VOXX PRESTIGE APS787Z Security and Remote Start User Guide

VOXX PRESTIGE APS787Z Security and Remote Start

For Complete Installation Guide and Technical Support Please Visit www.voxxuniversity.comOr Call 1-800-225-6074

Notifications

AlarmWhen the alarm is triggered the system will provide feedback to the user. Upon disarm, the system will beep four (4) times and flash the LED to indicate the Alarm Trigger Zone.

1 Shock
2 Trunk / Hood
3 Door

Remote StartIf the remote start fails to start the vehicle, the system will flash the vehicle parking lights to indicate the cause.

1 Run�me Expired
2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach

Chirp DeleteSystem ARM/DISARM chirps can be toggled ON or OFF without entering the Feature Bank programming.

  1. Turn the ignition key ON/OFF.
  2. Press and release the valet button three (3) times.The system will respond with one (1) chirp for ON and two (2) chirps for OFF. This feature will not affect alarm trigger or feature programming.

User Programmable LEDSystem LED notifications can be turned ON or OFF without entering Feature Bank programming.

  1. Turn the ignition key ON/OFF, ON/OFF.
  2. Press and hold valet button for five (5) seconds.The LED will flash one (1) time for ON, two (2) times for OFF. This feature will not affect LED flash during feature programming.

Remote Programming

The APS787Z Includes two (2) preprogrammed remotes. When adding additional remotes, the remotes must be programmed to the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto Programming:

  1. Turn the ignition key to ON.
  2. Press and release the valet button three (3) times. System will beep and flash the parking lights one (1) time.

Press the lock button on each remote. The system will beep one (1) time to indicate the remote has been programmed. Only primary remote functions are auto programmed. This Includes Lock, Unlock, and Trunk/Start.If using AUX output control, you must manually program the AUX output channels to the remote. Please see the complete installation guide for manual remote programming instruction.

Note: If programming 2-Way remotes, wait for the remote to beep before programming additional remotes. This beep is confirmation that a 2-Way response has been received from the main module.

Feature Programming

The APS787Z Feature Banks can be programmed by using the valet button and remote. To enter Feature Bank programming:

  1. Turn the ignition key to ON.
  2. Press and release the valet button three (3) times. The system will beep and flash lights one (1) time for Feature Bank 1, Remote Programming.
  3. Cycle ignition key OFF/ON. The system will beep and flash the lights two (2) times for Feature Bank 2.
  4. Press valet button to cycle features. The LED will flash to display feature number.
  5. Press lock button to cycle options. The system will beep to indicate option number.
  6. Cycle ignition key OFF/ON. The system will beep and flash the lights three (3) times for Feature Bank 3.
  7. Press valet button to cycle features. The LED will flash to display feature number.
  8. Press lock to cycle options. The system will beep to indicate option number.

Tach Programming

The installer must manually configure the Engine Confirmation method in Feature Bank 3, Feature 5. The default method is “Tach”. When using the default “Tach” method, the vehicle tach rate must be programmed. To enter tach rate programming:

  1. Turn the ignition key ON.
  2. Press and release the valet button three (3) times.
  3. Turn the ignition key OFF.
  4. Press and hold valet button.
  5. While holding valet button, start the engine using the key.
  6. Hold the valet button for approximately ten (10) seconds. If connected to the vehicle Tach source, the system will flash the parking lights one (1) time every second.
  7. Release the valet button. The system will turn on the parking lights for two (2) seconds to indicate the tach rate is programmed.

The tach rate can also be programmed without the use of a valet button. This is helpful when using the OEM remote or CarLink system to control this module. To program the tach rate without a valet button:

  1. Turn the ignition key to the ON position and start the vehicle’s engine.
  2. Wait for engine RPM to lower to a normal idle.
  3. Press and hold the vehicle’s brake pedal.
  4. Press the LOCK button on the OEM remote or the Carlink App.

Note: Programming tach signal via OEM or Telematics control is only available on Firmware v1.47 or Higher.

Data Protocol Selection

The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable of detecting the correct data port protocol (ADS or DBI) and automatically configuring Feature Bank 2; Feature 18. To initialize the detection procedure:

  1. Press and hold the valet button.
  2. Cycle the vehicle’s Ignition ON/OFF two (2) times.
  3. Release the valet button.The system will automatically detect and set the correct data port protocol, ADS or DBI.

Note: This feature is only available on module firmware v2.0 or higher.

The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.

