YRD256 CBA Assure Lock SL Connected
Yale® Assure Lock® SL Key Free Touchscreen Deadbolt Installation and Programming Instructions(YRD256)This manual will walk you through all the required steps to add your new Yale Assure Lock SL to your door.· Remove Existing Door Hardware· Double Check Door Measurements· Install your Assure Lock SL· Program your Assure Lock SL· Add your Assure Lock SL to your smart home system or August App*
Tools NeededStandard Phillips Head ScrewdriverTools necessary only for new doors or adjusting existing door
Before you beginDOWNLOAD THE BILT APPfor step-by-step installation instructions & to register your product
Tape
Pencil
Measure
Drill
Wood Mortise
Chisel
Utility Knife
Level
*If purchased with Yale Smart Module or Connected by August KitFAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT, VOIDING THE FACTORY WARRANTY AND COULD LEAD TO FAILURE OF THE PRODUCT TO PROVIDE ACCESS.1P/N YRD256-MNL-0003 Rev F
What’s In The Box
Optional Yale Smart ModuleKey Free Touchscreen KeypadLoosen screw to remove cover
Let’s Get StartedInstallation Guide Envelope (Includes this manual and door checker with template)
Battery Cover
4 AA Batteries
Inside Lock Assembly (Separates into 3 components)
Inside Lock
Mounting Plate
Mounting Hardware The mounting hardware box includes 16 components
Strike Plate
Adjustable Deadbolt
Inside Lock Strike Plate
Screws
and
Deadbolt Screws
Optional Security Strike Plate Screws
OR
OR
Screw Set B Green for 1-3/8″Door Thickness
Screw Set C BlackStandard for 1-3/4″Door Thickness
Screw Set D Silver for2 to 2-1/4″ Door Thickness
2P/N YRD256-MNL-0003 Rev F
1
Removing Existing Door HardwareDo not discard old lock hardware until Assure Lock SL has been successfully installed.
Frame3P/N YRD256-MNL-0003 Rev F
2 Check Door Measurements and Make Adjustments If Needed
Door CheckerUse door checker from installation guide envelope to verify your door measurements and make any needed adjustments.
Let’s Get Started
Check Your DoorGuide
New Door Marking TemplateWith door checker, use template from installation guide envelope to prep a new door that has not been predrilled for hardware.
Let’s Get Started
New Door Marking Template
4P/N YRD256-MNL-0003 Rev F
3 Installing Latch & Strike Plate*2-3/8″ Backset
x2Actual Sizex2Actual Sizex2Actual SizeChoose standard strike plate screws or security screws.
default
*2-3/4″ Backset
*Deadbolt latch position is based on backset. Choose position appropriate for your door. Reference Door Checker measurements E and F.
Bolt must be in retracted Press (unlocked)position.
Ooptional Pull
Bolt must be in retracted (unlocked) position. Note horizontal orientation of tailpiece slot and UPorientation of deadbolt latch.
Backset
5P/N YRD256-MNL-0003 Rev F
4 Installing Touchscreen Keypad
Inside of Door
Outside of Door
!Bolt must be in retracted (unlocked) position. Note horizontal orientation oftailpiece slot.6P/N YRD256-MNL-0003 Rev F
5 Installing Inside Mounting Plate
x2Actual SizeScrew Set D Silver for2 to 2-1/4″ Door Thickness
x2Actual SizeScrew Set C BlackStandard for 1-3/4″Door Thickness
x2Actual SizeScrew Set B Green for 1-3/8″Door Thickness
!Choose through bolt appropriate for your door thickness. Verify appropriatethrough bolt with the door checker.
Insert cable through cable hole.
Inside of Door
!Make sure keypad and mounting plate are straight before tightening screws.
7P/N YRD256-MNL-0003 Rev F
6 Attaching the Cable AssemblyInside of DoorEnsure cable is securely fastenedinto adapter.!Use cable hooks to ensure proper routing.Do not pinch wire.8P/N YRD256-MNL-0003 Rev F
7 Installing Inside Lock
x3Actual Size
Inside of Door
Horizontal
Ensure thumbturn is vertical. If the thumbturn does not move freely, referto the hardware troubleshooting steps.
