D-Link AC1200 Wave 2 Dual-Band PoE Access Point DAP-2662 Installation Guide

D-Link AC1200 Wave 2 Dual-Band PoE Access Point 
DAP-2662  Installation Guide

Documentation also availablevia the D-Link Website

Before You Begin

This installation guide provides instructions for installing the DAP-2662 on your network. Additional documentation is also available onthe D-Link support website.

  • D-Link Nuclias Connect User Manual: For additional information and instructions on how to configure the device using D-Link Nuclias Connect.
  • DAP-2662 User Manual: For additional information and instructions on how to configure the device using the web user interface.

Package Contents

This DAP-2662 package should include the following items:

  • 1 x DAP-2662
  • 1 x Quick Install Card
  • 1 x Mounting bracket
  • 2 x Ceiling brackets
  • 4 x Rubber stands
  • 4 x Screws
  • (Optional) 1 x Power supply

If any of the above items are damaged or missing, please contact your local D-Link reseller.

System Requirements

  • A PC or laptop with a working Ethernet adapter or wireless interface.
  • Mozilla Firefox 52.0 or higher, Internet Explorer 11 or higher, Safari 10.1 or higher, Google Chrome 59 or higher.
  • OS X 10.8.5, Windows 7, Linux (Ubuntu 12) and higher.

Hardware Overview

LED Indicators

Figure 1: Front Panel LED

Table 1: LED Description

Interface Connectors

Figure 2: Bottom Connectors

Table 2: Interface Description

Powering the Access Point

Using Power over Ethernet (PoE)

Use a standard Ethernet cable to connect the LAN port on the DAP-2662 to a PoE power source device such as a PoE switch or PoE injector.

(Optional) Using the power adapter

1. Connect the power connector of the adapter to the power input on the DAP-2662 and plug the adapter into a nearby power outlet.

Configuring the Access Point

Note: D-Link recommends configuring the device before mounting it.

Using D-Link Nuclias Connect

The DAP-2662 is designed to be managed through D-Link Nuclias Connect. Refer to the D-Link Nuclias Connect Manual for detailed configuration instructions.

Figure 4: Connecting through D-Link Nuclias

1. Download the free Nuclias Connect app from the App Store or Google Play by searching for Nuclias Connect or by scanning the QR code below.

2. Open the Nuclias Connect app and follow the onscreen instructions to discover and set up your device.

Manual Configuration

If you are not using Nuclias Connect, you may manually configure the DAP-2662 using its web user interface (UI). Refer to the DAP-2662 User Manual for detailed configuration instructions.

Use the following methods to access the web user interface:

Note: The management computer must be in the same subnet as the DAP-2662.

  1. Use an Ethernet cable to connect the management computer to the PoE switch or to the PoE Injector the DAP-2662 is connected to.
  2. Open a web browser on the management computer and type in dap.2662.local in the address field and press Enter.
  3. When prompted, enter the default login credentials:User name: adminPassword: admin

Mounting the Access Point

The DAP-2662 can be mounted on a wall or ceiling for optimal coverage.

Mounting on a Solid Wall or Ceiling

1. Use the mounting plate to mark the location where to drill the holes in the wall or ceiling.

Figure 5: Mark Location

2. Drill holes on the markings and place the included anchors into the drilled holes.

Figure 6: Drill Holes

3. Align and place the mounting plate on top of the anchors and use the included screws to secure the mounting plate to the surface.

Figure 7: Attaching the Mounting Plate

4. Connect the Ethernet cable and power adapter (optional) to the device.5. Attach the DAP-2662 to the mounting plate by snapping the device into place onto the plate and rotating clockwise until the device locks into place.6. Use the Allen key and screw to lock it in at the top.

Mounting on a Ceiling Crossbar

1. Clip the two included ceiling brackets onto a ceiling crossbar. Make sure both brackets are positioned in line with each other.

Figure 8: Attaching the Ceiling Brackets

2. Use the included screws to secure the mounting plate to the ceiling brackets.

Figure 9: Attaching the Mounting Plate

3. Connect the Ethernet cable and power adapter (optional) to the device.4. Attach the DAP-2662 to the mounting plate by placing it onto the plate and rotating clockwise until the device locks into place.

Reboot/Reset the Access Point

If necessary, the DAP-2662 can be manually rebooted or reset to factory default settings.

Rebooting the device

Unplug the Ethernet cable (if connected to PoE power source device) or the power adaptor to power off the device and replug it to power it on again.

Resetting the device

Press and hold down the recessed reset button at the bottom of the device for 6 to 15 seconds then release to reset the device to its factory default settings.

Additional Information

For additional support, please refer to the user manual, or visit your local D-Link support website.

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

– Reorient or relocate the receiving antenna.– Increase the separation between the equipment and receiver.– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.– Consult the dealer or an experienced radio/TV technician for help.

Non-modifications Statement:

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Caution:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible.

Note

The country code selection is for non-USA models only and is not available to all USA models. Per FCC regulations, all WiFi product marketed in the USA must be fixed to USA operational channels only.

RF Frequency Requirements

This device is for indoor use only when using all channels in the 5.15 to 5.25 GHz frequency range. High power radars are allocated as primary users of the 5.25 to 5.35 GHz and 5.65 to 5.85 GHz bands. These radar stations can cause interference with and/or damage this device. This device will not operate on channels which overlap the 5600-5650 MHz band.It is restricted to indoor environments only.

IMPORTANT NOTICE:

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.

Innovation, Science and Economic Development Canada (ISED) Statement:

This Class B digital apparatus complies with Canadian ICES-003.

Innovation, Science and Economic Development Canada (ISED) Statement:

This device complies with ISED licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;

Operations in the 5.25-5.35 GHz band are restricted to indoor usage only.

Radiation Exposure Statement

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.

Japan Voluntary Control Council for Interference Statement

This is a Class B product based on the standard of the VCCI Council. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.

Product and Warranty Information

To find out more about D-Link products or marketing information, please visit the website http://www.dlink.com.

The D-Link Limited Lifetime Warranty information is available at http://warranty.dlink.com/

 

 

report this ad

Ver. 1.01(WW)_130x1832019/10/045300-7597-01W

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by