HARMAN CBT 1000 Professional Loudspeakers User Guide

HARMAN CBT 1000 Professional Loudspeakers User Guide

Wiring Guide for 1x CBT 1000 speaker

Connect 1 amplifier channel to each CBT 1000 speaker

Recommended Amplifiers

  • Crown XTi6002 – 2100W @ 4 ohmsOR(One channel for each CBT 1000)
  • Crown CDi6000 – 2100W @(One channel for each CBT 1000)OR
  • Crown DCi2x2400N – 2400W @ 4 ohms(One channel for each CBT 1000)

Amplifier Selection Considerations

  • How much power is needed (less powerful amplifiers can be used if you don’t need all the SPL the speaker is capable of producing. However, pushing a lowerpower amplifier into clipping can damage the speaker).
  • How much DSP and which DSP functions are required.
  • Whether the amp needs to be networked (DCi-N).
  • Project’s budget.

Wiring Guide for 1x CBT 1000 speaker + 1x CBT 1000E Array

Connect 1 amplifier channel to each CBT 1000 + CBT 1000E array

Recommended AmplifierCrown DCi2x2400N – 2400W @ 4 ohms(One channel for each CBT 1000)

Note:

  • Important – The CBT 1000E must be connected in parallel with the CBT 1000 and the two of them MUST be in proper polarity. “+” to “+” and “–” to “–”.
  • Other system configurations are available. Please reach out to your Harman sales rep for details. And exception request may be required, depending on equipment utilized.

Selectable Coverage Patterns

  • Upper-Half Coverage Pattern Selections

Coverage Pattern Selection Panel — Located on side of cabinet; covered by plate. Remove screws using #1 Phillips-head screwdriver (not included).Position the orange headers to select the Upper and Lower coverage patterns and Music/Speech voicing.

(Header position example shown above: Upper Half NARROW pattern setting; Lower Half DOWNFILL pattern setting; EQ is MUSIC/FLAT setting.)

DSP Processor Settings for 1x CBT 1000 or for 1x CBT 1000 + 1x CBT1000E ArrayHigh-Pass & Limiter Settings:

  • Protective High-Pass: 35 Hz, 24 dB/oct, Linkwitz-Riley
  • LevelMax™ Limiter Settings:
    • RMS Thresdhold (VRMS): 65VClick the “Automatic” Radial Button to set Peak threshold, Peak Release, and RMS Release to “Auto”
  • Transducer Thermal Limiting, Thermal Voltage: 52V
  • Thermal Response Time (Sec): 10 Sec

For recommended on- and off-wall EQ settings, go to:https://jblpro.com/en-US/site_elements/cbt-1000-1000-e-eq-tunings

For more information about the CBT 1000 and CBT 1000E, go to:https://jblpro.com/en-US/products/cbt-1000 and https://jblpro.com/en-US/products/cbt1000-plus-cbt-1000e-system

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by