9P/N YRD256-MNL-0003 Rev F
Testing Mechanical OperationInside of Door! If thumbturn operation fails, check the installation beginning with Step 3.10P/N YRD256-MNL-0003 Rev F
8 Installing Optional Yale Smart ModuleInside of Door!Batteries must not be installed prior to inserting and/or removing the YaleSmart module.For more information about Yale Smart modules and smart home features visit: https://www.yalehome.com/en/yale/yalehome/residential/yale-smart-home-guide/11P/N YRD256-MNL-0003 Rev F
9 Installing Batteries and Cover
Tighten screw to replace cover
“Welcome to Yale Real Living”
!Bolt must be in retracted (unlocked) position beforeinstalling batteries.
Inside of Door
Press the Yale logo to wake the lock. You will be guided to set up your lock by following the audio instructions on the lock.Additional entry codes and further programming can be done through the Settings Menu. Refer to page 15.
Congratulations, you’ve installed the Yale® Assure Lock® SL Key Free Touchscreen Deadbolt (YRD256)!12P/N YRD256-MNL-0003 Rev F
Using Your Lock
Touchscreen KeypadPress to wake keypad or lock doorPress to return to previous Settings Menu
Press to enter or unlockLow Battery Indicator
SpeakerEnter Master Entry Code and press to access Settings MenuAll Code Lockout Mode Indicator Battery Back-up Hold a 9V battery to the terminals in case of dead lock batteries
Inside Lock
Battery CoverInside Notification Light Privacy Button
Thumbturn formanual locking and unlocking
13P/N YRD256-MNL-0003 Rev F
1
Creating Master Entry CodeThe master entry code is used to change the lock settings. A security best practice is to set your master code with 6 or more digits and create a separate code that is used daily to lock and unlock the door.
“Register Master Code. Press the gearkey to continue.”
Enter 4-8 digit Master Entry Code
Press“Enter a 4 to 8 digit PIN code followed bythe gear key.”
“Registered”Press 14P/N YRD256-MNL-0003 Rev F
2
Creating Entry CodesMaster Entry Code must be created first. *Max user codes = 250 with Smart Module; 25 without.
Enter Master Entry CodePress
“Menu mode, press the gear key to continue.”
Press Press
Press Press
Enter 4-8 digit entry codePress (code flashes)
Adding more *User Codes:Press Enter 4-8 digit entry code Press
To end programming: Press
15P/N YRD256-MNL-0003 Rev F
3
Deleting Entry CodesEnter Master Entry Code Press
“Menu Mode, enter number, press the gear key to continue.”
Press Press
Press Press
Deleting one entry code: To delete one entry code, you must enter the entry code you wish to delete.Enter 4-8 digit entry code Press
To delete all entry codes (Does not delete Master Entry Code):Enter Press
16P/N YRD256-MNL-0003 Rev F
4 Unlocking Door with Entry CodesEnter Entry Code Press17P/N YRD256-MNL-0003 Rev F
Setting Definitions
Settings Master Entry CodeAuto Re-lockInside Indicator Light One Touch LockingPrivacy Button Volume LanguageAll Code Lockout Mode Wrong Code Entry LimitShutdown Time
Default Setting
Definition
Creation required*
The Master Entry Code is used for programming and for feature settings. It must be created prior to programming the lock. The Master code will also operate (unlock/lock) the lock.
Disabled
After a successful code entry or manual unlock with the key, the lock will automatically re-lock after each unlock in an effort to keep your home secure. This feature is optional, and can be turned off. In the ON mode, the lock will automatically re-lock after thirty (30) seconds.
