WORKHORSE BK005 5 & 7 Nozzle Boom Kit Instruction Manual

WORKHORSE BK005 5 & 7 Nozzle Boom KitBK005 & BK0075 & 7 Nozzle Boom KitInstruction Manual

  • 5 Nozzle Boom Assembly with 100-inch coverage
  • 7 Nozzle Boom Assembly with 140-inch coverage

* These boom kits are designed to be used with any sprayer with a pump capable of 2.0 GPM flow or more, that has a garden hose accessory port.

GENERAL INFORMATION

The purpose of this manual is to assist you in assembling, operating, and maintaining your Hitch Mount Boom Kit. Please read it carefully as it furnishes information which will help you achieve years of dependable trouble-free operation.

WARRANTY / PARTS / SERVICE

Workhorse products are warranted for one year from the date of purchase against manufacture or workmanship defects for personal or homeowner usage with proof of purchase. Workhorse products arewarranted for 90 days for commercial users. Any unauthorized modification of a Workhorse brand sprayer will void the warranty.Your authorized dealer is the best source of replacement parts and service. To obtain prompt, efficient service, always remember to give the following information: 1) Correct part description and partnumber. 2) Model number and a serial number of your sprayer.Part description and part numbers can be obtained from the illustrated parts list section of this manual.Whenever you need parts or repair service, contact your distributor/dealer first. For warranty work always take your original sales slip, or other evidence of purchase date, to your distributor/dealer.

ASSEMBLY INSTRUCTIONS

Tools required:1 – Phillips Screwdriver2 – 1/2” End Wrenches1 – 7/16” End Wrenches

OPERATION

(Recommended to be used with an LG25DSS or similar 2.0 GPM or greater spot sprayer.)Refer to your original spot sprayer operating instructions.Pressure may be regulated by opening or closing the valve located on the top of your tank. Refer to your original instructions, or see some common “Valve Operations” illustrated in this manual.Regularly inspect the suction supply screen on the inside of the tank. Flush with water to clear any accumulated debris.

CALIBRATION

Chemical product labels may show application rates in gallons per acre, gallons per 1000 square feet, or gallons per 100 square feet. The tip chart for your sprayer shows all three rates for your convenience.After determining how much mixed solution you are going to pray for your job, select the spraying pressure (PSI) and spraying speed (MPH)  needed.Current weather and terrain conditions must be considered when setting up the sprayer. Do not spray on windy days (over 11 MPH), and protective clothing must be worn with some products.Be sure to read the chemical label carefully.To determine the ground speed of your sprayer, measure and mark driving distances of 100, 200, or 300 feet. Our speed chart indicates the number of seconds needed to travel these distances. Set your throttle, and with a rolling start, drive the measured distance of your choice. Adjust your throttle until you can match the number of driving seconds needed. Mark the throttle setting and note the gear range so you can use them while spraying.Add water and chemicals in the proper amounts in the spray tank and drive to your starting point. When you are ready to spray, turn your boom control valve to the “ON”  position. Once the pump is turned on, the unit will begin spraying. The system pressure will decrease slightly when you see the solution flowing from the spray nozzles. This is normal, the pressure will return as before when you turn the control valve to the “OFF” position.You will find optimal spraying in the 20 to 30 PSI range.

AFTER SPRAYING

After use, all the sprayers partway with water. Start the sprayer and allow clear water to be pumped through the plumbing system and out through the spray nozzles.Refill the tank about half full with plain water and use a chemical neutralizer such as Nutra-Sol® or equivalent and repeat cleaning instructions. Flush the entire sprayer with the neutralizing agent.Follow the chemical manufacturer’s disposal instructions of all wash or rinsing water.Remove tips and screens from the boom. Wash tips thoroughly with water or cleaning solution (appropriate for chemicals used). Blow out orifice, clean and dry. If the orifice remains clogged clean it with a fine bristle (not wire) brush, or with a toothpick. Do not damage the orifice. Water rinse and dry tips before storing.

WINTER STORAGE

Drain all water and chemical out of the sprayer, paying special attention to the pump and valves. These items are especially prone to damage from chemicals and freezing weather.The sprayer should be winterized before storage by pumping a solution of RV antifreeze through the entire plumbing. Proper care and maintenance will prolong the life of the sprayer.

