– Click [Add] icon in Z-Wave PC Controller Program.– Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.– If Inclusion Process is successful, Green led will turn off.
2-Device Exclusion
– Click [Remove] icon in Z-Wave PC Controller Program– Press the Net_Button 3 times within 1.5s– If Exclusion Process is successful, Green led is Blinking 6 times, then turn off.
3-Device test mode
if Inclusion process is successful, Press Test_Button to test if the device is working normally.
Red LED blinks 3 times when smoke is detected.
4-Device detection mode
if Inclusion process is successful, the device will report alarm information if detect the status change of smoke and no smoke . Red LED blinks quickly when smoke is detected.
5-Device Factory Reset
– Long press Net_Button while installing batteries in HS1SA-Z.– Device Reset Locally notification is Transmitted.– Please use this procedure only when the network primary controller is missing or otherwise inoperable.
6-Association & Association Group Information
– Lifeline between controller and HS1SA-Z– Supported command classes
– Maximum supported nodes are 5.– Association Group description
Association group 1: Lifeline association group
Include command classes: Battery report, Notification report, and Device Reset Locally notification, Binary report.
Association group 2: Root Device group(Binary Sensor)Binary Sensor Command Class: Compatible with 300 series
1- Binary Sensor reports status of smoke or no smoke via Lifeline.2-When the sensor detects status change between smoke and no smoke, the device will be triggered.
Association group 3: Root Device group(Notification)
1- Notification reports reports status of detect smoke or no smoke via Lifeline.2- When the sensor detects status change between smoke and no smoke, the device will be triggered.
7-Notification Report
-Press or release test button, or smoke status is changed(smoke detected or no smoke detected) , Notification Report is transmitted
Notification Type
Event
Smoke Alarm (0x01)
Previous Events cleared ( 0x00)
Smoke detected, Unknown Location(0x02)
8-Battery Report
– Battery Report is transmitted when power on the device.– Battery Report is transmitted once a day.– Battery Report is transmitted when the battery falls less than 10%
– Wake up Notification is transmitted every 24 hours by default.– Wake up Notification is transmitted after Notification Report is Transmitted
10-Devices from multiple manufacturers in one network
– This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applicants. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
11-Z-Wave Specifications
Device Type : Sensor – Notification
Role Type : RSS (Reporting Sleeping Slave)
Command Class Support/Control Z-Wave plus info Version Manufacture Specific Notification Device Reset Locally Association Group Information• Association Battery Wake Up Power Level• Binary Sensor
12-Indicate LED statues description-
Status
LED status
Alarm sound
Normal
Red LED flash every 53s
No sound
Test mode
Red LED flash quickly
Sound“Di-Di-Di”loudly
Alarm
Red LED flash quickly
Sound“Di-Di-Di”loudly
Silence mode
Red LED flash 1 time every 10 seconds
No sound
Low battery
Red LED flash 1 time every 53 seconds
Sound “Di” every 53 seconds
Fault
Red LED flash 2 times every 53 seconds
Sound “Di” twice every 53 seconds
13-How to replace the batteries
Turn right to dismantle the mounting base of the device
1) take out battery from the device2) Insert the battery into the device(You must be careful of the battery polarity)
Turn left to install the mounting base of the device(before install the mounting base, you should must insert battery firstly , otherwise the mounting base will not be fixed)