Disabled (Off) Enabled
Located on the inside lock. Shows active status (Locked) of lock and can be enabled or disabled in the Advanced Lock Settings (Main Menu selection #3).When the latch is retracted, activating the keypad will extend the latch (during Auto Re-lock duration or when Auto Re-lock is disabled). When One-Touch Re-lock is not in use (disabled), any valid PIN code will re-lock the lock.
Disabled
Privacy mode is disabled by default. Enable Privacy mode by pressing the privacy button for 4 seconds to put the lock in donot-disturb mode (all pin codes are disabled).
Enabled (Low)
The volume setting for entry code verification is set to Low (2) by default; otherwise it can be set to High (1) or Silent (3) for quiet areas.
English
Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the lock’s voice prompts.
Disabled 5 Times 60 Seconds
This feature is enabled by the Master Entry Code. When enabled, it restricts all user (except Master) Entry Code access. When attempting to enter a code while the lock is in All Code Lockout mode, the RED locked padlock will appear on the screen.After five (5) unsuccessful attempts at entering a valid entry code, the lock will shut down and not allow operation for sixty (60) seconds.The Lock will shutdown (flashing RED) for sixty (60) seconds and not allow operation after the wrong code entry limit (5 attempts) has been met.
*The Master Entry Code must be created prior to any other programming of the lock.
18P/N YRD256-MNL-0003 Rev F
Customizing Lock Through Settings Menu*Master Entry Code Required
1. Press Yale logo to wake up lock . 2. Enter Master Entry Code* followed by icon.Lock Response: “Welcome to the Settings Menu. Press each number to hear available settings and then press the settings icon to enter.” 3. Enter digit corresponding to the function to be performed followed by the icon. Follow the voice commands.
Advanced Lock Settings
Auto Re-lock Inside Indicator Light
Disable 30 sec 60 sec 2 min 3 minEnable Disable
Remain in Settings MenuOR Exit Settings Menu
One Touch Locking
Enable Disable
Privacy Button Setting
Enable Disable
Volume Setting Language Setting Mode All Code Lockout Mode **Network Module Setting
Handing the Lock
High
Low
OR
Silent
English
Spanish
OR
French
EnableOR Disable
Join the Network Exit the Network
Preforms automatic OR handing of the lockDefault settings in bold.OR
Here is an example of how to set Auto Lock to 30 seconds: Master Entry Code , 3 , 1 , 2 ,*The Master Entry Code must be created prior to any other programming of the lock. **Network Module Setting function appears only with Yale Smart module installed.19P/N YRD256-MNL-0003 Rev F
Troubleshooting
SymptomLock does not respond door is open and accessible.Lock does not respond door is locked and inaccessible.
Suggested Action· Yale keypad becomes active when the Yale logo is pressed. Verify contact with the logo.· If keypad numbers are visible, check to see if they respond when pressed. · Check batteries are installed and oriented correctly (polarity) in battery case. · Check batteries are in good condition; replace batteries* if batteries are dead. · Check to see if keypad cable is fully connected and is not pinched.· Batteries may not have enough power. Replace batteries*. · Apply a 9V battery to terminals below the keypad for backup power option.
Lock is on for a while then shows no reaction. Lights dim.
· Batteries do not have enough power. Replace batteries*.
Lock chimes to indicate code
· Check the door gaps for any foreign objects between door and frame.
acceptance, but door will not open. · Check that the cable is firmly connected to the inside lock.
Lock operates to allow access, but will not automatically re-lock. Entry codes will not register.
· Check to see if Auto Re-lock is enabled. · Disable Auto Re-lock to lock the door (manually). · If low battery indicator is lit, change batteries*.· Entry codes must consist of 4 to 8 digits. · The same entry code cannot be used for multiple users. · Management of entry codes is set by the authority of the Master Code, which isset first. Contact the Master user.· Entry codes must be entered within 5 seconds (while keypad is active) or process will have to be restarted.· Check or gear cannot be used as part of the entry code.
Upon entering an entry code and pressing key, the lock displays “invalid code” error or lock times out without responding.