RATE CHART FOR 80/110-02 SPRAY TIP

Pressure(PSI) Capacity(GPM) GALLONS PER ACRE BASED ON WATER – 20″ SPACING
1 MPH88 FPM 2 MPH176 FPM 3 MPH264 FPM 4 MPH352 FPM 5 MPH440 FPM 7.5 MPH660 FPM 10 MPH880 FPM
20.0 0.14 41.8 20.9 14.0 10.5 8.4 5.6 4.2
30.0 0.17 51.2 25.6 17.2 12.9 10..3 6.9 5.1
40.0 0.20 59.2 29.6 19.8 14.9 11.9 8.8 5.9
50.0 0.23 66.4 33.2 22.2 16.6 13.3 8.8 6.6
Pressure(PSI) Capacity(GPM) GALLONS PER 1000 SQ. FT.BASED ON WATER – 20″ SPACING
20.0 0.14 .96 .48 .32 0.24 0.19 0.13 .10
30.0 0.17 1.18 .59 0.39 .30 0.24 0.16 0.12
40.0 0.20 1.36 .68 0.45 0.34 0.27 0.18 0.14
50.0 0.23 2. 1. 1. 0. 0. .20 0.
Pressure(PSI) Capacity(GPM) GALLONS PER 100 SQ. FT. BASED ON WATER – 20″ SPACING
20.0 0.14 0.96 0.78 0.32 0.24 0.019 0.012 0.09
30.0 0.17 0.117 0.059 0.39 0.29 0.024 0.015 0.011
40.0 0.20 0.135 0.066 0.045 0.034 0.027 0.018 0.013
50.0 0.23 0. 0.076 .050 0.038 0.030 .020 0.015

MPH- Miles Per Hour • FPM- Feet Per Minute • PSI- Pounds Per Square Inch • GPM- Gallons Per Minute

Assembly Instructions

1.0–Install ATV Boom Mounts & ATV Helix Levers in two places on the bottom of tank as illustrated using 5/16″ Flat Head Screws. Note the orientation of all parts as their orientation is essential for proper assembly.

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 2 600189 ATV Boom Mount
2 2 600190 ATV Helix Lever
3 4 600188 5/16-18 Flat Head Screws

PARTS LIST

ITEM QTY PART NUMBER DESCRIPTION
1 2 600191 Angle Bracket
2 1 640414 Center Section
3 2 640412 23″ End Section
4 2 640413 38″ End Section
5 4 640416 Center Bracket
6 2 640417 End Bracket
7 2 640428 Spring
8 6 640423 5/16 x 2″ Screw
9 6 640426 5/16 x 2.75″ Bolt
10 10 600172 5/16 Nut
11 6 620106 5/16 Lock Nut
12 2 640459 Spacer

Assembly Instructions

  1.  Insert Angle Brackets into Mounting Brackets and rotate lever to the locked position to secure in place
  2.  Install the Center Section onto the Angle Brackets at the desire high using 5/16 x 2.75″ bolts and 5/16 nuts.
  3.  Install (2) Center Brackets to each end of the Center Section using 5/16 x 2″ Screws and 5/16 nuts.Note the orientation of brackets as it is essential for proper assembly.
  4. Install End Brackets to End Sections (23″ for 5 Nozzle Boom, 38″ for 7 Nozzle Boom) using 5/16 x 2″ screws, 5/16 x 2.75″ bolts and 5/16 nuts. Note the orientation of brackets and the bolts as it is essential for proper assembly.
  5.  Install the End Sections to the Center Section using 5/16 x 2″ Bolts, 5/16 Lock Nuts and Spacer, as shown in the detailed view. Make sure to not over tighten the bolts, so that the boom ends can rotate freely.
  6. Install Boom Springs to 5/16 x 2.75″ bolts like shown in the detailed view.
  7.  Install 5/16 Lock Nuts onto 5/16 x 2.75″ Bolts to secure spring in position as shown in the detailed view.

Assembly Instructions

  1. Install Boom Clamps onto the Spray Boom Assembly using 1/4″ x 1.75″ bolts and 1/4″ Lock Nuts. Note: Boom Clamps should be space 20″ apart.
  2. Install Nozzle Body Fittings in BoomClamps and secure in place with N1116 P Nuts.
  3. Insert Check Valves into Nozzle Body Fittings.
  4. Insert Spray Tip into 8027 P Nuts and screw onto Nozzle Body fittings.
  5. Install Hose Assembly onto inline valve on the Pump Manifold.
PARTS LIST
ITEM 5 Nozzle QTY 7 Nozzle QTY PART NUMBER DESCRIPTION
1 5 7 640415 Boom Clamp
2 2 2 600112 NTL38 P Fitting
3 3 5 620112 NTT 38 P Fitting
4 5 7 600116 N1116 P Nut
5 5 7 600117 Check Valve / Strainer
6 5 7 640432 Flat Fan Spray Tip
7 5 7 600119 8027 P Nut
8 5 7 640427 1/4-20 x 1.75″ Bolt
9 5 7 600107 1/4-20 Lock Nut
10 1 1 600142 T38 P Fitting
11 12 16 600120 5/8″ Hose Clamp
12 1 0 640434 5 Nozzle Hose Assembly
13 0 1 640435 7 Nozzle Hose Assembly

PRECISION SPRAY EQUIPMENT®, a division of Green Leaf, Inc. 9490 N BALDWIN ST FONTANET, IN 47851 www.grnleafinc.com 800-654-9808

References

[xyz-ips snippet=”download-snippet”]


Posted