Feature Bank 2 Options
1 Chirp 2 Chirp 3 Chirp 4 Chirp 5 Chirp 6 Chirp
Features 1 Lock / Unlock Function 500ms 3.5sec 500ms L, DBL UL DBL L, 500ms UL DBL L, DBL UL 500ms L, 350ms UL
2 Ignition Lock OFF ON        
3 Ignition Unlock OFF Unlock All Unlock Driver      
4 Exterior Illumination OFF With Arm With Disarm With Arm & Disarm    
5 Auto Relock OFF Auto Lock Only Auto Lock & Arm      
6 Auto Arming / Locking OFF Auto Arm Only Auto Lock & Arm      
7 Notification Sound Both Siren Horn      
8 Horn Timing 16ms 30ms 40ms 50ms 10ms  
9 Valet Override Method Valet Custom Code Stand Alone Valet      
10 Driver Priority Unlock OFF ON        
11 Silent Choice OFF From Transmitter OEM Style      
12 Security Profile All On Doors off Hood / trunk Off All Off All On w/ OEM RS  
13 Door Trigger Input Negative Positive        
14 Park Light / Trunk Swap OFF ON        
15 Data Port Protocol ADS DBI        
16 Dome Light Delay Timer OFF / Program 15sec 30sec 45sec 60sec 120sec
17 Alarm Trigger Length 30sec 45sec 60sec 90sec 120sec  
Feature Bank 3 Options
1 Chirp 2 Chirp 3 Chirp 4 chirp 5 Chirp 6 Chirp
Features 1 Defrost Output Pulsed 10min RS Runtime      
2 RS Start Notification ON OFF        
3 RS Runtime 15min 20min 45min 60min 5min 10min
4 RS Parking Lights Steady Flashing        
5 Engine Confirmation Tach Voltage Data Hybrid    
6 Voltage Level >0.5v B4 Start <0.5v B4 Start        
7 Ignition 2 Output Ignition Accessory Start      
8 Ignition 3 Output Ignition Accessory Start      
9 Accessory Output Accessory Ignition Start      
10 Transmission Auto Manual        
11 Max Crank Time 0.8sec 1.0sec 1.5sec 2.0sec 3.0sec 4.0sec
12 Diesel Delay OFF Diesel 5 Diesel 10 Diesel 15 Diesel 20 Diesel 30
13 Temperature Start OFF 14F 5F 0F -4F -14F
14 Crank Duration Averaging Preset        
15 RS Shock Override Shunt until Clear Shunt RS Cycle Shunt From TX      
16 Turbo Timer OFF 3min 5min 10min    
17 Start Activation Two Press One Press Three Press      
18 RS Lock Function No Change UL Before L After UL Before Start Lock After Start    
19 Factory Disarm Output Single Pulse Double Pulse 350ms 500ms 800ms Same As Bank 2, F1
20 Additional Unlock Pulse No Pulse IGN, ACC, GWR IGN,ACC,GWR,PASD      

Dome Delay Programming

This system can be programmed to ignore the vehicle’s theater dimming dome light. This feature will be used when connecting the door trigger input to the dome light circuit for alarm trigger.Start with all doors closed and the vehicle dome light off.

  1. Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
  2. Open and close the driver door.

The system will monitor the dome light circuit. When the dome light turns off the system will set the delay time and add an additional two (2) seconds.

Dome Delay Reset

  1. Key ON/OFF, ON/OFF, ON/OFF.
  2. Press and hold valet button for five (5) seconds.

The system will beep one (1) time to indicate reset is complete.

Programmable Input Control

Programmable Input Control allows any PIC be configured to one of the options listed below. This feature is accessible via FlashLogic Weblink or Weblink Mobile only.

Door Trigger Full Shock Trigger
Trunk Trigger Parking Brake
Hood Trigger Brake
N.C. Door Trigger External Start Activation
Pre-Warn Shock Trigger Diesel Glow Plug

Negative Output Control (NOC)Negative output control allows any NOC to be programmed for any one of the options below. This feature is accessible via FlashLogic Weblink or Weblink Mobile only.

Lock Ground While Armed
Unlock Ground While Disarmed
2nd Unlock Domelight
Trunk Headlight
Remote Start Status Defrost
Ignition LED
Accessory Ch. 4 AUX
Pulse During Crank Ch. 5 AUX
Pulse After Shutdown Ch. 6 AUX
Factory Arm Ch. 7 AUX
Factory Disarm  

AUX Output ControlAny AUX output can be configured using the AUX Control Menu. This feature is accessible via FlashLogic Weblink or Weblink Mobile only.

1 Second Pulse 30 Second Pulse
5 Second Pulse Push & Hold
10 Second Pulse Latch ON/OFF
15 Second Pulse Latch 10min w/ RS
20 Second Pulse Latch Runtime