· Verify entered code is a valid, previously programmed, 4 to 8 digit code. · All Code Lockout Mode is enabled. Only the Master Entry Code canenable/disable All Code Lockout Mode. Contact the Master user.
Upon entering an entry code and
· Check to see if the lock is set to All Code Lockout Mode. Setting/managing All
pressing the key, red padlock icon Code Lockout Mode is done through Master Entry Code only.
appears and there are different tones. Contact Master user.
Lock operates, but makes no sound. · Check to see if Volume is set to Silent (see Feature #4).
Lock responds “Low Battery” Upon entering an entry code and pressing the key, lock responds “Wrong number of digits”. Lock shows an X on keypad after entering a code.Deadbolt does not extend when locking the door with keypad.
· This is the alert to replace the batteries. Replace all four (4) batteries* with new AA Alkaline batteries.· The digits entered were incorrect or incomplete. Re-enter the correct code followed by the check key.· Bolt failed to fully retract. Refer to the “Hardware Troubleshooting” steps on page 21.· Entry code has not been scheduled for use at time of day it is tried. Try entry code again during its scheduled time.· Lock was not handed properly. Rehand lock through settings menu.
* When batteries are replaced, Smart Module locks have a real time clock that will be set through the User Interface (UI); it is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).
20P/N YRD256-MNL-0003 Rev F
Hardware TroubleshootingThumbturn Door Open
Keypad Door Open
If deadbolt does not extend or retract easily when testing thumbturn and keypad operation, revisit inside and keypad installation steps. It is important that the bolt be in the retracted position during lock installations and that installation procedure is followed carefully.Helpful Tip: Ensuring smooth deadbolt operation can enhance your battery life.Thumbturn Door ClosedTest with door closed using thumbturn.
If you feel resistance, ensure deadbolt strike plate aligns with deadbolt. If deadbolt strike plate is out of alignment, please attempt to adjust knob/lever/handleset strike using steps below. The knob/lever/handleset latch engagement into the strike is the main component used for door alignment.If deadbolt does not fully extend, consider increasing depth of deadbolt strike pocket in frame.To adjust Knob/Lever/Handleset strike plate:1. Remove plate from door frame with a manual screwdriver. (Using an electric driver may strip screw heads or enlarge screw holes.)
Tab2. Locate strike plate tab. Bend the tab towards surface of strike. Note: a small change may be all that is required3. Reinstall strike plate using a manual screw driver and test again.4. If door cannot be adjusted sufficiently with strike tab, both knob/lever/handleset latch and deadbolt latch could require adjustment we suggest you contact a local locksmith for assistance.For help with misalignments, watch our door alignment video: https://www.yalehome.com/en/yale/yalehome/support/ yrl-electronic-lock-faqs/electronic-lock-installation/
21
P/N YRD256-MNL-0003 Rev F
Resetting Lock to Factory Default
When lock is reset to factory defaults all user codes (including the Master Entry code*) are deleted and all programming features are reset to original default settings (see below).
Reset Button
1. Remove the battery cover and batteries. 2. Remove the interior side of the lock to access thereset button. 3. The reset button (see image at right) is located besidethe cable adapter. 4. While pressing the reset button (minimum of 3 seconds)reinstall batteries. Release reset button. 5. Replace battery cover.
Upon reset, Master Entry Code creation is the only option available and must be performed prior to any other programming of the lock.
Interior Lock
NOTE TO INSTALLER AND CONSUMER While Yale® has included several features to prevent lockout(9-Volt battery jumper, low battery warnings), it is still possiblefor a lockout situation to occur. Because this product does not have a mechanical override (a key), Yale® recommends to usethis product in an environment where there are additionalentry points into the dwelling.
FCC: Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Y Reorient or relocate the receiving antenna. Y Increase the separation between the equipment and receiver. Y Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Y Consult the dealer or an experienced radio/TV technician for help.Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY Residential Group could void the user’s authority to operate the equipment.Industry Canada: This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Cet appareillage numérique de la classe A répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement.
