow. (See Fig. 7)
  3. Select the desired humidity setting and fan speed on the unit for continuous draining to start.

NOTE: When using continuous/gravity drainage setup, there may be some water collected in the water in the drain bucket

3. WATER PUMP METHOD

One of the key features of this dehumidifier is that it has a water pump that pushes water up or over a longer distance. Using this feature will enable your unit to run maintenance free.

NOTE: The water pump will ONLY engage when the drain bucket is full.

  1. Make sure the continuous/gravity drain assembly is removed from the continuous/gravity drain outlet and the plastic cover is installed.
  2. Insert the 16 ft. pump drain hose (included) into the bottom pump drain outlet (See Fig. 8), then lead the drain hose to a suitable drainage facility. Make sure that the hose is fully inserted to avoid water leakage and no kinks which will cause the water to stop flowing.
  3. Press the Pump button to activate the pump operation.NOTE: The water pump will ONLY engage when the drain bucket is full.
  4. The water pump may make some noise when it starts to work within the first 3 – 5 minutes. This is a part of the unit’s normal operation.
  5. Select the desired humidity setting and fan speed on the unit.

NOTE: The Pump Indicator Light will flash when there is a failure in the pump operation. Please turn off the unit and unplug the power cord and check the following points:

  • Clean the pump filter – remove the drain bucket from the unit, pull down the pump filter, and clean (See Fig. 9)
  • Check the pump drain hose for kinks or obstructions
  • Reinstall the pump filter and drain bucket properly. Turn on the unit. If the error repeats, call for service
  • Do not use this operation when the outdoor temperature is equal to or less than 32°F. Otherwise, water hose may be blocked as the water will turn to ice and cause the unit to fail. When the pump drain feature is not being used, remove the pump drain hose from the outlet.

MAINTENANCE

CAUTION: Always turn off and unplug the dehumidifier before cleaning

1. Cleaning the air grille and main unit

  • Use a damp cloth to wrap the main unit or use water and a mild detergent. Do not use bleach, chemicals or abrasives.
  • Do not splash water directly onto the unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
  • Use a vacuum attachment or brush to clean the air intake and outlet grilles.

2. Cleaning the bucket

  • Clean the bucket to prevent growth of mold, mildew and bacteria every two weeks.
  • Fill the bucket with clean warm water and add mild detergent to the water.
  • Dry thoroughly before reinserting the bucket to the main unit.NOTE: Do not clean the bucket in a dishwasher.

3. Cleaning the air filter

To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently, it is recommended to clean the air filter at least once every twoweeks.

  • Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt.
  • Rinse the air filter under warm or cold running water (no hotter than 100F.)
  • Dry thoroughly before reinserting the air filter.
  • Reinstall the air filter and replace bucket securely.

4. End of Season Storage

  • After turning off the unit, wait 24 hours before emptying the bucket to allow excess moisture to drain into the bucket.
  • Attach the power cord buckle.
  • Wrap the power cord using the power cord buckle.
  • Clean the main unit, drain bucket and air filter as detailed above.
  • Cover the unit with the original plastic bag that came with the unit or any appropriate dust cover.
  • Store the unit upright in a dry, well-ventilated place.

TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER

If you have respiratory problems, asthma and allergies, your Whynter Portable Dehumidifier is a great option for controlling moist environments. Creating dry air can keep indoor air pollutants at a more manageable level, especially when used in conjunction with an air purifier. Using your portable dehumidifier can help you save money in the long run because it uses relatively little power and can help furnaces and air conditioners operate more efficiently.

1. Excess moistureIndoor environments with excessive moisture can cause mold and fungus to thrive inside the walls and beneath the carpet. Many types of mold are potentially dangerous and can lead to health problems. This Whynter Portable Dehumidifier reduces the amount of moisture in the air inside a home, which makes it far more difficult for harmful mold to grow. This portable dehumidifier is also effective for a small area, such as a hallway or bedroom.

2. Respiratory problems or allergiesThis Whynter Portable Dehumidifier which is perfect for larger rooms or areas in your home, including a living room or family room. If your home is musty, you will want to use your portable dehumidifier, especially if you have respiratory trouble or allergies. This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your home has such underlying problems as a leaky foundation walls or inadequate ventilation or if you live in a humid area. By keeping the relative humidity indoors below 50 percent, you can keep allergy-inducing dust mites and mold from thriving.

3. BasementsIf you have a basement that is below-grade, you should use your Whynter Portable Dehumidifier. This dehumidifier will help you keep the moisture levels in your basement down to manageable levels. By doing this, you can help keep your indoor furnace operating efficiently and even help eliminate minor standing-water problems. Your portable dehumidifier also can help keep furniture and valuables dry, and it will help keep electronics in proper working order.

4. Humid climatesIn humid climates, such as areas near a beach or large body of water, this Whynter Portable Dehumidifier can help keep the environment in your home at a more comfortable level. While the actual temperature won’t be affected, you’ll sleep more comfortably and may actually save money, since your unit can keep the indoor humidity and, thus, your thermostat under control.

TROUBLESHOOTING 

Many common portable dehumidifiers problems are easily resolved. Try the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department.

TROUBLESHOOTING

Many common portable dehumidifiers problems are easily resolved. Try the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department.

ONE YEAR LIMITED WARRANTY

This WHYNTER portable dehumidifier is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your WHYNTER portable dehumidifier prove defective within one year from the date of purchase, return the defective part or appliance, freight prepaid (within two months of purchase; after two months to one year, customer will be responsible for freight cost to Whynter’s service department), along with an explanation of the claim to Whynter LLC. Please package the portable dehumidifier  arefully in its original packaging material to avoid damage in transit. Please retain the original box and packaging material. Under this warranty, Whynter will repair  or replace any parts found defective. This warranty is not transferable. After the expiration of the warranty, the cost of labor and parts will be the responsibility of the original owner of the appliance.

THIS WARRANTY DOES NOT COVER:

  • Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
  • Damage, accidental or otherwise, to the portable dehumidifier while in the possession of a consumer not caused by a defect in material or workmanship;
  • Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the instructions.
  • Damage to the finish of the case, or other appearance parts caused by wear.
  • Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
  • Freight and Insurance cost for the warranty service.

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIESCUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, OR LIMITATIONS ON   THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.  THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

To obtain service or information, contactWhynter LLC via email at or call866-WHYNTER.

Product contents and specifications may change without notice.Copyright © 2015 Whynter LLCWWW.WHYNTER.COM

Whynter Elite D-Series Portable Dehumidifier With Pump #RPD-711DWP Instruction Manual – Whynter Elite D-Series Portable Dehumidifier With Pump #RPD-711DWP Instruction Manual –

[xyz-ips snippet=”download-snippet”]