    TRACEABLE Full Scale Thermometer Instructions

    TRACEABLE Full Scale Thermometer Instructions ULTRA™ THERMOMETER ACCURACY Ultra™ thermometers are tested at selected test points to be within tighter than normal tolerances to assist in providing improved accuracy. Other points will not necessarily fall within the same accuracy as those found at the selected test points, but will be within an accuracy of ±1°C…

  • TRACEABLE Pocket Size Thermometer Instructions

    TRACEABLE Pocket Size Thermometer Instructions

    POCKET-SIZE™THERMOMETERINSTRUCTIONS SPECIFICATIONS Range: –50 to 1382°F (°F Model# 4232)–50 to 750°C (°C Model# 4233)Resolution: 1° THERMOCOUPLE The sensor supplied is a fast response beaded Type-K thermocouple. Maximum temperature for this sensor is 482 °F (250 °C), with shortterm usage to 572 °F (300 °C). Accessory thermocouples are available for measuring temperatures throughout the entire range…

  • TRACEABLE Solar-powered Thermometer Instructions

    TRACEABLE Solar-powered Thermometer Instructions

    TRACEABLE®SOLAR-POWEREDTHERMOMETERINSTRUCTIONS SPECIFICATIONS Display: ½” high 4-Digit LCDProbe Range: –58.0 to 158.0°F/–50.0 to 70.0°CResolution: 0.1°Accuracy: ±1°C (between –20 to 70°C) THERMOMETER To activate the battery, remove the insulating tape from the battery compartment. The battery is used to supply power to the unit during low light conditions. DISPLAYING °F OR °C Press the °C/°F switch to…

  • TRACEABLE Solar-powered Thermometer Instructions

    TRACEABLE Solar-powered Thermometer Instructions

    TRACEABLE®SOLAR-POWEREDTHERMOMETERINSTRUCTIONS SPECIFICATIONS Display: ½” high 4-Digit LCDProbe Range: –58.0 to 158.0°F/–50.0 to 70.0°CResolution: 0.1°Accuracy: ±1°C (between –20 to 70°C) THERMOMETER To activate the battery, remove the insulating tape from the battery compartment. The battery is used to supply power to the unit during low light conditions. DISPLAYING °F OR °C Press the °C/°F switch to…

  • TRACEABLE Radio-signal Remote Thermometer Instructions

    TRACEABLE Radio-signal Remote Thermometer Instructions

    TRACEABLE Radio-signal Remote Thermometer Instructions   SPECIFICATIONS Display—Main unit: two-line 1″ LCDRemote unit: 3/8″ LCD Temperature—Main unit IN range: –9.9 to 158.0°F (–9.9 to 70.0°C)Main unit OUT range: –58.0 to 158.0°F (–50.0 to 70.0°C)Main unit resolution: 0.1°Main unit accuracy: ±1.0°CMain unit ambient operating range: 23.0 to 122.0°F (–5.0 to 50.0°C)Remote unit OUT (probe): –50.0 to…

  • TRACEABLE 4377 Full-Scale Plus Thermometer Instructions

    TRACEABLE 4377 Full-Scale Plus Thermometer Instructions

    TRACEABLE 4377 Full-Scale Plus Thermometer Instructions SPECIFICATIONS: Display: ⅜” LCDRange: –58 to 572°F/–50 to 300°CResolution: 0.1° for –20.0° to 200.0° and 1.0° elsewhereAccuracy: Cat. No. 4377 – ±1.0°C between –20 to 100°C Cat. No. 4368 – ±0.5°C at tested points between –20 to 100°C ±1.0°C otherwise Sampling Rate: 1 secondFeatures: Clip and protective sleeve CONTROLS/INDICATORS…

  • TRACEABLE Infrared Forehead Thermometer with FDA Clearance Instructions

    TRACEABLE Infrared Forehead Thermometer with FDA Clearance Instructions

    TRACEABLE Infrared Forehead Thermometer with FDA Clearance Instructions FDA Cleared Noncontact Infrared Forehead Thermometer Stay safe—get precise forehead temperature measurements without physical contact Choose body or surface measurement mode for optimal accuracy Audible alarm alerts you to above-range readings Backlight display permits viewing in low-light conditions Features selectable °F/°C units, automatic data Hold, and auto…

  • TRACEABLE S04566 Memory Card Thermometer Instructions

    TRACEABLE S04566 Memory Card Thermometer Instructions

    TRACEABLE S04566 Memory Card Thermometer Instructions WARRANTY, SERVICE, OR RECALIBRATIONFor warranty, service, or recalibration, contact: TRACEABLE® PRODUCTS12554 Old Galveston Rd. Suite B230Webster, Texas 77598 USAPh. 281 482-1714 • Fax 281 482-9448E-mail [email protected] • www.traceable.comTraceable® Products is ISO 9001:2018 Quality-Certified by DNV and ISO/IEC 17025:2017accredited as a Calibration Laboratory by A2LA. Word® and Excel® are registered…

  • Traceable Bench Conductivity Meter Instructions

    Traceable Bench Conductivity Meter Instructions

    TRACEABLE®BENCHCONDUCTIVITYMETERW// AS-232 OUTPUTINSTRUCTIONS SpecificationMeter Conductivity Range:(range selecting automatic & manual) 0.01 to 19.99μS (micromhos)1 to 19.99 μS (micromhos)0.01 to 19.99 mS (mhos)0.1 to 199.9 mS (mhos) Accuracy: ±O.3% + 1 digit Resistivity Range: Megohms(range selecting automatic & manual) 0.001 to 1.999 Megohms0.01 to 19.99 Megohms Accuracy: ±0.3 % + 1 digit Total Dissolved Solids:(range selecting…

  • TRACEABLE Jumbo Thermometer Instructions

    TRACEABLE Jumbo Thermometer Instructions

    TRACEABLE® JUMBOTHERMOMETER INSTRUCTIONS SPECIFICATIONS Range: – –58.0 to 158.0°F / –50.0 to 70.0°CResolution:-  0.1°Update Rate: 10 secondsBattery: – AAA (1.5V) Probe Supplied: Model 4148– Supplied with a standard probe sensor with cable. Both sensor and cable may be immersed in liquid. The probe sensor may be mounted using the supplied sensor holder and mounting screw.…