Product Support Tel 1-855-213-5841 · www.yalehome.comYale® and Assure Lock® are registered trademarks of ASSA ABLOY Residential Group. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. © Copyright 2018-2020. All rights reserved. Reproduction in whole or in part without the express written permission ofASSA ABLOY Residential Group is prohibited.
22P/N YRD256-MNL-0003 Rev F
®
Yale® Z-Wave® Plus Smart Module
Installation Guide
Please use this procedure only when network primary controller is missing or otherwise inoperable.Adding a Yale Z-Wave® Plus Smart Module to your Assure Lock & Z-Wave System1. Install the Yale Smart Module into the slot above the battery compartment IMPORTANT: The batteries must be removed before removing the Yale Smart Module: · Remove battery cover · Remove batteries · Insert or remove Yale Smart Module · Reinstall batteries · Reinstall battery cover2. Open the Z-Wave system’s smart home or alarm app on your smartphone or tablet3. Follow the in-app instructions for adding a new device4. On your lock keypad, enter your master entry code followed by the icon5. Press the 7 key followed by the icon6. Press the 1 key followed by the iconRemoving a Yale Z-Wave® Plus Smart Module from your Assure Lock & Z-Wave System1. On your lock keypad, enter your master entry code followed by the icon2. Press the 7 key followed by the icon3. Press the 3 key followed by the icon4. Open the Z-Wave system’s smart home or alarm app and follow the instructions for removing a device5. Remove the Yale Smart Module from the slot above the battery compartment IMPORTANT: The batteries must be removed before removing the Yale Smart Module: · Remove battery cover · Remove batteries · Insert or remove Yale Smart Module · Reinstall batteries · Reinstall battery cover6. If you’re adding a new Yale Smart Module, follow the instructions included with itP/N AYR202-ZW-INSTAL-FUL Rev E
Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY! Residential Group could void the user’s authority to operate the equipment.This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions. This product can be operated in any ZWave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
FCC: Contain FCC ID: U4A-YRHCPZW0FM Model: YRMZW2-US This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Y Reorient or relocate the receiving antenna. Y Increase the separation between the equipment andreceiver. Y Connect the equipment into an outlet on a circuitdifferent from that to which the receiver is connected. Y Consult the dealer or an experienced radio/TV technicianfor help.
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. En vertu des règlements d’Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne d’un type et un maximum (ou moins) approuvés pour gagner de l’émetteur par Industrie Canada. Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie.Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.Industry Canada: Contain IC: 6982A-YRHCPZW0FM Model: YRMZW2-US Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain
This radio transmitter 6982A-YRHCPZW0FM has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.Le présent émetteur radio 6982A-YRHCPZW0FM a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal. Les types d’antenne non inclus dans cette liste, et dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.CAN ICES-3B/NMB-3B
24/7 Tech Support : 1-855-492-0505 · www.yalehome.comYale® is a registered trademark of ASSA ABLOY Residential Group. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. © Copyright 2019. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Residential Group is prohibited.
Yale® ZigBee® Module®Installation and Programming InstructionsInstalling the ZigBee® ModuleIMPORTANT: the batteries must be removed prior to removing and/or inserting the network module:· Remove battery cover. · Remove batteries. · Remove and/or insert network module. · Reinstall batteries. · Replace cover.Enrolling/Unenrolling the Network Module:This device is a security enabled ZigBee product that is able to use encrypted ZigBee messages to communicate to other security enabled ZigBee products. This device must be used in conjunction with a Security Enabled ZigBee Controller in order to fully utilize all implemented functions. This product can be operated in any ZigBee network with other ZigBee certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. To Enroll the Module (Inclusion Mode):· Enter the 4-8 digit Master PIN code followed by the key. · Press the key followed by the key. · Press the key followed by the key. To Unenroll the Module (Exclusion Mode): · Enter the 4-8 digit Master PIN code followed by the key. · Press the key followed by the key. · Press the key followed by the key.P/N AYR202-ZB-INSTAL-FUL Rev C
FCC: FCC ID: U4A-YRHCPZB0FM Model: YRMZB2 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment andreceiver. Connect the equipment into an outlet on a circuitdifferent from that to which the receiver is connected. Consult the dealer or an experienced radio/TVtechnician for help.This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by manufacturer could void the user’s authority to operate the equipment.IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Industry Canada: IC: 6982A-YRHCPZB0FM Model: YRMZB2 This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement.Important Note: Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Note Importante: (Pour l’utilisation de dispositifs mobiles) Declaration d’exposition aus radiations: Cet équipement est conforme aux limites d´exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipment doit être installé et utilisé avec un mimimum de 20 cm de distance entre la source de rayonnement et votre corps.IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. IMPORTANT! Tous les changements ou modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l’utilisateur pour actioner cet équipment.CAN ICES-3B/NMB-3B
Product Support Tel 1-855-213-5841 · www.yalehome.comYale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.Yale® and Yale Real Living® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only.Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.YALE, with its unique global reach and range of products, is the world’s favorite lock the preferred solution for securing your home, family and personal belongings. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
Yale® iM1 Network Module®Installation and Programming InstructionsInstalling the Yale iM1 Network ModuleIMPORTANT: the batteries must be removed prior to removing and/or inserting the network module:· Remove battery cover and batteries. · Remove and/or insert Network Module. · Reinstall batteries and battery cover.Enrolling the iM1 Network Module:The Yale iM1 Network Module must be used with a Yale Assure Lock or Yale nexTouch Lock and cannot be used in conjunction with any other Yale Network Module.To Enroll the Module: ·Enter the 4-8 digit Master PIN code followed by the key. ·Press the key followed by the key. ·Press the key followed by the key.Connecting the Yale Secure App with the Yale iM1 Network Module1. After following steps listed on other side of page for enrolling module, download the Yale Secure app from App Store®.2. Ensure Bluetooth® is enabled on your iPhone®, iPad® or iPod touch®, and that you’re within a foot of your Yale lock.3. Open the Yale Secure app and agree to allow app to access your Home Data.4. If you do not have a home already created, create a new home when prompted. Tap + to add a new Yale Lock.5. The App will search for your Yale Lock. Be sure that you are within close proximity (less than two feet or so). When “Yale Lock” appears, tap to add. *If lock does not appear, enter your Master Pin Code on lock keypad, tap gear, tap 7, tap gear, tap 1 and then tap gear.6. Scan your Accessory Setup Code; shown below, or manually enter within the app.Accessory Setup CodeP/N AYR202-iM1-INSTAL-FUL Rev E
FCC: Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Y Reorient or relocate the receiving antenna. Y Increase the separation between the equipment and receiver. Y Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected. Y Consult the dealer or an experienced radio/TV technician for help. THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Industry Canada: Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. En vertu des règlements d’Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne d’un type et un maximum (ou moins) approuvés pour gagner de l’émetteur par Industrie Canada. Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie.Section 7.1.3 of RSS-GEN This Device complies with Industry Canada Licenseexempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.CAN ICES-3B/NMB-3B
Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY Residential Group could void the user’s authority to operate the equipment.
Product Support Tel 1-855-213-5841 · www.yalehome.comYale®, Yale Real Living® and Assure Lock® are registered trademarks of ASSA ABLOY Residential Group. nexTouchTM is a trademark of ASSA ABLOY Residential Group. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. Copyright © 2019, ASSA ABLOY Residential Group. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Residential Group is prohibited.Apple®, iPhone®, iPad®, iPod touch® and Siri® are trademarks of Apple Inc., registered in the U.S. and other countries. HomeKit is a trademark of Apple Inc. Use of the Works with Apple HomeKit logo means that an electronic accessory has been designed to connect specifically to iPod touch, iPhone or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliancewith safety and regulatory standards. Use of the HomeKit logo means that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
References
[xyz-ips snippet=”download-snippet”]